Literature DB >> 31763985

In-hospital and thirty-day outcomes of the SAPIEN 3 Ultra balloon-expandable transcatheter aortic valve: the S3U registry.

Francesco Saia1, Caterina Gandolfo, Tullio Palmerini, Sergio Berti, Sagar N Doshi, Mika Laine, Chiara Marcelli, Tommaso Piva, Flavio Ribichini, Mauro De Benedictis, Francesco Cardaioli, Stefano Cannata, Giuseppe Tarantini.   

Abstract

AIMS: The aim of this study was to evaluate 30-day safety and efficacy outcomes of transcatheter aortic valve implantation (TAVI) performed with the SAPIEN 3 Ultra system. METHODS AND
RESULTS: The S3U registry is a physician-led, post-approval, multicentre, observational registry of transfemoral TAVI with the SAPIEN 3 Ultra. New features include an improved sealing skirt, a 14 Fr expandable sheath and a new delivery catheter. Overall, 139 consecutive patients at nine participating centres were enrolled. Mean age was 81.4±8.3 years, average STS score 3.8±2.4%. The vast majority (97.2%) underwent TAVI with local anaesthesia (28.8%) or conscious sedation (68.3%). Balloon predilatation was performed in 30 patients (21.6%), post-dilatation in three (2.2%). In-hospital, there were no cases of death, stroke, or conversion to open heart surgery. Major vascular complications occurred in three patients (2.2%), as well as major or life-threatening bleedings in three patients (2.2%). There were two moderate (1.4%) and no moderate/severe paravalvular leaks. Median length of stay after TAVI was three days (IQR 3-5 days). At 30 days, there were no deaths, MI, or strokes, and the incidence of new permanent pacemaker implantation was 4.4%.
CONCLUSIONS: This first multicentre international experience of transfemoral TAVI with the SAPIEN 3 Ultra transcatheter heart valve shows good in-hospital and 30-day clinical outcomes.

Entities:  

Mesh:

Year:  2020        PMID: 31763985     DOI: 10.4244/EIJ-D-19-00541

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  8 in total

1.  Early commercial experience with a newly designed balloon-expandable transcatheter heart valve: 30-day outcomes and implications of preprocedural computed tomography.

Authors:  Andreas Schaefer; Fabienne Plassmeier; Niklas Schofer; Lukas Vogel; Sebastian Ludwig; Yvonne Schneeberger; Matthias Linder; Till Demal; Moritz Seiffert; Stefan Blankenberg; Hermann Reichenspurner; Dirk Westermann; Lenard Conradi
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-04-08

2.  Incidence and predictors of prosthesis-patient mismatch after TAVI using SAPIEN 3 in Asian: differences between the newer and older balloon-expandable valve.

Authors:  Masaki Miyasaka; Norio Tada; Masataka Taguri; Shigeaki Kato; Yusuke Enta; Masaki Hata; Yusuke Watanabe; Toru Naganuma; Masahiro Yamawaki; Futoshi Yamanaka; Shinichi Shirai; Hiroshi Ueno; Kazuki Mizutani; Minoru Tabata; Kensuke Takagi; Masanori Yamamoto; Kentaro Hayashida
Journal:  Open Heart       Date:  2021-03

3.  Minimizing Paravalvular Regurgitation With the Novel SAPIEN 3 Ultra TAVR Prosthesis: A Real-World Comparison Study.

Authors:  Alexander R Tamm; Michaela M Hell; Martin Geyer; Felix Kreidel; Jaqueline G da Rocha E Silva; Meike Seidl; Tobias F Ruf; Angela Kornberger; Andres Beiras-Fernandez; Thomas Münzel; Ralph Stephan von Bardeleben
Journal:  Front Cardiovasc Med       Date:  2021-03-18

4.  The Technological Basis of a Balloon-Expandable TAVR System: Non-occlusive Deployment, Anchorage in the Absence of Calcification and Polymer Leaflets.

Authors:  Harish Appa; Kenneth Park; Deon Bezuidenhout; Braden van Breda; Bruce de Jongh; Jandré de Villiers; Reno Chacko; Jacques Scherman; Chima Ofoegbu; Justiaan Swanevelder; Michael Cousins; Paul Human; Robin Smith; Ferdinand Vogt; Bruno K Podesser; Christoph Schmitz; Lenard Conradi; Hendrik Treede; Holger Schröfel; Theodor Fischlein; Martin Grabenwöger; Xinjin Luo; Heather Coombes; Simon Matskeplishvili; David F Williams; Peter Zilla
Journal:  Front Cardiovasc Med       Date:  2022-03-03

5.  SAPIEN 3 transcatheter heart valve in patients with borderline annulus: "stretched better than bigger?"

Authors:  Giuseppe Tarantini; Francesco Cardaioli
Journal:  Catheter Cardiovasc Interv       Date:  2022-09       Impact factor: 2.585

6.  Hemodynamic comparison of transcatheter aortic valve replacement with the SAPIEN 3 Ultra versus SAPIEN 3: The HomoSAPIEN registry.

Authors:  Noriaki Moriyama; Heidi Lehtola; Hirokazu Miyashita; Jarkko Piuhola; Matti Niemelä; Mika Laine
Journal:  Catheter Cardiovasc Interv       Date:  2020-09-23       Impact factor: 2.692

Review 7.  Update on Transcatheter Aortic Valve Replacement.

Authors:  Morgan H Randall; Anthony A Bavry
Journal:  Cardiol Ther       Date:  2020-02-28

Review 8.  Choice of transcatheter heart valve: should we select the device according to each patient's characteristics or should it be "one valve fits all"?

Authors:  Matthias Renker; Won-Keun Kim
Journal:  Ann Transl Med       Date:  2020-08
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.