Tomasz A Timek1,2. 1. Division of Cardiothoracic Surgery, Spectrum Health, Grand Rapids, Mich. 2. Michigan State University College of Human Medicine, East Lansing, Mich.
Tomasz A. Timek, MD, PhDPacemaker implantation after cardiac surgery may not independently affect 5-year survival.See Article page 157.Permanent pacemaker (PPM) insertion is a well-recognized complication of valvular surgery, with an incidence of 4%-51% depending on the type and number of valves replaced and surgical versus transcatheter approach., Although device insertion is needed for chronotropic support of cardiac function, the long-term complications of paced physiology and device-related morbidities are still being examined. Some studies suggest decreased long-term survival with postoperative PPM insertion,, whereas others do not confirm these trends. A propensity-matched analysis of more than 24,000 patients from the Taiwan National Insurance Research Database revealed that PPM implantation may affect long-term mortality based on the site of valve surgery or combination of implanted valves. Furthermore, pacemaker dependency after device implantation may also play an important role in distant survival. The work by Bianco and colleagues from the University of Pittsburgh presented in the current issue of the Journal adds valuable data to this controversy and suggests that when adjusted for patient characteristics, PPM implantation after isolated valve or valve and coronary surgery does not affect distal survival. Although the authors present a large clinical cohort, the results and conclusions of the study need to be evaluated through a prism of several methodologic limitations.Right ventricular pacing has been shown to lead to pacing-induced heart disease, adverse remodeling, and heart failure, with clinical consequence usually seen after more than 3 years of ventricular pacing. Similarly, the rate of device-related complications such as lead fracture or endocarditis accumulate over time, resulting in up to 10% of all implanted leads needing eventual replacement. Data from a US Extraction Database reported a 1.4% major complication rate in an extraction of 3540 leads at a mean of 47 ± 41 months after implantation. The follow-up in the current study extends mostly up to 5 years from time of operation and therefore may not fully capture the morbidity and potential mortality associated with PPM in the long term. In the current study, neither the rate of pacemaker infection nor lead replacement was reported. A similarly sized study from the Mayo Clinic of PPM implantation after aortic valve replacement with a median follow-up of 11.1 years revealed that device implantation was associated with increased risk of death even after multivariate adjustment of baseline patient characteristics. Indeed, in the adjusted analysis, the survival curves appeared to diverge more clearly after 5 years. The conclusion of the study by Bianco and colleagues hinges on a risk-adjusted population, but although the investigators present a large clinical cohort, propensity matching was not feasible and hence adjustment for baseline characteristics, although statistically rigorous, incomplete. The authors enrolled only patients with aortic or mitral valve procedure, and no double- or triple-valve surgeries were included. However, these more complex patients have greater risk profiles and rates of PPM implantation, which may further exacerbate baseline ventricular dysfunction and congestive symptoms. As such, extrapolation of the current data to all-encompassing valve surgery should be approached with restraint. Rhythm disturbances are a rare but real consequence of valvular surgery that are unlikely to be mitigated by percutaneous techniques. Surgical teaching dictates that nothing is without consequence, and the need for a pacing device implantation after valve procedures should be viewed through the same lens for both surgical and transcatheter valve approaches. How consequential of a procedure PPM implantation will become, only time and rigorous follow-up will demonstrate.
Authors: Kevin L Greason; Brian D Lahr; John M Stulak; Yong-Mei Cha; Robert F Rea; Hartzell V Schaff; Joseph A Dearani Journal: Ann Thorac Surg Date: 2017-04-19 Impact factor: 4.330
Authors: J Hunter Mehaffey; Nathan S Haywood; Robert B Hawkins; John A Kern; Nicholas R Teman; Irving L Kron; Leora T Yarboro; Gorav Ailawadi Journal: Ann Thorac Surg Date: 2018-03-22 Impact factor: 4.330
Authors: C L Byrd; B L Wilkoff; C J Love; T D Sellers; K T Turk; R Reeves; R Young; B Crevey; S P Kutalek; R Freedman; R Friedman; J Trantham; M Watts; J Schutzman; J Oren; J Wilson; F Gold; N E Fearnot; H J Van Zandt Journal: Pacing Clin Electrophysiol Date: 1999-09 Impact factor: 1.976
Authors: Michael P Robich; Nicholas K Schiltz; Douglas R Johnston; Stephanie Mick; Amar Krishnaswamy; Rodrigo A Iglesias; Dustin Hang; Eric E Roselli; Edward G Soltesz Journal: J Card Surg Date: 2016-06-22 Impact factor: 1.620
Authors: George C M Siontis; Peter Jüni; Thomas Pilgrim; Stefan Stortecky; Lutz Büllesfeld; Bernhard Meier; Peter Wenaweser; Stephan Windecker Journal: J Am Coll Cardiol Date: 2014-07-15 Impact factor: 24.094