| Literature DB >> 36068603 |
Belén Alfonso-Bartolozzi1, Carlos Lisa1, Luis Fernández-Vega-Cueto2, Begoña Baamonde1, David Madrid-Costa3, José F Alfonso1.
Abstract
BACKGROUND: To evaluate clinical outcomes of the Visian implantable collamer lens (ICL) with a central port to correct myopia and astigmatism after deep anterior lamellar keratoplasty (DALK) for keratoconus throughout 3 years of follow-up.Entities:
Keywords: DALK; Deep anterior lamellar keratoplasty; ICL; Implantable collamer lens
Year: 2022 PMID: 36068603 PMCID: PMC9450313 DOI: 10.1186/s40662-022-00306-1
Source DB: PubMed Journal: Eye Vis (Lond) ISSN: 2326-0254
Preoperative patient demographics and ICL characteristics
| Mean ± SD | Range (min, max) | |
|---|---|---|
| Age (years) | 39.85 ± 10.40 | (25, 62) |
| Refraction sphere (D) | − 5.78 ± 3.87 | (− 15.00, − 0.50) |
| Refraction cylinder (D) | − 2.36 ± 1.40 | (− 5.00, − 0.50) |
| Spherical equivalent (D) | − 6.96 ± 3.89 | (− 16.13, − 2.25) |
| Minimum keratometry (D) | 43.95 ± 2.00 | (40.75, 48.00) |
| Maximum keratometry (D) | 46.78 ± 2.19 | (42.25, 51.00) |
| Keratometric cylinder (D) | 2.83 ± 1.57 | (1.00, 6.00) |
| Corneal thickness (μm) | 507 ± 64 | (407, 581) |
| ACD (mm) | 3.49 ± 0.25 | (3.00, 3.93) |
| WTW (mm) | 12.26 ± 0.48 | (11.45, 13.27) |
| ATA (mm) | 11.94 ± 0.42 | (11.00, 13.20) |
| ECD (cells/mm2) | 2173 ± 533 | (1527, 3347) |
| IOP (mmHg) | 12.65 ± 1.66 | (10, 16) |
| ICL sphere power (D) | − 7.93 ± 3.98 | (− 16.50, − 3.50) |
| ICL toric power (D)* | 4.36 ± 0.99 | (3.50, 6.00) |
ICL = implantable collamer lens; D = diopters; ACD = anterior chamber depth; WTW = white-to-white; ATA = angle-to-angle; ECD = endothelial cell density; IOP = intraocular pressure; SD = standard deviation. *For 7 eyes that were implanted with a toric ICL
Fig. 1Cumulative uncorrected distance visual acuity (UDVA) (a), and corrected distance visual acuity (CDVA) (b), at 6, 12 and 36 months post-surgery. c Changes in CDVA between preoperative and each postoperative visit
Fig. 2Attempted versus achieved spherical equivalent at 6 months postoperatively (predictability) (a), variation of manifest spherical equivalent over the follow-up (stability) (b), and accuracy of manifest spherical equivalent at each postoperative follow-up visit
Fig. 3Changes in the mean intraocular pressure (IOP) over the whole follow-up (a), and variation in IOP between preoperative and each postoperative follow-up visit (b)
Fig. 4Mean endothelial cell density (ECD) (cells/mm2) throughout the follow-up
Fig. 5Distribution of eyes according to the vault, measured in microns, at 6, 12, and 36 months postoperatively