Yuito Abe1,2, Takashi Omoto3, Kohdai Kitamoto1, Tetsuya Toyono1, Junko Yoshida4, Ryo Asaoka5, Satoru Yamagami6, Takashi Miyai1, Tomohiko Usui4.
Abstract
The purpose of this study was to evaluate corneal irregular astigmatism of patients with granular and lattice corneal dystrophy (GCD and LCD). 70 GCD, 35 LCD, and 81 control eyes were included. Anterior and posterior corneal topographic data obtained from anterior segment optical coherence tomography were expanded into four components via Fourier harmonic analysis. These components were compared with healthy eyes and the association between each component and best-corrected visual acuity (BCVA) was investigated. Anterior and posterior components increased in both GCD and LCD eyes. Anterior and posterior components of GCD2, anterior of LCD type 1 (LCD1), posterior of LCD type IIIA (LCD 3A), and type IV (LCD4) significantly increased. BCVA was significantly associated with anterior and posterior components in LCD eyes but not in GCD. The anterior components of LCD1, anterior and posterior of LCD3A, and posterior of LCD4 , were positively correlated with BCVA. As conclusions, in GCD eyes, anterior and posterior components differed from those of the control but BCVA was not significantly associated with them. In LCD eyes, the anterior and posterior components increased, and BCVA was significantly associated with the anterior and posterior components.Entities:
Mesh:
Year: 2022 PMID: 35962009 PMCID: PMC9374664 DOI: 10.1038/s41598-022-17738-3
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.996
Demographic characteristics of the participants.
| Controls | GCD | LCD | ||||
|---|---|---|---|---|---|---|
| GCD2 | LCD (Total) | LCD1 | LCD3A | LCD4 | ||
| No. of eyes (patients) | 81 (58) | 66 (35) | 35 (21) | 11 (7) | 11 (6) | 13 (8) |
| Age (years) | 66.3 ± 9.5 | 60.4 ± 16.8* | 66.9 ± 14.9 | 51.1 ± 13.7* | 75.8 ± 7.8* | 72.6 ± 9.9* |
| Sex (male/female) | 41/40 | 26/40 | 24/11 | 6/5 | 9/2* | 9/4 |
| IOL eyes | 0 | 14 | 10 | 2 | 5 | 3 |
| BCVA (LogMAR) | − 0.061 ± 0.034 | 0.17 ± 0.23* | 0.52 ± 0.51* | 0.69 ± 0.58* | 0.30 ± 0.20* | 0.56 ± 0.56* |
GCD: Granular corneal dystrophy, GCD1: Granular corneal dystrophy type 1, GCD2: Granular corneal dystrophy type 2, LCD: Lattice corneal dystrophy, LCD1: Lattice corneal dystrophy type 1, LCD3A: Lattice corneal dystrophy type IIIA, LCD4: Lattice corneal dystrophy type IV, IOL: Intraocular lens, BCVA: Best-corrected visual acuity. Values were shown in mean ± standard deviation manner.
p values were calculated using t-test or Fisher’s exact test, appropriately. *, shows the statically significant difference from the control.
Figure 1Representative example of AS-OCT image and topographic map in one case analyzed in this study. The BCVA of each case was 20/28, 20/400, 20/50 and 20/100. AS-OCT = anterior segment optical coherence tomography, BCVA = best-corrected visual acuity, GCD2 = granular corneal dystrophy type 2, LCD1 = lattice corneal dystrophy type 1, LCD3A = lattice corneal dystrophy type IIIA, LCD4 = lattice corneal dystrophy type IV.
Each Fourier component.
| Anterior | Posterior | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Spherical | Regular | Asymmetry | Higher-order irregularity | Spherical | Regular | Asymmetry | Higher-order irregularity | ||
| Normal | Mean ± SD (D) | 49.0 ± 1.92 | 0.51 ± 0.32 | 0.32 ± 0.29 | 0.17 ± 0.10 | − 6.21 ± 0.25 | 0.17 ± 0.07 | 0.05 ± 0.03 | 0.02 ± 0.01 |
| Range (D) | 44.1, 53.9 | 0.10, 1.58 | 0.06, 1.92 | 0.06, 0.66 | − 6.89, − 5.76 | 0.01, 0.35 | 0.00, 0.12 | 0.01, 0.05 | |
| GCD2 | Mean + SD (D) | 49.4 ± 2.12 | 0.81 ± 0.51 | 0.52 ± 0.49 | 0.21 ± 0.09 | − 6.18 ± 0.30 | 0.17 ± 0.09 | 0.15 ± 0.15 | 0.06 ± 0.05 |
| Range (D) | 44.5, 53.9 | 0.14, 2.81 | 0.09, 3.48 | 0.11, 0.68 | − 6.77, − 5.50 | 0.04, 0.49 | 0.02, 0.78 | 0.02, 0.34 | |
| 0.27 | 0.0015* | 0.0023* | 0.037* | 0.67 | 0.90 | < 0.001* | < 0.001* | ||
| LCD (total) | Mean ± SD (D) | 48.0 ± 1.97 | 0.93 ± 0.84 | 0.91 ± 1.2 | 0.30 ± 0.21 | − 5.93 ± 0.35 | 0.32 ± 0.27 | 0.57 ± 0.59 | 0.31 ± 0.43 |
| Range (D) | 42.9, 51.7 | 0.06, 3.44 | 0.03, 5.17 | 0.11, 0.88 | − 6.79, − 5.33 | 0.05, 1.13 | 0.04, 2.41 | 0.02, 1.85 | |
| 0.056 | < 0.001* | < 0.001* | < 0.001* | < 0.001* | < 0.001* | < 0.001* | < 0.001* | ||
| LCD1 | Mean ± SD (D) | 47.9 ± 2.08 | 1.72 ± 1.04 | 1.65 ± 1.76 | 0.46 ± 0.28 | − 5.89 ± 0.31 | 0.24 ± 0.16 | 0.26 ± 0.47 | 0.06 ± 0.06 |
| Range (D) | 44.3, 50.8 | 0.47, 3.44 | 0.14, 5.17 | 0.18, 0.88 | − 6.23, − 5.36 | 0.07, 0.67 | 0.04, 1.65 | 0.02, 0.24 | |
| 0.56 | < 0.001* | < 0.001* | < 0.001* | 0.068 | 0.66 | 0.14 | 0.98 | ||
| LCD3 | Mean ± SD (D) | 47.8 ± 2.34 | 0.56 ± 0.36 | 0.44 ± 0.33 | 0.17 ± 0.05 | − 5.98 ± 0.39 | 0.23 ± 0.18 | 0.45 ± 0.42 | 0.23 ± 0.25 |
| Range (D) | 42.9, 50,5 | 0.06, 1.12 | 0.08, 1.24 | 0.12, 0.29 | − 6.49, -5.33 | 0.05, 0.63 | 0.07, 1.45 | 0.02, 0.90 | |
| 0.22 | 0.94 | 0.93 | 0.98 | 0.084 | 0.35 | 0.0012* | 0.0070* | ||
| LCD4 | Mean ± SD (D) | 48.3 ± 1.63 | 0.58 ± 0.41 | 0.67 ± 0.81 | 0.26 ± 0.11 | − 5.91 ± 0.37 | 0.47 ± 0.35 | 0.95 ± 0.62 | 0.58 ± 0.57 |
| Range (D) | 46.6, 51.7 | 0.17, 1.33 | 0.03, 3.24 | 0.11, 0.45 | − 6.79, − 5.45 | 0.06, 1.13 | 0.14, 2.41 | 0.08, 1.85 | |
| 0.54 | 0.90 | 0.27 | 0.050 | 0.011* | < 0.001* | < 0.001* | < 0.001* | ||
SD: Standard deviation, GCD2: Granular corneal dystrophy type 2, LCD: Lattice corneal dystrophy, LCD1: Lattice corneal dystrophy type 1, LCD3: Lattice corneal dystrophy type IIIA, LCD4: Lattice corneal dystrophy type IV.
p values were calculated using the linear mixed effect model. *, p value < 0.05.
Figure 2Fourier components for comparison between the phenotypes and controls. * indicates statistically significant difference. GCD = granular corneal dystrophy, LCD = lattice corneal dystrophy.
Association between BCVA and Fourier components.
| Anterior | Posterior | Total corneal | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Spherical | Regular | Asymmetry | Higher-order irregularity | Spherical | Regular | Asymmetry | Higher-order irregularity | Spherical | Regular | Asymmetry | Higher-order irregularity | ||
| GC | Coefficient | − 0.016 | 0.020 | 0.061 | − 0.11 | 0.039 | − 0.16 | 0.017 | − 0.085 | − 0.020 | 0.025 | 0.056 | − 0.21 |
| D2 | 0.20 | 0.67 | 0.40 | 0.72 | 0.66 | 0.58 | 0.90 | 0.84 | 0.17 | 0.63 | 0.47 | 0.41 | |
| LCD | Coefficient | − 0.054 | 0.28 | 0.27 | 1.55 | 0.19 | 0.40 | − 0.026 | 0.39 | − 0.050 | 0.37 | 0.22 | 0.57 |
| (total) | 0.25 | 0.012* | < 0.001* | < 0.001* | 0.39 | 0.13 | 0.87 | 0.029* | 0.32 | < 0.001* | < 0.001* | 0.0011* | |
| LCD1 | Coefficient | − 0.060 | 0.33 | 0.31 | 1.50 | 0.44 | − 1.42 | − 0.30 | − 3.28 | − 0.06 | 0.37 | 0.31 | 1.54 |
| 0.50 | 0.046* | < 0.001* | 0.064 | 0.60 | 0.33 | 0.52 | 0.35 | 0.52 | 0.02* | < 0.001* | 0.061 | ||
| LCD3 | Coefficient | − 0.042 | 0.35 | 0.47 | 3.30 | − 0.030 | − 2.32 | 0.46 | 0.70 | − 0.05 | 0.42 | 0.61 | 0.78 |
| 0.69 | 0.30 | 0.047* | 0.036* | 0.95 | 0.0048* | 0.24 | 0.12 | 0.66 | 0.26 | 0.0020* | 0.053 | ||
| LCD4 | Coefficient | − 0.10 | 0.15 | 0.18 | 1.59 | 0.23 | 0.67 | 0.11 | 0.43 | − 0.07 | 0.56 | 0.12 | 0.48 |
| 0.40 | 0.65 | 0.18 | 0.12 | 0.49 | 0.010* | 0.64 | 0.023* | 0.53 | 0.11 | 0.32 | 0.016* | ||
BCVA: Best-corrected visual acuity, GCD2: Granular corneal dystrophy type 2, LCD (total): Lattice corneal dystrophy (Includes all subtypes), LCD1: Lattice corneal dystrophy type 1, LCD3: Lattice corneal dystrophy type III A, LCD4: Lattice corneal dystrophy type IV.
Coefficients and p values were calculated using the linear mixed effect model. *, p value < 0.05.
Figure 3Fourier components for comparison between the subtypes and controls. * indicates statistically significant difference. GCD2 = granular corneal dystrophy type 2, LCD1 = lattice corneal dystrophy type 1, LCD3A = lattice corneal dystrophy type IIIA, LCD4 = lattice corneal dystrophy type IV.
Association between central corneal thickness and Fourier components.
| Anterior | Posterior | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Spherical | Regular | Asymmetry | Higher-order irregularity | Spherical | Regular | Asymmetry | Higher-order irregularity | ||
| GCD2 | Coefficient | 3.45 | − 1.16 | 0.90 | 27.3 | 28.8 | − 53.9 | − 9.53 | − 35.3 |
| 0.12 | 0.78 | 0.87 | 0.23 | 0.034* | 0.068 | 0.34 | 0.27 | ||
| LCD (total) | Coefficient | 6.44 | 0.25 | 5.50 | 22.3 | − 35.4 | 88.4 | 43.9 | 103 |
| 0.29 | 0.99 | 0.58 | 0.73 | 0.23 | 0.014* | 0.03* | < 0.001* | ||
| LCD1 | Coefficient | − 4.53 | 5.39 | 8.54 | 28.8 | 12.2 | − 15.6 | 11.7 | − 123 |
| 0.35 | 0.58 | 0.25 | 0.52 | 0.78 | 0.85 | 0.65 | 0.54 | ||
| LCD3 | Coefficient | − 4.4 | − 24.6 | 0.85 | 110 | 130 | − 51.1 | 21.5 | 93.7 |
| 0.65 | 0.46 | 0.98 | 0.56 | 0.020* | 0.48 | 0.42 | 0.032* | ||
| LCD4 | Coefficient | 40.3 | 37.3 | 9.56 | 68.5 | − 72.1 | 109 | 85.6 | 106 |
| 0.012* | 0.60 | 0.74 | 0.78 | 0.26 | 0.11 | 0.14 | 0.0037* | ||
GCD2: granular corneal dystrophy type 2, LCD (total): Lattice corneal dystrophy (Includes all subtypes), LCD1: Lattice corneal dystrophy type 1, LCD3: Lattice corneal dystrophy type IIIA, LCD4: Lattice corneal dystrophy type IV. Coefficients and p values were calculated using the linear mixed effect model. *, p value < 0.05.