Literature DB >> 22487300

Effect of venipuncture quality on thromboelastography.

Brandi L Garcia-Pereira1, Michael A Scott, Amy M Koenigshof, Andrew J Brown.   

Abstract

OBJECTIVE: To determine if the quality of venipuncture impacts thromboelastography (TEG) results and if an initial discard tube mitigates any effects of traumatic venipuncture.
DESIGN: Prospective, observational study.
SETTING: Veterinary teaching hospital. ANIMALS: Fifteen privately owned and research colony adult dogs. MEASUREMENTS: Samples were collected from each jugular vein using 1 of 2 venipuncture techniques per vein. The venipuncture technique was randomized to the vein as follows: (1) "clean" venipuncture (CV) from 1 jugular vein, and (2) suboptimal venipuncture (SOV) from the opposite jugular vein. CV was defined as a direct entry into the vein on the first attempt. SOV was defined as needle insertion adjacent to the vein with redirection at least once to enter the vein. Two consecutive samples were collected from each venipuncture without removal of the needle, yielding 4 samples: CV1, CV2, SOV1, and SOV2. TEG was performed on each blood sample and the TEG parameters R, K, α, and MA were recorded.
RESULTS: Mean ± SD of R for the SOV1 group (4.1 ± 1.3 s) was significantly shorter than that of the CV1 group (5.7 ± 1.4 s) and the SOV2 group (5.5 ± 1.9 s), P< 0.05. There was no difference in R between CV1 and CV2 groups, or between SOV2 and either CV1 or CV2. There was no significant difference in α, K, or MA among groups.
CONCLUSIONS: Mild-to-moderate venipuncture trauma had little effect on TEG overall, but R was significantly affected. Poorer quality collection resulted in a more rapid initiation of clot formation. However, the effect was mild and mitigated by testing samples in a second collection tube after discard of an initial sample. © Veterinary Emergency and Critical Care Society 2012.

Entities:  

Mesh:

Year:  2012        PMID: 22487300     DOI: 10.1111/j.1476-4431.2012.00724.x

Source DB:  PubMed          Journal:  J Vet Emerg Crit Care (San Antonio)        ISSN: 1476-4431


  6 in total

1.  Effects of tranexamic acid on coagulation indexes of patients undergoing heart valve replacement surgery under cardiopulmonary bypass.

Authors:  Fei Liu; Dong Xu; Kefeng Zhang; Jian Zhang
Journal:  Int J Immunopathol Pharmacol       Date:  2016-09-30       Impact factor: 3.219

2.  Evaluation of thromboelastography in two factor XII-deficient cats.

Authors:  Shauna L Blois; Marie K Holowaychuk; R Darren Wood
Journal:  JFMS Open Rep       Date:  2015-06-01

3.  ACVIM consensus statement on the diagnosis of immune-mediated hemolytic anemia in dogs and cats.

Authors:  Oliver A Garden; Linda Kidd; Angela M Mexas; Yu-Mei Chang; Unity Jeffery; Shauna L Blois; Jonathan E Fogle; Amy L MacNeill; George Lubas; Adam Birkenheuer; Simona Buoncompagni; Julien R S Dandrieux; Antonio Di Loria; Claire L Fellman; Barbara Glanemann; Robert Goggs; Jennifer L Granick; Dana N LeVine; Claire R Sharp; Saralyn Smith-Carr; James W Swann; Balazs Szladovits
Journal:  J Vet Intern Med       Date:  2019-02-26       Impact factor: 3.333

4.  Effect of dilution of canine blood samples on the specificity of saline agglutination tests for immune-mediated hemolysis.

Authors:  Prudence L Sun; Unity Jeffery
Journal:  J Vet Intern Med       Date:  2020-11-10       Impact factor: 3.333

5.  Evaluation of the Effect of Storage Time on ROTEM S® Parameters in Healthy and Ill Dogs.

Authors:  Nicole Weingand; Johanna Vuille-Dit-Bille; Rahel Jud Schefer; Annette P N Kutter; Martina Stirn; Katja-Nicole Adamik; Nadja E Sigrist
Journal:  Animals (Basel)       Date:  2022-08-07       Impact factor: 3.231

6.  Point-of-care viscoelastic coagulation assessment in healthy dogs during the perianesthetic period.

Authors:  Wen H Wang; Alex M Lynch; Julie A Balko; Daniel J Duffy; James B Robertson; Lysa P Posner
Journal:  BMC Vet Res       Date:  2022-09-14       Impact factor: 2.792

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.