Evaluation of the Effect of Storage Time on ROTEM S® Parameters in Healthy and Ill Dogs.

Nicole Weingand1, Johanna Vuille-Dit-Bille2, Rahel Jud Schefer1, Annette P N Kutter3, Martina Stirn3, Katja-Nicole Adamik2, Nadja E Sigrist1.   

Abstract

Viscoelastic testing as a bedside test to assess global haemostasis has gained popularity in the past decade, with rotational thromboelastometry (ROTEM) and thromboelastography (TEG) being the two commonly used devices. TEG studies suggest analysis 30 min after blood sampling. However, the reproducibility of results over time for ROTEM analysis using lyophilized samples in dogs has not been established. In this study, we investigated the influence of time on viscoelastic testing, using 33 healthy staff-/client-owned dogs for blood sampling and repeated measurements of ROTEM tracings at three different time points after blood collection. Additionally, a group of 21 hospitalized patients with suspected coagulation disorders were included to investigate whether stability over time was comparable between healthy and ill dogs. We demonstrated a significant difference of ROTEM tracings over time, with a tendency towards hypocoagulability over time. These changes do have a clinical relevance as they exceed reference intervals and could therefore lead to erroneous conclusions about a patient's coagulation status. Therefore, time-specific reference intervals are proposed and presented in this publication.

Entities:  

Keywords:  Ex-TEM; Fib-TEM; In-TEM; canine; reference interval; thromboelastometry

Year:  2022        PMID: 35953985      PMCID: PMC9367567          DOI: 10.3390/ani12151996

Source DB:  PubMed          Journal:  Animals (Basel)        ISSN: 2076-2615            Impact factor:   3.231


1. Introduction

Coagulation disturbances may cause life-threatening illness and rapid diagnosis of the underlying pathology of an acute coagulation disorder is mandatory. The use of viscoelastic measurements for detecting coagulation disorders in veterinary medicine gained popularity within the past decade [1,2,3,4]. Viscoelastic coagulation analysis allows for evaluation of haemostasis in whole blood from initiation of a fibrin clot to its maximum strength and the dissolution of the clot [5]. The two commonly used viscoelastic tests are thromboelastography (TEG) and rotational thromboelastometry (ROTEM). Rotational thromboelastometry analysis is performed with a fixed cup and an oscillating pin. While the pin rotates within the blood sample, its movement becomes restricted by clot formation and later liberated again by its lysis. Therefore, it provides information on clot formation kinetics and strength [6]. A real-time graph (temogram) is displayed on a screen and first conclusions can be made within 5–10 min [7]. Because of the quick availability of first results [8,9,10,11,12,13], the use of ROTEM in emergency settings is of great interest. However, fast results require immediate analysis after blood sampling. While the manufacturer recommends storage at 37 °C and immediate analysis in people, the Partnership of Rotational ViscoElastic Test Standardization (PROVETS) guidelines recommend a storage time of 30 min at room temperature [14]. Studies in people analysing the influence of storage time on coagulation parameter results show stable results for ROTEM parameters analysed between 0–120 min after blood collection of healthy volunteers [15,16]. However, a study investigating coagulability of coagulopathic trauma patients found a significant change in ROTEM tracings 0–60 min after blood sampling [17]. In veterinary science, studies about storage time and sample technique exist only for TEG [18,19] and the conclusions from these studies have been extrapolated to ROTEM analysis [20]. The optimal storage time of blood prior to ROTEM analysis has not been determined. A single study investigating weak and strong tissue factor activation reports that results measured 0 and 30 min after withdrawal are not different if a strong clotting activator is used. A weak activator led to hypercoagulability within the first 30 min of storage time [21]. According to the manufacturer, ROTEM S tests contain activators that lead to moderate activation of coagulation. Based on PROVETS guidelines, reference intervals for ROTEM parameters have been determined approximately 30 min after blood sampling [22,23] and it is currently unknown if earlier (for example in an emergency patient) or later (in research settings) analysis has an influence on results. Specifically, patients with acute bleeding disorders would benefit from immediate analysis and therefore faster availability of results. The aim of this study was to determine whether the time of ROTEM analysis after blood sampling has an influence on results. The null hypothesis was that samples analysed 10 or 70 min after blood sampling were not significantly different from samples analysed 30 min after blood sampling. A second aim was to determine if coagulation status (hypo-, normo- or hypercoagulable) and sampling technique (jugular venipuncture using a syringe vs. free-flowing blood collection from a saphenous vein) influences consistency of results over time. In case of significant differences at the measurement points, an additional goal was to determine reference intervals for measurements after 10 and 70 min, respectively.

2. Materials and Methods

The study was conducted at the Small Animal Clinic of the Vetsuisse Faculty, University of Zurich between March and May 2021 and was completed together with another study investigating pre-analytical factors that could influence test results [24]. It was approved by the ethics committee on animal research of the Canton of Zurich (ZH 057/19) and owner consent was obtained. Sample size was chosen based on previous studies [16,21]. Student-, staff-, and client-owned dogs were recruited for blood sampling. Demographic data (age, breed, sex, and body weight), current medication, and medical history were recorded of all dogs. Chronic illness or current medication were not an exclusion criteria. Dogs were excluded when they weighed < 2 kg, were younger than 10 months, or were too stressed for blood sampling.

2.1. Blood Sampling

Blood sampling was performed on one or two phlebotomy sites (vena jugularis and/or vena saphena lateralis) depending on the weight (two phlebotomies were only performed if bodyweight > 10 kg), the character of the dog, and the owner’s consent. For dogs with one phlebotomy site, either the jugular vein or the lateral saphenous vein was prepared aseptically and approximately 4 mL blood was collected. For dogs with two phlebotomy sites, both the jugular vein and the lateral saphenous vein were prepared aseptically, and blood was drawn first at the jugular vein (3 mL) followed immediately by blood collection at the lateral saphenous vein (2.6 mL). Standardized venipuncture was performed by two operators (JV and NW) to reduce the influence of preanalytical errors [14,20,25]. For jugular vein sampling, a 22 G needle was connected to a 5 mL syringe and blood was drawn using minimal vessel occlusion and mild aspiration with a vacuum of 1 ml inside the syringe. After needle removal, the blood was filled into two or three 1.3 ml 3.8% sodium citrate tubes (SAB500 Sarstedt blood collection tube, 1.3 mL, 3.2% sodium citrate) with a strict 1:9 ratio. Blood sampling at the lateral saphenous vein was performed with a 22G needle and blood was collected free-flowing in two or three 1.3 mL 3.8% sodium citrate tubes with a strict 1:9 ratio. Each tube was inverted carefully several times and was then placed on the analysers’ warming plate.

2.2. ROTEM Analysis

Viscoelastic testing was performed by three trained operators on two ROTEM devices with 4 channels each (TEM innovations GmbH, Munich, Germany) with one operator handling one device at a time. ROTEM analysis was performed using single test vials for extrinsic rotational thromboelastometry—Ex-TEM S (tissue factor-activated temogram), intrinsic rotational thromboelastometry—In-TEM S (ellagic acid-activated temogram) and fibrinogen rotational thromboelastometry—Fib-TEM S (tissue factor-activated temogram with platelet inhibition) (all TEM innovations GmbH, Munich, Germany). From each tube, three serial measurements of the same test were performed (e.g., of the three tubes, one was used for Ex-TEM S, one for In-TEM S, and one for Fib-TEM S analysis). Each tube was rested at 37 °C for at least 3–5 min prior to the first analysis. The first ROTEM measurement was performed 10 +/− 2 min, the second measurement 30 +/− 2 min and the third measurement 70–80 min after blood sampling. The channels were chosen randomly by the tester; however, the first and the third measurement were performed at the same channel to exclude channel-dependent variability. If there were two sampling sites, only two tests could be performed due to channel availability. For each sample, an Ex-TEM S was performed. The second test was chosen randomly, with the aim of having a similar number of In-TEM S and Fib-TEM S results. Samples were analysed according to the manufacturer instructions. Briefly, the cups and pins were placed correctly, and the reagents were allowed to reach room temperature, by placing them in the designated spaces on the device approximately 10 min prior to analysis. Using an automated pipetting program provided by the device, 300 µL of 37.0 °C warm, citrated whole blood was incubated for 5 s with the appropriate single portion reagent (Ex-TEM S, Fib-TEM S, In-TEM S) and afterwards pipetted into the ROTEM cuvette (Cup and Pin Pro, TEM Innovations GmbH, Munich, Germany). The cuvette was then connected to the pin and the measurement was started. The running time of all samples was 60 min with the exemption of Fib-TEM S tracings, which were stopped after 30 min if an additional channel was needed. Every temogram was visually evaluated for artefacts by two of the investigators (N.E.S., N.W.). The following parameters were further analysed: clotting time (CT—time from start of the measurement until the initiation of a clot with an amplitude of 2 mm); clot formation time (CFT—time between 2 mm and the time until the clot reached an amplitude of 20 mm); α-angle (α—angle between baseline and clotting curve; going through the CT point); maximum clot firmness (MCF—maximum amplitude reached in the measurement); maximum clot elasticity (MCE—a parameter for the clots’ elasticity calculated as E = 100 × MCF/(100−A)); maximum lysis (ML—difference between MCF and the lowest amplitude after MCF is the maximum lysis detected during the runtime); amplitude at 10 min (A10—the amplitude reached by the clot 10 min after test start); and G (Shear Elastic Modulus Strength, which is calculated as 5000 × MCF/(100−MCF)).

2.3. Additional Blood Analysis

A venous blood gas analysis was performed by placing 0.3 mL of the left-over blood into a heparinized syringe (BD A-line blood gas syringe, Becton Dickinson and Company, Plymouth UK) immediately followed by analysis on a point-of-care blood gas analyser (RAPID Point 500, Siemens Healthcare, Zurich, Switzerland). Micro-haematocrit, total solids and a blood smear for manual thrombocyte counting was performed from left-over blood of one of the citrate tubes of each blood sampling localization. Serum colour was noted. Blood smears were stained using a Wright-Giemsa stain (Diff-Quick, Medion Diagnostics, Düdingen, Switzerland) and thrombocyte number was estimated by counting the average number of thrombocytes seen in 100× oil immersion (Olympus CX 43, Olympus Europa SE & Co. KG, 20097 Hamburg, Germany). A total of 10 monolayer high-power fields were viewed, and the average platelet count was multiplied by 15.000. All blood smears were interpreted by the same operator (N.W.).

2.4. Clinical Cases

Additionally, leftover citrate blood from patients undergoing ROTEM analysis for clinical purposes were included if the first ROTEM analysis was performed 10 +/− 2 min after blood sampling. Since there was generally only one citrate tube available, only Ex-TEM at the 30 and/or 70 min timepoint was repeated.

2.5. Coagulation Status

Based on previously established reference intervals for G [22], a calculated parameter considered to be a measure of complete clot strength, tracings were categorized as hypocoagulable, hypercoagulable or normocoagulable [26]. G at 30 min was considered as reference coagulation status. Study dogs were deemed healthy based on a physical exam, history, haematocrit, electrolytes, blood gas, glucose, and lactate analysis (RAPID Point 500, Siemens Healthcare, Zurich, Switzerland) were used for determination of reference intervals at the 10 and 70 min timepoints.

2.6. Data Analysis and Statistics

Data from the ROTEM database was copied into an excel sheet. The database was manually checked for errors by two authors (NW, NS). Statistical analysis was performed using IBM SPSS Statistics version 27 (IBM Corporation, Armonk, New York, NY, USA). All parameters were tested for normality in their distribution using the Shapiro–Wilk test. Afterwards, data were tested for outliers using Tukey analysis. No dataset was excluded from further analysis. Because most of the measured values were not normally distributed, for all further statistical tests non-parametrical tests were chosen and results are displayed as median and range (min–max). Friedman and Wilcoxon rank tests were performed to analyse changes over time (repeated measurements) and post hoc correction was performed using Bonferroni correction. Multiple logistic regression for change in coagulation status between T10–T30 and T30–T70 was performed with the covariant factors platelet number, haematocrit, haemolysis (yes/no), and sampling site (jugular/peripheral). A 95% confidence interval was set and a p-value < 0.05 was set as statistically significant. Reference intervals at T 10 and T 70 were performed from 36 clinically healthy dogs without current medication using a statistical program (MedCalc® Statistical Software version 20.027 (MedCalc Software Ltd., Ostend, Belgium; https://www.medcalc.org; accessed on 16 March 2022) Reference intervals were reported as 2.5th–97th percentile with 90% confidence interval were determined by a nonparametric method (non-parametric data) or following CLSI guidelines for percentiles and their confidence interval (normally distributed data).

3. Results

A total of 55 dogs were enrolled. One dog was excluded as the dog’s blood clotted inside the tubes. The 54 included dogs were aged between 9 and 200 months (median, 82 months) and had a body weight ranging from 2.3 to 59 kg (median, 21.6 kg). In total, 11 (20.4%) were intact males, 18 (33.3%) castrated males, 7 (13.0%) intact females, and 18 (33.3%) castrated females. Of these, 16 were mixed-breed dogs and 38 were pedigree dogs; 5 of them were Labrador Retrievers, 3 Border Collies, and 3 French Bulldogs; there were 2 from each of the following breeds—German Shepherd, Pit Bull Terrier, German Wirehaired Pointer, Golden Retriever, Chihuahua, Australian Shepherd, Akita Inu; and there were 1 from each of the following breeds—Rhodesian Ridgeback, Poodle, Bolonka Zwetna, Magyar Vizsla, Malinois, Greater Swiss Mountain Dog, Schappendoes, Whippet, Papillon, Labradoodle, Maltese, Berger Blanc Suisse, and Dachshund. The haematocrit ranged from 25 to 52% (median, 40%, reference interval 36–54%) and 9 dogs showed haematocrits below the reference interval. Total solids ranged from 41 to 78 g/L (median, 59 g/L, reference interval 53–76 g/L) and thrombocyte count ranged from 0/µL to 587,000/µL (median, 200,000/µL, reference interval 150–399,000/µL). Ionized calcium measurements were available in 20 dogs and ranged from 1.18 to 1.36 mmol/L (median, 1.28 mmol/L; reference interval 1.25–1.4 mmol/L). A total of 21 of 54 dogs (39%) were client-owned dogs, which presented with different suspected or proven bleeding disorders including haemoabdomen (n = 3), immune-mediated thrombocytopenia (n = 3), and Angiostrongylus vasorum infection (n = 2), among other diagnoses.

3.1. ROTEM S Parameter Changes over Time

A total of 71 blood samples, 50 from 33 staff-/student-owned dogs and 21 from patients, were analysed. Ex-TEM S and In-TEM S analysis was performed at all investigated timepoints (T10, T30, T70) in 68/71 and 35/71 samples, respectively, while Fib-TEM S analysis was performed in 28/71 blood samples. Table 1 summarizes median values of the investigated parameters at each timepoint. Ex-TEM S analysis showed a significant change over time in all investigated parameters (p < 0.01), except from CT (p > 0.05) (Figure 1). With the exemption of CT and ML, all In-TEM S parameters evaluated showed significant changes between T10 and T70 and T30 and T70, but not T10 and T30 (p < 0.05). For Fib-TEM tracings significant changes were only observed between T10–T70 (p < 0.05) (Table 1). Changes in G-value over time are shown in Figure 1.
Table 1

Ex-TEM, In-TEM, and Fib-TEM parameters over time.

Parameter Time after Blood SamplingFriedman
T10 T30 T70 overall
Ex-TEMnreference rangemedianrangemedianrangemedianrange p
CT6823–873519–36003620–6563420–5440.260
CFT6885–35721948–360023948–360025866–3600 <0.001
alpha angle6842–77531–84521–85491–85 <0.001
A106821–55341–66321–68314–62 <0.001
MCF6832–65451–72434–73417–68 <0.001
ML680–1250–1240–3130–11 <0.001
MCE6845–142821–256754–272697–210 <0.001
G682253–5928407751–12,8013730221–13,6233445357–10,485 <0.001
In-TEMnreference rangemedianrangemedianrangemedianrange p
CT35133–210181115–239185136–230184133–2400.188
CFT3559–2019439–23610733–43713338–277 <0.001
alpha angle3558–787352–827037–836744–82 0.001
A103535–614633–694624–734231–70 <0.001
MCF3552–716050–755842–785646–76 <0.001
ML350–300–100–200–10.558
MCE35108–242148100–29613872–35712785–309 <0.001
G355417–12,11974145000–14,79569023621–17,87163644259–15,450 0.001
Fib-TEMnreference rangemedianrangemedianrangemedianrange p
CT2821–1123626–27273526–36003824–36000.742
A10282–952–2151–2441–20 0.005
MCF282–952–2261–2341–21 0.035
ML281–99140–45140–5290–480.695
MCE282–1063–2861–3051–26 0.039
G28113–509272125–138229151–152122451–13190.286

CT—clotting time;CFT—clot formation time; ML—maximum lysis; MCF—maximum clot formation; MCE—maximum clot elasticity; A10—amplitude at 10 min; G—measure of clot strength; Ex-TEM—tissue factor activated temogram; In-TEM— allegic acid-activated temogram; Fib-TEM— tissue factor-activated temogram with platelet inhibition; T10—10 min after blood sampling; T30—30 min after blood sampling; T70—70–80 min after blood sampling. Significant p-values are presented in bold.

Figure 1

Box-plot graphs of G-value analysed 10, 30, and 70 min after blood sampling (a) Ex-TEM S (b) In-TEM S, (c) Fib-TEM S.

3.2. Parameter Changes over Time Based on Coagulation Status

Based on G at the timepoint T30, 51/68 (75%) Ex-TEM S tracings, 27/35 (77%) In-TEM S tracings and 23/28 (82%) Fib-TEM S tracings were classified as normocoagulable; 11/68 (16%) Ex-TEM S, 6/35 (17%) In-TEM S and 2/28 (7%) Fib-TEM S as hypocoagulable; while 6/68 (9%) Ex-TEM S, 2/35 (6%) In-TEM S and 3/28 (11%) Fib-TEM S tracings were hypercoagulable. Parameter changes over time are summarized in Table 2, Table 3 and Table 4.
Table 2

Normocoagulable tracings of Ex-TEM, In-TEM, and Fib-TEM over time.

Parameter. Time after Blood SamplingFried manWilcoxon
T10 T30 T70 overallT10-30T30-70T10-70
Ex-TEMnreference rangemedianrangemedianrangemedianrange p p p p
CT5123–873519–1063520–1243420–1600.0930.7790.1030.153
CFT5185–35721397–422225111–42625466–1215 <0.001 0.004 0.004 <0.001
alpha angle5142–775341–835341–824927–85 <0.001 0.134 <0.001 <0.001
A105121–553524–543323–463115–62 <0.001 <0.001 0.019 <0.001
MCF5132–654532–714432–544123–68 <0.001 <0.001 0.028 <0.001
ML510–1250–1250–1530–11 <0.001 0.033 <0.001 <0.001
MCE5145–1428248–2497848–1157030–210 <0.001 0.001 0.024 <0.001
G512253–592841082392–12,46438962396–576835191479–10,485 <0.001 <0.001 0.024 <0.001
In-TEMnreference rangemedianrangemedianrangemedianrange p p p p
CT27133–210184115–239185136–217186133–2400.4200.9570.3810.540
CFT2759–2018747–14510452–15412360–277 <0.001 0.101 <0.001 <0.001
alpha angle2758–787363–807062–796744–78 <0.001 0.209 0.001 <0.001
A102735–614841–634640–604234–60 <0.001 0.241 <0.001 <0.001
MCF2752–716054–715953–705647–72 <0.001 0.173 <0.001 <0.001
ML270–300–100–200–10.5580.4800.7390.257
MCE27108–242150117–240145112–23912788–257 <0.001 0.273 <0.001 <0.001
G275417–12,11975005868–11,98172755620–11,93263644377–12,831 <0.001 0.368 <0.001 <0.001
Fib-TEMnreference rangemedianrangemedianrangemedianrange p p p p
CT2321–1123626–1593626–8413824–2410.7860.7930.5920.637
A10232–953–1052–942–19 0.018 0.2100.146 0.045
MCF232–953–1053–943–19 0.043 0.3300.127 0.049
ML231–99141–43154–52100–480.3930.4200.1440.648
MCE232–1053–1163–1053–24 0.046 0.3070.245 0.041
G23113–509266143–572266129–494221145–12020.3370.4650.1530.057

CT—clotting time; CFT—clot formation time; ML—maximum lysis; MCF—maximum clot formation; MCE—maximum clot elasticity; A10—amplitude at 10 min; G—measure of clot strength; Ex-TEM—tissue factor activated temogram; In-TEM— allegic acid-activated temogram; Fib-TEM— tissue factor-activated temogram with platelet inhibition; T10—10 min after blood sampling; T30—30 min after blood sampling; T70—70–80 min after blood sampling. Significant p-values are presented in bold.

Table 3

Hypocoagulable Ex-TEM, In-TEM, and Fib-TEM tracings over time.

Parameter Time after Blood SamplingFriedmanWilcoxon
T10 T30 T70 overallT10-30T30-70T10-70
Ex-TEMnreference rangemedianrangemedianrangemedianrange p p p p
CT1123–877826–360011824–6566931–5440.8500.5050.6460.790
A101121–55181–38171–21164–290.061 0.013 0.9180.085
CFT1185–357807218–3600891567–36001171281–36000.132 0.022 0.5940.059
MCF1132–65271–47254–29237–410.303 0.036 0.4110.213
alpha angle1142–77371–67291–77271–760.0820.2620.3300.059
ML110–1210–1210–1020–9 0.044 0.0840.2210.056
MCE1145–142361–89334–42307–680.319 0.032 0.6550.155
G112253–5928180451–44591641221–20911493357–30570.336 0.026 0.5940.182
In-TEMnreference rangemedianrangemedianrangemedianrange p p p p
CT6133–210179132–229212174–230194177–2110.3110.1160.4630.249
A10635–613833–413624–373531–410.5540.1380.8330.345
CFT659–201165141–236190169–437207130–2530.4380.2250.6000.463
MCF652–715350–565242–525246–570.337 0.042 0.6740.527
alpha angle658–786252–655737–615850–660.5130.1410.4630.599
ML60–3000000 1.0001.0001.000
MCE6108–242111100–12610872–10810885–1330.337 0.043 0.5280.528
G65417–12,11955275000–632453793621–541754214259–66460.337 0.043 0.6000.528
Fib-TEMnreference rangemedianrangemedianrangemedianrange p p p p
CT221–1121424121–272736003600–360033143027–36000.1560.1800.3170.180
A1022–922–211–111–10.1350.1571.0000.157
MCF22–932–311–121–20.1560.1800.3170.157
ML21–993932–450030–60.1560.1800.3170.180
MCE22–1033–311–121–20.1560.1570.3170.180
G2113–509135125–1455151–517851–1060.1560.1800.3170.180

CT—clotting tim; CFT—clot formation time; ML—maximum lysis; MCF—maximum clot formation; MCE—maximum clot elasticity; A10—amplitude at 10 min; G—measure of clot strength; Ex-TEM—tissue factor activated temogram; In-TEM— allegic acid-activated temogram; Fib-TEM— tissue factor-activated temogram with platelet inhibition; T10—10 min after blood sampling; T30—30 min after blood sampling; T70—70–80 min after blood sampling. Significant p-values are presented in bold.

Table 4

Hypercoagulable Ex-TEM, In-TEM, and Fib-TEM tracings over time.

Parameter Time after Blood SamplingFriedmanWilcoxon
T10 T30 T70 overallT10-30T30-70T10-70
Ex-TEMnreference rangemedianrangemedianrangemedianrange p p p p
CT623–872825–962825–352820–290.9530.4630.6841.000
A10621–555241–665345–684844–490.1540.3430.0580.138
CFT685–35711248–1389748–146119106–155 0.032 0.686 0.028 0.093
MCF632–656050–726256–735855–600.1080.2160.0580.138
alpha angle642–777466–847762–857161–840.1540.5270.1150.138
ML50–1222–722–620–60.0970.3170.1800.102
MCE645–142148100–256160125–272137120–1470.0840.225 0.046 0.116
G62253–592873904985–12,80179956231–13,62368376022–73680.0840.225 0.046 0.116

CT—clotting time; CFT—clot formation time; ML—maximum lysis; MCF—maximum clot formation; MCE—maximum clot elasticity; A10—amplitude at 10 min; G—measure of clot strength; Ex-TEM—tissue factor activated temogram; T10—10 min after blood sampling; T30—30 min after blood sampling; T70—70–80 min after blood sampling. Significant p-values are presented in bold.

For normocoagulable samples, the results were very similar to those of the whole population (Table 2). All investigated Ex-TEM S variables significantly (p < 0.05) differed between time points, except from CT at all timepoints (p > 0.05), and α-angle between T10 and T30 (p > 0.05). The results for normocoagulable In-TEM S parameters matched the whole population group, showing significant changes over time only between T10 and T70 (p < 0.001) and T30 and T70 (p < 0.001) There was no significant difference for CT and ML (p > 0.05) between any of the timepoints (Table 2). In normocoagulable Fib-TEM S tracings, significant changes over time were observed between T10 and T70 for A10, MCF, and MCE (all p < 0.05) (Table 2). In hypocoagulable Ex-TEM S samples (Table 3), significant changes between the timepoints T10 and T30 were noted for A10, CFT, MCF, MCE and G (all p < 0.05), while in hypocoagulable In-TEM S tracings, MCF, MCE, and G changed significantly between T10 and T30 (all p < 0.05). No significant changes could be observed between T30 and T70. For hypercoagulable Ex-TEM S samples significant changes between T30 and T70 were found for CFT, MCE, and G (all p < 0.05) (Table 4). Hypercoagulability was only recognized in 2 In-TEM S and 3 Fib-TEM S samples and changes over time were not analysed.

3.3. Change of Coagulation Status

With Ex-TEM S analysis, 7/70 (10%) of hypercoagulable samples at T10 turned to normocoagulability at T30, and 5/70 (7.1%) of normocoagulable samples at T10 were interpreted as hypocoagulable at T30 (Table 5).
Table 5

Coagulation status over time.

TESTCoagulation StatusT10T30T70 p
n/N (%)n/N (%)n/N (%)
Ex-temnormocoagulable52/70 (74%)53/70 (75%)50/68 (73%) <0.001
hypocoagulable6/70 (9%)11/70 (16%)12/68 (18%)0.336
hypercoagulable12/70 (17%)6/70 (9%)6/68 (9%)0.084
In-temnormocoagulable32/35 (91%)27/35 (77%)28/35 (80%) <0.001
hypocoagulable2/35 (6%)6/35 (17%)5/35 (14%) 0.043
hypercoagulable1/35 (3%)2/35 (6%)2/35 (6%)0.135
Fib-temnormocoagulable25/28 (89%)23/28 (82%)22/28 (79%)0.337
hypocoagulable0/28 (0%)2/28 (7%)2/28 (7%)0.156
hypercoagulable3/28 (11%)3/28 (11%)4/28 (14%)0.097
Ex-TEM—tissue factor activated temogram; In-TEM—allegic acid-activated temogram; Fib-TEM— tissue factor-activated temogram with platelet inhibition; T10—10 minutes after blood sampling; T10—10 min after blood sampling; T30—30 min after blood sampling; T70—70–80 min after blood sampling. Significant p-values are presented in bold. Between T30 and T70, 3/68 (4.4%) of samples changed from hypo- to normocoagulability and another 3/68 (4.4%) from normo- to hypocoagulability, 1/68 (1.5%) turned from hypercoagulable to normocoagulable and 1/68 (1.5%) changed from hyper- to hypocoagulable (Table 5) in comparison with T 30 tracings. In In-TEM S tracings, 4/35 (11.4%) of normocoagulable objects at T10 turned hypocoagulable at T 30 and 1/35 (2.9%) became hypercoagulable. In the time between T30 and T70 1/35 (2.9%) sample changed from hypocoagulability to normocoagulability (Table 5). In Fib-TEM S tracings, 2/28 (7.1%) normocoagulable tracings at T10 changed to hypocoagulable tracings at T30. One of 28 (3.6%) samples changed from hyper- to normocoagulability and another 1/28 (3.6%) turned from normo- to hypercoagulability. At T70 2/28 (7.1%) samples turned from normo- to hypercoagulability, whereas 1/28 (3.6%) turned from hyper- to normocoagulability (Table 5) when compared to T30 tracings.

3.4. Effect of Sampling Site, Degree of Haemolysis, Haematocrit, and Platelet Count

Binary logistic regression showed that haematocrit was a significant covariant for a change in Ex-TEM S coagulation status between T10–T30 but not T30–T70. The probability of a coagulation status change in Ex-TEM S decreased by 20% with each percent increase in haematocrit (n = 50, p = 0.035, R2 = 0.386, Cohens f2 = 0.63, odds ratio 0.802, 95% confidence interval 0.652–0.986). None of the analysed covariants (haematocrit, platelet number, haemolysis, sampling site) were significantly associated with a change in In-TEM S or Fib-TEM S coagulation status.

3.5. Reference Intervals for Analysis 10, 30, and 70 min after Blood Sampling

Reference intervals for Ex-TEM S, In-TEM S, and Fib-TEM S parameters at 10 and 70 min after blood sampling are summarized in Table 6. Most reference intervals significantly differed over time (Table 6).
Table 6

Reference intervals for selected parameters of Ex-TEM S, In-TEM S, and Fib-TEM S 10, 30, and 70 min after blood sampling.

TestParameterTime after SamplingnReference Interval(RI by Jud)Lower and Upper 90% CIFriedmann Test
Ex-temCT (s)10 min3626–88NA0.384
30 min3623–113(23–87)NA
70 min3625–140NA
CFT (s)10 min3696–32778–125 and 299–355<0.00001
30 min3676–408(85–357)36–117 and 367–449
70 min33128–482NA
A (°)10 min3639–7335–43 and 68–77<0.00001
30 min3637–72(42–77)32–41 and 68–77
70 min3628–7023–33 and 65–75
A10 (mm)10 min3625–4922–28 and 44–50<0.00001
30 min3621–46(21–55)17–24 and 43–49
70 min3617–4614–21 and 42–49
MCF (mm)10 min3636–5833–38 and 54–59<0.0001
30 min3632–56(32–65)29–35 and 53–60
70 min3628–5624–31 and 53–60
MCE10 min3649–12740–58 and 118–137<0.0001
30 min3650–141(45–142)NA
70 min3631–12020–42 and 109–131
G10 min362742–6965NA<0.0001
30 min362509–7023(2253–5928)NA
70 min361535–5996989–2080 and 5450–6541
ML (%)10 min361–9 <0.0001
30 min350–15(0–12)
70 min360–80 and 7–9
In-temCT (s)10 min25126–234110–142 and 218–2500.20061
30 min25140–233(133–210)126–154 and 220–247
70 min25136–240120–151 and 225–256
CFT (s)10 min2553–234NA<0.0001
30 min2427–207(59–201)0–54 and 180–234
70 min2536–2463–68 and 224–289
A (°)10 min2555–8251–60 and 78–860.015
30 min2539–79(58–78)NA
70 min2549–80
A10 (mm)10 min2531–6129–36 and 57–66<0.0001
30 min2527–63(35–61)22–33 and 58–68
70 min2549–8045–54 and 76–85
MCF (mm)10 min2550–85NA0.001
30 min2545–72(52–71)41–49 and 68–75
70 min2446–68NA
MCE10 min24100–230NA0.003
30 min2576–237(108–242)NA
70 min2486–207NA
G10 min245020–11,508NA0.006
30 min253781–11,834(5417–12,119)NA
70 min244289–10,371NA
ML (%)10 min250–1NA0.696
30 min250–1(0–3)NA
70 min250–1NA
Fib-temCT (s)10 min2128–158NA0.734
30 min1927–92(21–112)NA
70 min
A10 (mm)10 min220–100–2 and 8–110.013
30 min220–10(2–9)0–2 and 8–11
70 min220–130–4 and 4–17
MCF (mm)10 min203–10NA0.074
30 min202–9(2–9)0–3 and 8–11
70 min203–19NA
MCE10 min203–11NA0.067
30 min203–12(2–10)NA
70 min203–24NA
G10 min20143–572NA0.544
30 min2062–523(113–509)0–137 and 446–600
70 min19145–561NA

NA—not available; CT—clotting time; CFT—clot formation time; ML—maximum lysis; MCF—maximum clot formation; MCE—maximum clot elasticity; A10—amplitude at 10 min; G—measure of clot strength; Ex-TEM—tissue factor activated temogram; In-TEM—allegic acid-activated temogram; Fib-TEM— tissue factor-activated temogram with platelet inhibition.

4. Discussion

Repeated analysis of ROTEM S parameters measured in citrated canine whole blood showed significant changes over time. These changes were identified in all evaluated ROTEM S tests (Ex-TEM, In-TEM, Fib-TEM), with more affected parameters in Ex-TEM S tracings compared to In-TEM S or Fib-TEM S analysis. Additionally, the changes had a significant effect on the interpretation of coagulation status based on available reference intervals. These findings are in contrast with equivalent studies in people, where good stability over time was reported (CV < 6% in all assays) [27]. Although some significant changes were identified in Fib-TEM and In-TEM analysis when different devices were used in people, none of these changes had any therapeutic consequence because changes were within the reference range [16,27]. When classifying the coagulation status of a ROTEM tracing based on the G value, our results showed a clinically relevant change over time. Specifically, some tracings defined as hypocoagulable at T30 were interpreted as normocoagulable at T10 when using the institution’s reference interval evaluated 25–35 min after blood sampling. Therefore, new reference intervals for analyses after 10 min and 70 min were generated. These new reference intervals, despite being based on low numbers of patients, significantly differed between different time points. An earlier study in dogs investigating storage time and activator use in ROTEM analysis showed a trend towards hypercoagulability over time. However, these changes were minor as long as a strong activator was used [21]. According to the manufacturer, ROTEM S tests contain activators that lead to moderate activation of coagulation, indicating that, if at all, a trend towards hypercoagulability over time could be expected. Studies evaluating the influence of time on ROTEM analysis in people show contradictory results. In healthy people, ROTEM parameters were shown to be stable over 120 min [16]. A study evaluating blood from trauma patients showed a spontaneous improvement in clot firmness with time [17]. Since these changes were not identified in Fib-TEM tracings, this finding was suspected to be caused by a change in platelet function following trauma. Thromboelastography studies in healthy adults also showed a trend towards hypercoagulability over time [15,28]. In these TEG studies, results were more hypocoagulable immediately after recalcification; this finding was explained by delayed thrombin formation in recalcified samples [15,28], leading to the recommendation of 30 min storage time before analysis. These results from TEG and ROTEM stands in contrast with our results showing a trend for tracings becoming more hypocoagulable over time. The reasons for changes over time in ROTEM parameters and specifically the trend towards hypocoagulability over time has not been described so far and need further investigation. A possible explanation may be the complex method of platelet activation. During normal conditions, platelets flow in the blood stream without interacting with the endothelial surface or each other. However, platelets are very reactive to external stimuli and endothelial damage [29]. As soon as thrombocyte activation starts, the formation of a reversible clot is initiated. This clot relies on an irreversible activation of αIIbβ3 for stable clot formation [30,31]. Therefore, platelet activation and aggregation to each other induced by blood sampling could explain the hypercoagulable tendency found at T 10 while after 30 min, platelet activation has resolved. Of note, all previous studies have investigated liquid ROTEM reagents, which, in contrast to the lyophilized ROTEM S reagents in our study, require recalcification of the reagent prior to analysis. A difference in reference intervals between multi-test vials and single-test vials has been found in a previous study of [22]. The reason for this discrepancy is unclear; however, an insufficient activation of canine blood by tissue factor has been discussed [22]. Ex-TEM S was the most sensitive to changes over time. Tissue factor, the activator used in Ex-TEM S, and ellagic acid (In-TEM S) are considered strong activators [14,21]. Previous studies in dogs investigating lyophilized ROTEM reagents suspected that tissue factor concentration in Ex-TEM S and Fib-TEM S reagents may be insufficient for complete activation of coagulation in canine blood, leading to smaller MCF reference intervals compared to reference intervals determined with liquid Ex-TEM reagents [22]. The clot formation 10 min after blood sampling may then be improved due to platelet activation as described above, while measurement 30 min after blood sampling shows longer CT and CFT. Preanalytical factors that may influence results of viscoelastic testing include sampling technique [19], venipuncture quality [32], haemolysis [33], and haematocrit [34] with hypercoagulability in anaemic samples. Sampling site and technique did not have a significant influence on the change in coagulation status, neither did the thrombocyte number, despite some dogs having very low platelet numbers. An increase in haematocrit was associated with a major decrease in the probability of a change in coagulation status. This indicates that anaemic patients may be more susceptible to the effect of time on coagulation status. Further investigations are needed especially in anaemic patient groups of different severities to verify this effect. Furthermore, the influence of haemolysis on results could not be investigated, as data regarding serum colour was missing in most clinically ill patients. Haemolysis is associated with a reduced clot firmness und hypocoagulability in TEG analysis [33]. Normocoagulable samples showed the most prominent changes over time, while hypocoagulable samples were still affected, but less. This may be explained by the trend towards hypocoagulability over time, as no difference between mild and severe hypocoagulability was made. Due to the small sample size, this finding must be interpreted with caution. Furthermore, there is currently no standardized method to define normo-, hyper-, or hypocoagulability. Prolonged CT, reduced α, or reduced MCF can be indicative for hypocoagulability and a decreased time to clot formation, an increased α-angle or an increased MCF are indicative for hypercoagulability. We decided to use G values at T 30 for definition of normo-, hyper-, and hypocoagulability as G has been used in previous studies. G is a measure for the global clot strength and by representing an exponential transformation of MCF, it is more sensitive to haemostatic changes [26,35,36]. Another explanation for the change in ROTEM parameters and coagulation status over time may be the lack of duplicate measurements. The use of a high tissue factor concentration should lead to adequate activation of coagulation and results in a stable assay and should be less sensitive for pre-analytical influences [14]. Due to the serial measurement and limitation to 8 ROTEM channels, only a few samples were measured in duplicate. The coefficient of variation (CV) of these as well as additional samples have been evaluated in the concurrent study investigating the intra-assay and intra- and inter-operator variance [24]. Ex-TEM and Fib-TEM parameters showed only moderate repeatability while In-TEM parameters showed an excellent repeatability (CV < 10%). Clotting time and CFT showed the highest CV in all tests while MCF and G showed excellent repeatability in all tests, including Ex-TEM. While we cannot exclude an influence of this high variability on the results over time, our results suggest that there are significant changes and a trend towards hypocoagulable samples over time. Given the important change in coagulation status, time of analysis after blood sampling needs to be considered when interpreting ROTEM results in clinical patients. As long as the pathophysiology and cause of the change over time is not determined, it is not clear at which timepoint after blood sampling the “true” coagulation status (T10 vs. T30 vs. T70) is measured and reference intervals for all timepoints are required for appropriate interpretation of results. According to the results of our study, not only should institutional reference intervals be established, but the timing of analyses must also be standardized. The reference intervals presented in this study are only preliminary, as a larger patient population is required. The main limitation of the study is its small sample sizes of hypo- und hypercoagulable In-TEM and Fib-TEM tracings. Further studies to investigate the influence of time in dogs with abnormal coagulation status are of great interest. Another limitation is that for ill dogs, the sample handling was performed by different operators. While all operators were trained in ROTEM analysis, an influence by handler manipulation cannot be completely ruled out.

5. Conclusions

In conclusion, ROTEM S tracings of canine citrated whole blood show a significant and clinically relevant change over time, being most prominent in Ex-TEM S tracings. Our results indicate that some parameters and tracings may become hypocoagulable over time. Specific reference intervals for different timepoints are required to avoid any false interpretation of a patient’s coagulation status.
  35 in total

Review 1.  Rotational thromboelastometry-guided trauma resuscitation.

Authors:  Damian D Keene; Giles R Nordmann; Tom Woolley
Journal:  Curr Opin Crit Care       Date:  2013-12       Impact factor: 3.687

2.  Fast interpretation of thromboelastometry in non-cardiac surgery: reliability in patients with hypo-, normo-, and hypercoagulability.

Authors:  K Görlinger; D Dirkmann; C Solomon; A A Hanke
Journal:  Br J Anaesth       Date:  2012-10-30       Impact factor: 9.166

3.  Comparison of venous sampling methods for thromboelastography in clinically normal dogs.

Authors:  Julie M Walker; Rita M Hanel; Bernard D Hansen; Alison A Motsinger-Reif
Journal:  Am J Vet Res       Date:  2012-12       Impact factor: 1.156

4.  Rapid and correct prediction of thrombocytopenia and hypofibrinogenemia with rotational thromboelastometry in cardiac surgery.

Authors:  Rik H G Olde Engberink; Gerhardus J A J M Kuiper; Rick J H Wetzels; Patty J Nelemans; Marcus D Lance; Erik A M Beckers; Yvonne M C Henskens
Journal:  J Cardiothorac Vasc Anesth       Date:  2014-04       Impact factor: 2.628

5.  Systematic evaluation of evidence on veterinary viscoelastic testing part 2: Sample acquisition and handling.

Authors:  Bente Flatland; Amy M Koenigshof; Elizabeth A Rozanski; Robert Goggs; Bo Wiinberg
Journal:  J Vet Emerg Crit Care (San Antonio)       Date:  2014 Jan-Feb

6.  Clot formation in canine whole blood as measured by rotational thromboelastometry is influenced by sample handling and coagulation activator.

Authors:  Stephanie A Smith; Maureen McMichael; Alyssa Galligan; Shir Gilor; Crystal M Hoh
Journal:  Blood Coagul Fibrinolysis       Date:  2010-10       Impact factor: 1.276

7.  Citrate storage affects Thrombelastograph analysis.

Authors:  V Camenzind; T Bombeli; B Seifert; M Jamnicki; D Popovic; T Pasch; D R Spahn
Journal:  Anesthesiology       Date:  2000-05       Impact factor: 7.892

8.  Serial Evaluation of Haemostasis Following Acute Trauma Using Rotational Thromboelastometry in Dogs.

Authors:  Yaiza Herrero; Rahel Jud Schefer; Benjamin M Muri; Nadja E Sigrist
Journal:  Vet Comp Orthop Traumatol       Date:  2020-11-17       Impact factor: 1.358

9.  Thromboelastometry and organ failure in trauma patients: a prospective cohort study.

Authors:  Marcella C A Müller; Kirsten Balvers; Jan M Binnekade; Nicola Curry; Simon Stanworth; Christine Gaarder; Knut M Kolstadbraaten; Claire Rourke; Karim Brohi; J Carel Goslings; Nicole P Juffermans
Journal:  Crit Care       Date:  2014-12-25       Impact factor: 9.097

10.  Hyperfibrinolysis and Hypofibrinogenemia Diagnosed With Rotational Thromboelastometry in Dogs Naturally Infected With Angiostrongylus vasorum.

Authors:  N E Sigrist; N Hofer-Inteeworn; R Jud Schefer; C Kuemmerle-Fraune; M Schnyder; A P N Kutter
Journal:  J Vet Intern Med       Date:  2017-05-07       Impact factor: 3.333

View more
  1 in total

1.  Comparison of Jugular vs. Saphenous Blood Samples, Intrarater and In-Between Device Reliability of Clinically Used ROTEM S Parameters in Dogs.

Authors:  Johanna Vuille-Dit-Bille; Nicole Weingand; Rahel Jud Schefer; Martina Stirn; Katja-Nicole Adamik; Justus M K Rathmann; Nadja E Sigrist
Journal:  Animals (Basel)       Date:  2022-08-17       Impact factor: 3.231

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.