Literature DB >> 12664469

Determining low levels of fluoride released from resin based dental materials.

John F McCabe1, Thomas E Carrick, Sharanbir K Sidhu.   

Abstract

Fluoride release determinations were made on two resin matrix dentine bonding systems using an ion-selective electrode and ion chromatography. Calibrations were made on serially diluted samples of standard fluoride solutions. The electrode method consistently gave higher values than the chromatographic method for one of the materials, and this was considered to be due to the use of total ionic strength adjustment buffer in electrode determinations. The lower limit of fluoride determination using the electrode was 0.5-0.1 p.p.m. Below this concentration the output from the electrode became meaningless. The chromatographic method gave meaningful results down to 0.001 p.p.m. The fluoride release results for the meter were meaningful only for the first 2 d for one test material and for up to 10 d for the other material. Using chromatography, fluoride release could be monitored for the full 44 d of the trial for both materials. Over the range of concentrations where fluoride determinations were possible by both methods, the values were correlated (R = 0.98). Ion chromatography appears to have an advantage over the ion-selective electrode for measuring low levels of fluoride release from dental materials.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12664469     DOI: 10.1034/j.1600-0722.2002.21275.x

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  6 in total

1.  In vitro and in vivo assessment of newly developed slow-release fluoride glass device.

Authors:  N S Al Ibrahim; J F Tahmassebi; K J Toumba
Journal:  Eur Arch Paediatr Dent       Date:  2010-06

2.  Fluoride-Releasing Effect of a Modified Resin Denture Containing S-PRG Fillers on Salivary Fluoride Retention: A Randomized Clinical Study.

Authors:  Kritirat Kiatsirirote; Thanya Sitthisettapong; Prathip Phantumvanit; Daniel C N Chan
Journal:  Caries Res       Date:  2018-07-27       Impact factor: 4.056

3.  The impact of an alkasite restorative material on the pH of Streptococcus mutans biofilm and dentin remineralization: an in vitro study.

Authors:  Pawinee Wiriyasatiankun; Rangsima Sakoolnamarka; Panida Thanyasrisung
Journal:  BMC Oral Health       Date:  2022-08-08       Impact factor: 3.747

4.  A comparative in vitro study on fluoride release and water sorption of different flowable esthetic restorative materials.

Authors:  Asmaa Youssif Harhash; Iman Ibrahim ElSayad; Ahmad G S Zaghloul
Journal:  Eur J Dent       Date:  2017 Apr-Jun

5.  Effect of casein phosphopeptide-amorphous calcium phosphate on fluoride release and micro-shear bond strength of resin-modified glass ionomer cement in caries-affected dentin.

Authors:  Jamila Nuwayji Agob; Neven Saad Aref; Essam El Saeid Al-Wakeel
Journal:  Restor Dent Endod       Date:  2018-10-30

6.  Effect of fluoride slow-release glass devices on salivary and gingival crevicular fluid levels of fluoride: A pilot study.

Authors:  Chrysoula Tatsi; Kyriacos Jack Toumba
Journal:  Clin Exp Dent Res       Date:  2019-07-28
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.