Literature DB >> 27839605

Intraocular lens power formula accuracy: Comparison of 7 formulas.

Jack X Kane1, Anton Van Heerden2, Alp Atik2, Constantinos Petsoglou2.   

Abstract

PURPOSE: To assess the accuracy of 7 intraocular lens (IOL) power formulas (Barrett Universal II, Haigis, Hoffer Q, Holladay 1, Holladay 2, SRK/T, and T2) using IOLMaster biometry and optimized lens constants.
SETTING: Public hospital ophthalmology department.
DESIGN: Retrospective case series.
METHODS: Data from patients having uneventful cataract surgery with Acrysof IQ SN60WF IOL implantation over 5 years were obtained from the biometry and patient charts. Optimized lens constants were calculated for each formula and used to determine the predicted refractive outcome for each patient. This was compared with the actual refractive outcome to give the prediction error. Eyes were separated into subgroups based on axial length (AL) as follows: short (≤22.0 mm), medium (>22.0 to <24.5 mm), medium long (≥24.5 to <26.0 mm), and long (≥26.0 mm).
RESULTS: The study included 3241 patients. The Barrett Universal II formula had the lowest mean absolute prediction error over the entire AL range (P < .001, all formulas) as well as in the medium (P < .001, all formulas), medium-long (P < .001, except Holladay 1 and T2), and long AL (P < .001, except T2) subgroups. No statistically significant difference was seen between formulas in the short AL subgroup. Overall, the Barrett Universal II formula resulted in the highest percentage of eyes with prediction errors between ±0.25 diopter D, ±0.50 D, and ±1.00 D.
CONCLUSION: In eyes with an AL longer than 22.0 mm, the Barrett Universal II formula was a more accurate predictor of actual postoperative refraction than the other formulas. FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.
Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27839605     DOI: 10.1016/j.jcrs.2016.07.021

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  62 in total

Review 1.  Clinical application of accommodating intraocular lens.

Authors:  You-Ling Liang; Song-Bai Jia
Journal:  Int J Ophthalmol       Date:  2018-06-18       Impact factor: 1.779

2.  Predictability of intraocular lens power calculation in eyes after phototherapeutic keratectomy.

Authors:  Ryo Yoneyama; Kazutaka Kamiya; Kei Iijima; Masahide Takahashi; Nobuyuki Shoji
Journal:  Jpn J Ophthalmol       Date:  2019-11-05       Impact factor: 2.447

3.  Stability of the Barrett True-K formula for intraocular lens power calculation after SMILE in Chinese myopic eyes.

Authors:  Wei Zhu; Feng-Ju Zhang; Yu Li; Yan-Zheng Song
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

4.  Comparison of immersion ultrasound and low coherence reflectometry for ocular biometry in cataract patients.

Authors:  Yan Li; Hong-Xun Li; Yang-Chen Liu; Ya-Tu Guo; Jian-Min Gao; Bin Wu; Nan Zhang; Dong Liu; Xiao-Yong Yuan
Journal:  Int J Ophthalmol       Date:  2018-06-18       Impact factor: 1.779

5.  Comparing the accuracy of new intraocular lens power calculation formulae in short eyes after cataract surgery: a systematic review and meta-analysis.

Authors:  Yu Luo; Hongyu Li; Lixiong Gao; Jinlin Du; Wenqian Chen; Yi Gao; Zi Ye; Zhaohui Li
Journal:  Int Ophthalmol       Date:  2022-01-26       Impact factor: 2.031

6.  Prospective comparison of accuracy of intraocular lens calculation formulas in phacovitrectomy: a pilot study in a real-world clinical practice.

Authors:  Tatsuhiko Sato; Emiko Iimori; Ken Hayashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-07-25       Impact factor: 3.535

7.  Lower refractive prediction accuracy of total keratometry using intraocular lens formulas loaded onto a swept-source optical biometer.

Authors:  Yukitaka Danjo; Reina Ohji; Sayo Maeno
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-07-26       Impact factor: 3.535

8.  Comparing the accuracy of the new-generation intraocular lens power calculation formulae in axial myopic eyes: a meta-analysis.

Authors:  Hongyu Li; Zi Ye; Yu Luo; Zhaohui Li
Journal:  Int Ophthalmol       Date:  2022-09-05       Impact factor: 2.029

9.  Accuracy of intraocular lens power calculation in primary angle-closure disease: comparison of 7 formulas.

Authors:  Min Hou; Yujie Ding; Liangping Liu; Jianbing Li; Xing Liu; Mingxing Wu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-07-14       Impact factor: 3.117

Review 10.  Screening, genetics, risk factors, and treatment of neonatal cataracts.

Authors:  Jinyu Li; Chun-Hong Xia; Eddie Wang; Ke Yao; Xiaohua Gong
Journal:  Birth Defects Res       Date:  2017-05-22       Impact factor: 2.661

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.