Literature DB >> 28387994

Locator Versus Bar Attachment Effect on the Retention and Stability of Implant-Retained Maxillary Overdenture: An In Vitro Study.

Moustafa Abdou ELsyad1, Mahmoud Abdehamid Dayekh1,2, Ahmed Khalifa Khalifa1.   

Abstract

PURPOSE: To compare retention and stability of Locator and bar attachments for implant-retained maxillary overdentures.
MATERIALS AND METHODS: Four implants were inserted into a maxillary acrylic resin model in canines and second premolar areas. Experimental overdentures were connected to the implants with bar (group I) or Locator (group II) attachments. Locators were divided into 3 subgroups according the degree of retention of the patrix nylon insert: Locator blue (group IIa), Locator pink (group IIb), and Locator transparent (group IIc). Retention (vertical dislodging) and stability (lateral, anterior, posterior dislodging) forces (N) were measured at the start of the experiment (initial retention) and after 540 cycles of denture insertion and removal (final retention).
RESULTS: The highest initial and final stability was recorded with group IIc, followed by group IIb and group IIa, and the lowest retention and stability was noted with group I. For all groups, the highest final retention and stability forces were noted with vertical dislodging, followed by posterior dislodging, anterior dislodging, and lateral dislodging. The highest loss of retention and stability was recorded with group I, followed by group IIc, group IIb, and group IIa.
CONCLUSION: Locator attachments are recommended to retain maxillary overdentures over Dolder bar attachments, as Locator attachments were associated with high retention and stability after wear simulation with minimal retention loss.
© 2017 by the American College of Prosthodontists.

Entities:  

Keywords:  Implant; bar; locator; maxillary; overdenture; retention; stability

Mesh:

Year:  2017        PMID: 28387994     DOI: 10.1111/jopr.12608

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  6 in total

1.  Patient satisfaction and survival of maxillary overdentures supported by four or six splinted implants: a systematic review with meta-analysis.

Authors:  Fabrizio Di Francesco; Emilio A Cafferata; Gennaro De Marco; Estefani B Capcha; Alessandro Lanza; Corina M Cristache; Rolando Vernal
Journal:  BMC Oral Health       Date:  2021-05-08       Impact factor: 2.757

2.  Implant-assisted removable prosthetic rehabilitation after distraction osteogenesis in a patient with ameloblastoma recurrence: A case report.

Authors:  Jae-Hyun Lee; Sung-Hun Kim; Hyung-In Yoon; In-Sung Luke Yeo; Jung-Suk Han
Journal:  Medicine (Baltimore)       Date:  2019-12       Impact factor: 1.889

3.  Bond strength of locator housing attached to denture base resin secured with different retaining materials.

Authors:  Mohammadreza Nakhaei; Hossin Dashti; Atefe Baghbani; Zahra Ahmadi
Journal:  Dent Res J (Isfahan)       Date:  2020-01-21

4.  How the initial retentive force of implant-supported overdentures can be affected with splinted and unsplinted attachments systems.

Authors:  Farahnaz Nejatidanesh; Omid Savabi; Ghazal Savabi; Mehdi Razavi
Journal:  Dent Res J (Isfahan)       Date:  2021-12-10

5.  Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar.

Authors:  Sung-Ki Chae; Won-Tak Cho; Jae-Won Choi; Eun-Bin Bae; Ji-Hyeon Bae; Gang-Ho Bae; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2022-02-25       Impact factor: 1.904

6.  Comparison of Retention of Two Different Attachment Systems Used in Implant-Supported Overdentures.

Authors:  S Dhamodaran; Shafath Ahmed; Vidyashree Nandini; Russia Marimuthu; Sethuraman Ramadoss
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.