Intraocular lens power calculations in short eyes using 7 formulas.

Sabite E Gökce1, John H Zeiter1, Mitchell P Weikert1, Douglas D Koch1, Warren Hill1, Li Wang2.   

Abstract

PURPOSE: To investigate the accuracy of 7 intraocular lens (IOL) calculation formulas in predicting refractive outcome in eyes with axial lengths (AL) equal to or less than 22.0 mm and to evaluate factors contributing to prediction errors.
SETTING: Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, and private practice, Mesa, Arizona, USA.
DESIGN: Retrospective case series.
METHODS: Eighty-six eyes of 67 patients were included. Seven IOL calculation formulas were evaluated: Barrett Universal II, Haigis, Hill-RBF, Hoffer Q, Holladay 1, Holladay 2, and Olsen. The refractive prediction error was calculated as the difference between the postoperative refraction and the refraction predicted by each formula. The mean refractive prediction error and median absolute error were also calculated.
RESULTS: The Hoffer Q and Holladay 2 formulas produced myopic refractive prediction errors of -0.22 diopter (D) and -0.23 D, respectively, and the Olsen formula produced a hyperopic refractive prediction error of +0.27 D (all P < .05). Without adjustment of the mean refractive prediction errors to zero, the only difference between formulas was that Hill-RBF had a statistically significantly smaller median absolute error than Hoffer Q (P < .05). With adjustment of the mean refractive prediction errors to zero, there were no statistically significant differences in the median absolute errors between the 7 formulas (P = .076).
CONCLUSIONS: The Hoffer Q and Holladay 2 formulas produced slightly myopic refractive prediction errors, and the Olsen formula produced hyperopic refractive prediction errors. When the mean numerical refractive prediction error was adjusted to zero, no statistically significant differences in the median absolute error were found between the 7 formulas.
Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28823434     DOI: 10.1016/j.jcrs.2017.07.004

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  16 in total

1.  Comparison of the Barrett Universal II, Kane and VRF-G formulas with existing intraocular lens calculation formulas in eyes with short axial lengths.

Authors:  Oleksiy V Voytsekhivskyy; Larysa Tutchenko; Diogo Hipólito-Fernandes
Journal:  Eye (Lond)       Date:  2022-01-15       Impact factor: 3.775

2.  Comparing the accuracy of new intraocular lens power calculation formulae in short eyes after cataract surgery: a systematic review and meta-analysis.

Authors:  Yu Luo; Hongyu Li; Lixiong Gao; Jinlin Du; Wenqian Chen; Yi Gao; Zi Ye; Zhaohui Li
Journal:  Int Ophthalmol       Date:  2022-01-26       Impact factor: 2.031

3.  Effectiveness, Sensitivity, and Specificity of Intraocular Lens Power Calculation Formulas for Short Eyes.

Authors:  Wiktor Stopyra
Journal:  Turk J Ophthalmol       Date:  2022-06-29

4.  Bilateral implantation of +56 and +58 diopter custom-made intraocular lenses in patient with extreme nanophthalmos.

Authors:  Tadas Naujokaitis; Debora Scharf; Isabella Baur; Ramin Khoramnia; Gerd U Auffarth
Journal:  Am J Ophthalmol Case Rep       Date:  2020-10-09

Review 5.  Recurring themes during cataract assessment and surgery.

Authors:  Shruti Chandra; Sobha Sivaprasad; Paul G Ursell; Khayam Naderi; David O'Brart; Amar Alwitry; Mayank A Nanavaty
Journal:  Eye (Lond)       Date:  2021-04-29       Impact factor: 4.456

6.  Effect of anterior chamber depth on predictive accuracy of seven intraocular lens formulas in eyes with axial length less than 22 mm.

Authors:  Ankur K Shrivastava; Pranayee Behera; Rajaram Kacher; Binod Kumar
Journal:  Clin Ophthalmol       Date:  2019-08-20

7.  Visual And Refractive Outcomes In Hyperopic Pseudophakic Patients Implanted With A Trifocal Intraocular Lens.

Authors:  José F Alfonso; Andrés Fernández-Vega-Cueto; Belén Alfonso-Bartolozzi; Ignacio Rodríguez-Uña; Robert Montés-Micó
Journal:  Clin Ophthalmol       Date:  2019-11-20

8.  Accuracy of intraocular lens power calculation formulas using a swept-source optical biometer.

Authors:  Se Young Kim; Seung Hyun Lee; Na Rae Kim; Hee Seung Chin; Ji Won Jung
Journal:  PLoS One       Date:  2020-01-14       Impact factor: 3.240

9.  Accuracy of theoretical IOL formulas for Panoptix intraocular lens according to axial length.

Authors:  Ayoung Choi; Hyunggoo Kwon; Sohee Jeon
Journal:  Sci Rep       Date:  2021-04-01       Impact factor: 4.379

10.  Risk Factor for Transient Hyperopic Refractive Outcome at Acute Postoperative Period After Panoptix Intraocular Lens Implantation.

Authors:  Sohee Jeon; Ayoung Choi
Journal:  Clin Ophthalmol       Date:  2021-06-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.