| Literature DB >> 35941628 |
Pawinee Wiriyasatiankun1, Rangsima Sakoolnamarka2, Panida Thanyasrisung3.
Abstract
BACKGROUND: It has been claimed that an alkasite restorative material can neutralize acids produced by cariogenic bacteria from released hydrogen ions and enable to remineralization via calcium and fluoride ions. However, there is no evidence to support this assertion. Therefore, the aims of this study were to investigate the effect of the alkasite restorative material on the pH of Streptococcus mutans biofilm and dentin hardness.Entities:
Keywords: Alkasite; Biofilm; Hardness; Ion release; Streptococcus mutans
Mesh:
Substances:
Year: 2022 PMID: 35941628 PMCID: PMC9361645 DOI: 10.1186/s12903-022-02354-4
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 3.747
Restorative materials
| Material types | Compositions |
|---|---|
| Bis-GMA, BIS-EMA, UDMA, TEGDMA, particles of silica and zirconia/silane, BHT, photoinitiator, pigments |
UDMA urethane dimethacrylate, DCP triclodecan-dimethanol dimethacrylate, Aromatic aliphatic-UDMA tetramethyl-xylylen-diurethane dimethacrylate, PEG-400 DMA polyethylene glycol 400 dimethacrylate, Bis-GMA bisphenol A-glycidyl methacrylate, BIS-EMA bisphenol A-diglycidyl methacrylate ethoxylated, TEGDMA triethylene glycol dimethacrylate, BHT butylated hydroxytoluene
Fig. 1Flow diagram illustrating the determination of biofilm pH and ion release
Fig. 2Specimen preparation. Q1 sound dentin; Q3 demineralized dentin control; Q2, and Q4 chemically demineralized dentin with FZ and CN placed on their respective surfaces
Fig. 3Microhardness measurement
Fig. 4The pH of S. mutans biofilm formed on Filtek™ Z350XT (FZ) and Cention® N (CN) specimens. Each dot represents the pH of a specimen
Fig. 5The mean of cumulative hydroxide ions released from Filtek™ Z350XT (FZ; Black filled circle) and Cention® N (CN; Black filled triangle) at six time points (6 h, 1, 3, 7, 14 and 28 days)
Fig. 6The means cumulative fluoride ions released from Filtek™ Z350XT (FZ; Black filled circle) and Cention® N (CN; Black filled triangle) at six time points (6 h, 1, 3, 7, 14 and 28 days)
Fig. 7The mean cumulative calcium ions released from Filtek™ Z350XT (FZ; Black filled circle) and Cention® N (CN; Black filled triangle) at six time points (6 h, 1, 3, 7, 14 and 28 days)
Fig. 8Mean value of Knoop hardness number (KHN) of dentin specimens at different depths