Literature DB >> 27632258

Retention and Stability of Implant-Retained Mandibular Overdentures Using Different Types of Resilient Attachments: An In Vitro Study.

Moustafa Abdou ELsyad, Nora Nory Agha, Ahmed Ali Habib.   

Abstract

PURPOSE: The aim of this study was to evaluate and compare the retention and stability of mandibular implant overdentures using different types of resilient attachments.
MATERIALS AND METHODS: Two implant analogs were inserted in the canine areas of an acrylic edentulous mandibular model. A metal-reinforced experimental overdenture was constructed and connected to the implant analogs (on two occasions) using either resilient telescopic or Locator attachments. Locators were divided into three subgroups according to the degree of retention of the male nylon insert: Locator extra-light retention (blue insert), Locator light retention (pink insert), and Locator medium retention (transparent insert). Vertical and oblique (anterior, posterior, and lateral) dislodging forces were measured at the beginning of the study (initial retention) and after 540 cycles of denture insertion and removal (final retention).
RESULTS: For all dislodging forces, Locator medium recorded the highest initial and final retention. Telescopic attachments recorded the lowest retention during vertical and anterior dislodging, and Locator extra-light recorded the lowest retention during lateral and posterior dislodging. For all types of Locator attachments, anterior dislodging recorded the highest initial and final retention, and lateral dislodging recorded the lowest retention. For the telescopic attachment, posterior dislodgment recorded the highest initial and final retention, and anterior dislodging recorded the lowest retention.
CONCLUSION: After repeated denture insertions and removals, the highest retention and stability were recorded with Locator medium followed by Locator light. The lowest retention was recorded with resilient telescopic attachment, and the lowest stability was recorded with Locator extra-light.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27632258     DOI: 10.11607/jomi.4544

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  4 in total

1.  Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element study.

Authors:  Angel Alvarez-Arenal; Ignacio Gonzalez-Gonzalez; Hector deLlanos-Lanchares; Elena Martin-Fernandez; Aritza Brizuela-Velasco; Joseba Ellacuria-Echebarria
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

2.  Patients' Satisfaction and Oral Health-Related Quality of Life of Edentulous Patients Using Conventional Complete Dentures and Implant-Retained Overdentures in Saudi Arabia.

Authors:  Salwa Omar Bajunaid; Abdullah S Alshahrani; Ahad A Aldosari; Atheer N Almojel; Rehab S Alanazi; Tala M Alsulaim; Syed Rashid Habib
Journal:  Int J Environ Res Public Health       Date:  2022-01-04       Impact factor: 3.390

3.  Comparison of Retention of Two Different Attachment Systems Used in Implant-Supported Overdentures.

Authors:  S Dhamodaran; Shafath Ahmed; Vidyashree Nandini; Russia Marimuthu; Sethuraman Ramadoss
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13

4.  An In vitro Assessment of Retention Force of ZrO2, Polyether Ether Ketone, and ZrO2-Polyether Ether Ketone Telescopic Attachment for Mandibular Overdentures.

Authors:  Siba Prasad Jena; Nimisha Kumari; Sumeet Agarwal; V A Afzal; Swaroopkumar M Magar; Prerna Gulati
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13
  4 in total