| Literature DB >> 36114395 |
Juan José González-Badillo1,2, Luis Sánchez-Medina3, Juan Ribas-Serna2,4, David Rodríguez-Rosell5,6,7.
Abstract
For more than a century, many concepts and several theories and principles pertaining to the goals, organization, methodology and evaluation of the effects of resistance training (RT) have been developed and discussed between coaches and scientists. This cumulative body of knowledge and practices has contributed substantially to the evolution of RT methodology. However, a detailed and rigorous examination of the existing literature reveals many inconsistencies that, unless resolved, could seriously hinder further progress in our field. The purpose of this review is to constructively expose, analyze and discuss a set of anomalies present in the current RT methodology, including: (a) the often inappropriate and misleading terminology used, (b) the need to clarify the aims of RT, (c) the very concept of maximal strength, (d) the control and monitoring of the resistance exercise dose, (e) the existing programming models and (f) the evaluation of training effects. A thorough and unbiased examination of these deficiencies could well lead to the adoption of a revised paradigm for RT. This new paradigm must guarantee a precise knowledge of the loads being applied, the effort they involve and their effects. To the best of our knowledge, currently this can only be achieved by monitoring repetition velocity during training. The main contribution of a velocity-based RT approach is that it provides the necessary information to know the actual training loads that induce a specific effect in each athlete. The correct adoption of this revised paradigm will provide coaches and strength and conditioning professionals with accurate and objective information concerning the applied load (relative load, level of effort and training effect). This knowledge is essential to make rational and informed decisions and to improve the training methodology itself.Entities:
Keywords: Exercise monitoring; Level of effort; Periodization; Training effects; Training methodology; Velocity-based resistance training
Year: 2022 PMID: 36114395 PMCID: PMC9481798 DOI: 10.1186/s40798-022-00513-z
Source DB: PubMed Journal: Sports Med Open ISSN: 2198-9761
Fig. 1A real example showing changes in selected mechanical variables following an 8-week RT program. Changes from pre- (Pre) to post-training (Post) against a load of 20 kg in the bench press exercise are shown for a representative subject. The force–time (A), RFD–time (B), velocity–time (C) and power–time (D) curves were obtained using a force platform synchronized with a linear velocity transducer and sampling vertical force and bar velocity at 1,000 Hz. The x-axis values have been adjusted to best show the Pre-Post change in the different mechanical variables. Peak values of each variable are reported
Fig. 2Force application during a progressive loading test in the bench press exercise for a representative subject: A force–time curves obtained for each of the increasing loads used; B peak force values attained against each load. Data obtained from a force platform sampling vertical force at 1000 Hz
Fig. 3Three real examples of specific changes experienced in the load–velocity relationship following different RT interventions in the bench press exercise. A A 6.1% improvement in 1RM is accompanied by a consistent and similar increment in movement velocity against all loads used during the progressive loading test. B Despite no change in 1RM from Pre to Post, the subject was able to develop faster movement velocities (which were undoubtedly due to an increased force application) against low-to-moderate loads (20–70 kg). C An opposite example, showing a 4.6% improvement in 1RM together with increased velocities against medium and high loads (50–90 kg) but no improvements in the velocity developed against low loads (20–40 kg). Data from absolute loads common to both Pre and Post tests are shown. Velocity data obtained from a linear velocity transducer sampling bar velocity at 1000 Hz