Literature DB >> 29498180

Accuracy of intraocular lens power calculation formulas in long eyes: a systematic review and meta-analysis.

Qiwei Wang1, Wu Jiang2, Tiao Lin3, Yi Zhu1,4, Chuan Chen1,4, Haotian Lin1, Weirong Chen1.   

Abstract

IMPORTANCE: Visual outcome after intraocular lens (IOL) implantation in long eyes is considerably affected by IOL power calculation. Various formulas have been designed to achieve an accurate IOL power prediction. However, controversy about the accuracy remains.
BACKGROUND: To evaluate the accuracy of IOL power calculation formulas in long eyes.
DESIGN: Meta-analysis. PARTICIPANTS: Patients with ocular axial length (AL) over 24.5 mm.
METHODS: A comprehensive search in PubMed, EMBASE, Cochrane Data Base of Systematic Reviews and the Cochrane Central Register of Controlled Trials were conducted by September, 2017. The weighted mean differences of mean absolute errors (MAE) and the odds ratio of percentage of eyes within ±0.50D of prediction error among formulas were analysed. MAIN OUTCOMES MEASURES: Between-group differences of MAE among formulas.
RESULTS: Eleven observational studies, involving 4047 eyes, were enrolled. Six formulas for IOL power calculation were compared: Barrett Universal II, Haigis, Holladay 2, SRK/T, Hoffer Q and Holladay 1. The MAE of Barrett Universal II was statistically lower than that of Holladay 2 (mean difference, MD = -0.04D, P = 0.0002), SRK/T (MD = -0.05D, P < 0.00001), Hoffer Q (MD = -0.07D, P < 0.00001) and Holladay 1 (MD = -0.07D, P < 0.00001). Barrett Universal II yielded significantly higher percentage of eyes within ±0.50D of the prediction error than the other formulas. The heterogeneity was minimized through dividing eyes into two groups by the AL of 26 mm. CONCLUSIONS AND RELEVANCE: This study demonstrates the superiority of Barrett Universal II over Holladay 2, SRK/T, Hoffer Q and Holladay 1 in predicting IOL power in long eyes.
© 2018 Royal Australian and New Zealand College of Ophthalmologists.

Entities:  

Keywords:  cataract; intraocular lens power; long eyes; mean absolute errors; prediction error

Mesh:

Year:  2018        PMID: 29498180     DOI: 10.1111/ceo.13184

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  14 in total

1.  Comparison of ocular parameters of two biometric measurement devices in highly myopic eyes.

Authors:  Xiao-Xiao Guo; Ran You; Shan-Shan Li; Xiu-Fen Yang; Lu Zhao; Fan Zhang; Yan-Ling Wang; Xi Chen
Journal:  Int J Ophthalmol       Date:  2019-10-18       Impact factor: 1.779

2.  Comparing the accuracy of the new-generation intraocular lens power calculation formulae in axial myopic eyes: a meta-analysis.

Authors:  Hongyu Li; Zi Ye; Yu Luo; Zhaohui Li
Journal:  Int Ophthalmol       Date:  2022-09-05       Impact factor: 2.029

3.  Algorithmic intraocular lens power calculation formula selection by keratometry, anterior chamber depth and axial length.

Authors:  Jung Wan Kim; Youngsub Eom; Eun Gyu Yoon; Young Choi; Jong Suk Song; Ji Won Jeong; Seh Kwang Park; Hyo Myung Kim
Journal:  Acta Ophthalmol       Date:  2021-08-11       Impact factor: 3.988

4.  Effectiveness, Sensitivity, and Specificity of Intraocular Lens Power Calculation Formulas for Short Eyes.

Authors:  Wiktor Stopyra
Journal:  Turk J Ophthalmol       Date:  2022-06-29

Review 5.  Recurring themes during cataract assessment and surgery.

Authors:  Shruti Chandra; Sobha Sivaprasad; Paul G Ursell; Khayam Naderi; David O'Brart; Amar Alwitry; Mayank A Nanavaty
Journal:  Eye (Lond)       Date:  2021-04-29       Impact factor: 4.456

6.  New Approach for the Calculation of the Intraocular Lens Power Based on the Fictitious Corneal Refractive Index Estimation.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Ana Tauste; David P Piñero
Journal:  J Ophthalmol       Date:  2019-05-14       Impact factor: 1.909

7.  Evaluation of the White-to-White Distance in 39,986 Chinese Cataractous Eyes.

Authors:  Ling Wei; Wenwen He; Jiaqi Meng; Dongjin Qian; Yi Lu; Xiangjia Zhu
Journal:  Invest Ophthalmol Vis Sci       Date:  2021-01-04       Impact factor: 4.799

8.  Effect of the ratio of axial length to keratometry on SRK/T intraocular lens power calculations for eyes with long axial lengths.

Authors:  Yosai Mori; Keiichiro Minami; Shota Tokuda; Jinhee Lee; Kazunori Miyata
Journal:  Sci Rep       Date:  2019-12-20       Impact factor: 4.379

9.  Correlating Kane formula with existing intraocular lens formulae for corneal curvatures and axial lengths.

Authors:  P Priji; Sajeev Cherian Jacob; Lavanya Kalikivayi; Venkataramana Kalikivayi
Journal:  Oman J Ophthalmol       Date:  2021-06-28

10.  Accuracy of the Barrett Universal II formula integrated into a commercially available optical biometer when using a preloaded single-piece intraocular lens.

Authors:  Hiroki Mieno; Osamu Hieda; Toshihide Ikeda; Shino Hayashi; Masatsugu Hashida; Kimiaki Urabe; Chie Sotozono
Journal:  Indian J Ophthalmol       Date:  2021-09       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.