Literature DB >> 31982776

Determination of reference intervals for single vial rotational thromboelastometry (ROTEM) parameters and correlation with plasmatic coagulation times in 49 clinically healthy dogs.

Rahel Jud Schefer1, Lara Heimgartner2, Martina Stirn3, Nadja E Sigrist4.   

Abstract

The objectives of this prospective study were determination of reference intervals (RI) for rotational thromboelastometry (ROTEM) parameters in single use reagents and to evaluate correlations between plasmatic coagulation times and ROTEM parameters. Blood was sampled from a jugular vein in 49 client-owned healthy dogs and ex-tem S, in-tem S, fib-tem S and ap-tem S parameters, prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen, haematology, blood chemistry and venous blood gas analysis was performed. Determination of RI was performed using Excel add-in Reference Value Advisor and correlations between PT, aPTT and fibrinogen with selected ROTEM parameters were determined by Spearman correlation. Ex-tem S maximum clot firmness (MCF) RI are smaller compared to RI in people and liquid ex-tem in dogs while maximum lysis was comparable to those in people but smaller than previously reported in dogs. A strong correlation was found between fibrinogen measured by Clauss and fib-tem S and in-tem S MCF (r = 0.541, P < .001 and r = 0.610, P < .001, respectively). PT showed a significant but moderate correlation with ex-tem S CT (r = 0.340, P = .030), in-tem S CFT (r = 0.433, P = .003), fib-tem S CT (r = 0.426, P = .009) and ap-tem S CT (r = 0.354, P = .015) while aPTT was not significantly correlated with any of the evaluated parameters. In conclusion, this study provides single use reagent ROTEM parameter RIs that are different from RI determined with liquid reagents. Significant correlations between fibrinogen concentrations measured by Clauss and clot firmness of fib-tem S and in-tem S profiles and between PT and clotting times of all reagents were identified.
Copyright © 2020 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Canine; Fibrinogen; PT; aPTT

Year:  2020        PMID: 31982776     DOI: 10.1016/j.rvsc.2020.01.014

Source DB:  PubMed          Journal:  Res Vet Sci        ISSN: 0034-5288            Impact factor:   2.534


  4 in total

1.  Whole blood platelet impedance aggregometry with the ROTEM platelet device: comparison of 2 anticoagulants and storage times for the establishment of canine reference intervals.

Authors:  Lara M Heimgartner; Martina Stirn; Annette P N Kutter; Nadja E Sigrist; Rahel Jud Schefer
Journal:  J Vet Diagn Invest       Date:  2021-10-15       Impact factor: 1.569

2.  Impact of general anesthesia on rotational thromboelastometry (ROTEM) parameters and standard plasmatic coagulation tests in healthy Beagle dogs.

Authors:  Andrea Schwarz; Louise F Martin; Francesca Del Chicca; Nadja E Sigrist; Annette Pn Kutter
Journal:  Vet Anim Sci       Date:  2021-12-04

3.  Evaluation of the Effect of Storage Time on ROTEM S® Parameters in Healthy and Ill Dogs.

Authors:  Nicole Weingand; Johanna Vuille-Dit-Bille; Rahel Jud Schefer; Annette P N Kutter; Martina Stirn; Katja-Nicole Adamik; Nadja E Sigrist
Journal:  Animals (Basel)       Date:  2022-08-07       Impact factor: 3.231

4.  Comparison of Jugular vs. Saphenous Blood Samples, Intrarater and In-Between Device Reliability of Clinically Used ROTEM S Parameters in Dogs.

Authors:  Johanna Vuille-Dit-Bille; Nicole Weingand; Rahel Jud Schefer; Martina Stirn; Katja-Nicole Adamik; Justus M K Rathmann; Nadja E Sigrist
Journal:  Animals (Basel)       Date:  2022-08-17       Impact factor: 3.231

  4 in total