SAPIEN 3 transcatheter heart valve in patients with borderline annulus: "stretched better than bigger?"

Giuseppe Tarantini1, Francesco Cardaioli1.   

Abstract

Entities:  

Mesh:

Year:  2022        PMID: 36084187      PMCID: PMC9543330          DOI: 10.1002/ccd.30372

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.585


× No keyword cloud information.
Transcatheter aortic valve replacement (TAVR) has become the treatment of choice in older and high‐surgical risk patients with aortic stenosis. At present, different valve types with different sizes are available, allowing optimal TAVR performance and clinical outcome in a wide range of patients. Selection of valve size (and type) that best fits the individual patient is mandatory as a patient‐specific or ‐tailored approach ensures higher procedural safety and efficacy. Currently, computed tomography scan of the heart is the standard and recommended imaging technique for valve's size selection. However, patients with borderline annular dimensions remains a particularly challenging setting. Different approaches have been proposed in this setting, such as the implantation of an undersized overexpanded (OE) device or the implantation of a nominally sized valve. Nevertheless, currently there is no consensus on what is be the most advisable implantation strategy in these patients. In this issue of catheterization and cardiovascular interventions, Basman et al. performed an observational study, comparing postprocedural outcomes of 336 patients with borderline annuli treated with balloon expandable (BE) Sapien 3 Ultra transcatheter heart valves (THVs), using either OE undersized devices or nominally sized valves (OE: 20 vs. 23 mm, N = 10 vs. 47; OE: 23 vs. 26 mm, N = 74 vs. 81; OE: 26 vs. 29 mm, N = 62 vs. 62). About 40% of patients overall underwent annular predilation before valve implantation. The authors found a significant reduction of the primary composite outcome (in‐hospital mortality, aortic injury, moderate/severe paravalvular leak [PVL], permanent pacemaker implant [PPM], stroke, or conversion to surgery) when an OE undersized device was used. This reduction in adverse outcomes was mainly driven by results observed in the OE 26 mm group compared with the 29 mm THVs (p = 0.02), while no significant differences were found in the other two groups. Among the individual components of the primary endpoint, PPM rate was numerically the main driver of the combined outcome difference observed. Though some previous studies have already reported the efficacy and feasibility of OE undersized BE device implantation, this is the very first paper comparing this strategy with a standard nominal‐device technique, showing some possible advantages of using smaller devices in borderline situations. Furthermore, previous studies were mostly represented by bench tests analyses and small case series involving patients with very large annuli treated with 29 mm BE‐OE devices. , Granted that, we should acknowledge that several anatomical characteristics, which may have been important to the final THV size (such as the presence, severity, and distribution of aortic valve calcifications, the sino‐tubular junction width and the annulus eccentricity) and relevant to patient's outcome, are not reported. Similarly, nothing is known about the implantation height and the balloon size for predilation or postdilation, which are well‐known determinants for PPM rate. Additionally, the present analysis was focused on BE valve type with the use of Sapien 3 Ultra device for 20–23 and 26 mm sizes but Sapien 3 for the 29 mm one. Thus, we cannot exclude that the use of two different platforms (with different frame height and different skirts) in the larger annuli subgroup (OE: 26 vs. 29 mm), may also have played a role in the observed results. The last consideration is that the present study had a follow‐up of 1 year. Despite the observed good and comparable 1‐year echocardiographic results of the two groups, longer observations are needed to evaluate the impact of OE THVs choice on both prosthesis performance and clinical outcome of the patients. In conclusion, the results of the current study remain to be proven by appropriately designed randomized studies. Given the rapid development of valve technologies, in the future, it will be important to have reliable bench test on how much bigger each valve type can be stretched. Moreover, a well‐designed study comparing physician versus simulation‐driven valve size and type selection (which must imply that the software keeps track of the novel valve technologies and sizes) may be also an interesting test. To this regards, patient‐specific computer simulation may add an important clinical value in cases of uncertainty in valve size selection (for instance due to the strict sizing criteria proposed by the manufacturer in combination with observer variability in CT scan analysis), allowing to refine the choice for a specific THV that best fits the individual patient.

CONFLICT OF INTEREST

The authors declare no conflict of interest.
  4 in total

1.  In-hospital and thirty-day outcomes of the SAPIEN 3 Ultra balloon-expandable transcatheter aortic valve: the S3U registry.

Authors:  Francesco Saia; Caterina Gandolfo; Tullio Palmerini; Sergio Berti; Sagar N Doshi; Mika Laine; Chiara Marcelli; Tommaso Piva; Flavio Ribichini; Mauro De Benedictis; Francesco Cardaioli; Stefano Cannata; Giuseppe Tarantini
Journal:  EuroIntervention       Date:  2020-02-20       Impact factor: 6.534

2.  Anatomical Predictors of Pacemaker Dependency After Transcatheter Aortic Valve Replacement.

Authors:  Luca Nai Fovino; Alberto Cipriani; Tommaso Fabris; Mauro Massussi; Andrea Scotti; Giulia Lorenzoni; Maria Chiara Guerra; Francesco Cardaioli; Giulio Rodinò; Yuji Matsuda; Giulia Masiero; Loira Leoni; Alessandro Zorzi; Chiara Fraccaro; Giuseppe Tarantini
Journal:  Circ Arrhythm Electrophysiol       Date:  2020-12-11

3.  Overexpansion of the SAPIEN 3 Transcatheter Heart Valve: An Ex Vivo Bench Study.

Authors:  Janarthanan Sathananthan; Stephanie Sellers; Aaron Barlow; Rob Fraser; Viktória Stanová; Anson Cheung; Jian Ye; Abdullah Alenezi; Dale J Murdoch; Mark Hensey; Danny Dvir; Philipp Blanke; Régis Rieu; David Wood; Phillippe Pibarot; Jonathan Leipsic; John Webb
Journal:  JACC Cardiovasc Interv       Date:  2018-09-10       Impact factor: 11.195

4.  Overexpansion of the 29 mm SAPIEN 3 transcatheter heart valve in patients with large aortic annuli (area > 683 mm2 ): A case series.

Authors:  Moses Mathur; James M McCabe; Gabriel Aldea; Jay Pal; Creighton W Don
Journal:  Catheter Cardiovasc Interv       Date:  2017-08-24       Impact factor: 2.692

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.