Literature DB >> 33306415

Anatomical Predictors of Pacemaker Dependency After Transcatheter Aortic Valve Replacement.

Luca Nai Fovino1, Alberto Cipriani1, Tommaso Fabris1, Mauro Massussi1, Andrea Scotti1, Giulia Lorenzoni1, Maria Chiara Guerra1, Francesco Cardaioli1, Giulio Rodinò1, Yuji Matsuda1, Giulia Masiero1, Loira Leoni1, Alessandro Zorzi1, Chiara Fraccaro1, Giuseppe Tarantini1.   

Abstract

BACKGROUND: Conduction disturbances after transcatheter aortic valve replacement (TAVR) are often transient. Limited data exist on anatomic factors predisposing to pacemaker dependency after TAVR. We sought to assess the rate and the possible predictors of pacemaker dependency after TAVR.
METHODS: Consecutive patients undergoing pacemaker implantation up to 30 days after TAVR between May 2014 and September 2019 were included. Baseline electrocardiographic, computed tomography, and procedural characteristics were collected, including valve implantation depth and membranous septum length, an anatomic surrogate of the distance between the aortic annulus and the His bundle. Pacemaker dependency at 30 days and 1 year and all-cause mortality during follow-up were evaluated.
RESULTS: Of 728 TAVR patients, 112 (53.5% men; median age, 81 years) underwent pacemaker implantation after TAVR. Of these, 44.6% (50 of 112) were pacemaker dependent at 30 days and 46.7% (36 of 77) at 1 year. By multivariate analysis, independent predictors of 30-day pacemaker dependency included left ventricular outflow tract calcifications under the left coronary cusp (odds ratio, 5.69 [95% CI, 1.45-22.31]; P=0.013) and a difference between membranous septum length and implantation depth (ΔMSID) ≥3 mm (odds ratio, 7.58 [95% CI, 2.07-27.78]; P=0.002). Conversely, membranous septum length and implantation depth alone were not associated with pacemaker dependency (odds ratio, 0.79 [95% CI, 0.60-1.05]; P=0.11 and odds ratio, 1.11 [95% CI, 0.99-1.24]; P=0.08). At a median follow-up of 28.1 (11.7-48.6) months, pacemaker-dependent patients did not show a worse survival (P=0.26).
CONCLUSIONS: Less than half of the patients undergoing pacemaker implantation after TAVR are pacemaker-dependent at midterm follow-up. ΔMSID ≥3 mm and the presence of left ventricular outflow tract calcifications under the left coronary cusp, but not membranous septum length nor implantation depth alone, are predictive of long-term pacemaker dependency after TAVR, thus influencing device selection and programming.

Entities:  

Keywords:  aortic valve; atrioventricular block; child; follow-up studies; multivariate analysis

Year:  2020        PMID: 33306415     DOI: 10.1161/CIRCEP.120.009028

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  4 in total

1.  10-Year Impact of Transcatheter Aortic Valve Replacement Leaflet Design (Intra- Versus Supra-Annular) in Mortality and Hemodynamic Performance.

Authors:  Andrea Scotti; Luca Nai Fovino; Augustin Coisne; Tommaso Fabris; Francesco Cardaioli; Mauro Massussi; Giulio Rodinò; Alberto Barolo; Mauro Boiago; Saverio Continisio; Carolina Montonati; Tommaso Sciarretta; Vittorio Zuccarelli; Valentina Bernardini; Giulia Masiero; Massimo Napodano; Chiara Fraccaro; Alfredo Marchese; Giovanni Esposito; Juan F Granada; Azeem Latib; Sabino Iliceto; Giuseppe Tarantini
Journal:  Front Cardiovasc Med       Date:  2022-06-08

Review 2.  Evolving Devices and Material in Transcatheter Aortic Valve Replacement: What to Use and for Whom.

Authors:  Mauro Chiarito; Alessandro Spirito; Johny Nicolas; Alexandra Selberg; Giulio Stefanini; Antonio Colombo; Bernhard Reimers; Annapoorna Kini; Samin K Sharma; George D Dangas; Roxana Mehran
Journal:  J Clin Med       Date:  2022-07-30       Impact factor: 4.964

3.  Atrioventricular conduction in PM recipients after transcatheter aortic valve implantation: Implications using Wenckebach point measurement.

Authors:  Gemma Pelargonio; Roberto Scacciavillani; Luca Donisi; Maria Lucia Narducci; Cristina Aurigemma; Gaetano Pinnacchio; Gianluigi Bencardino; Francesco Perna; Francesco Raffaele Spera; Gianluca Comerci; Eleonora Ruscio; Enrico Romagnoli; Filippo Crea; Francesco Burzotta; Carlo Trani
Journal:  Front Cardiovasc Med       Date:  2022-07-22

4.  SAPIEN 3 transcatheter heart valve in patients with borderline annulus: "stretched better than bigger?"

Authors:  Giuseppe Tarantini; Francesco Cardaioli
Journal:  Catheter Cardiovasc Interv       Date:  2022-09       Impact factor: 2.585

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.