| Literature DB >> 35927621 |
Yu Chen1, Ziyou Liu1, Min Zhang1, Jia Yang2, Jun Fang1, Yanhu Xie1.
Abstract
BACKGROUND: Accurate assessment of volume responsiveness in elderly patients is important as it may reduce the risk of post-operative complications and enhance surgical recovery. This study evaluated the utility of two Doppler ultrasound-derived parameters, the carotid corrected flow time (FTc) and respirophasic variation in carotid artery blood flow peak velocity (ΔVpeak), to predict volume responsiveness in elderly patients under general anaesthesia.Entities:
Keywords: Carotid Doppler ultrasound; Corrected flow time; Respirophasic variation; Stroke volume variation
Mesh:
Year: 2022 PMID: 35927621 PMCID: PMC9351080 DOI: 10.1186/s12871-022-01792-5
Source DB: PubMed Journal: BMC Anesthesiol ISSN: 1471-2253 Impact factor: 2.376
Fig. 1Carotid FTc and ΔVpeak measurement with Doppler ultrasound.Time C is FT.FTc carotid corrected flow time,ΔVpeak respirophasic variation in carotid artery blood flow peak velocity,FT flow time
Fig. 2Flow diagram of patient enrolment.SVV stroke volume variation
Patient baseline characteristics and haemodynamic parameters
| Male/female | 61/36 | 25/16 | 36/20 | 0.83b |
| Age, y | 71.6(65–88) | 71.2(65–84) | 71.9(65–88) | 0.50c |
| BMI, kg/m2 | 23.0 ± 2.5 | 23.2 ± 2.6 | 22.8 ± 2.5 | 0.37a |
| ASA PS I/II/III | 16/52/29 | 6/20/15 | 10/32/14 | 0.47b |
| Diagnosis | ||||
| Stomach tumour | 26 | 12 | 14 | 0.64b |
| Intestinal tumour | 63 | 27 | 36 | 1.00b |
| Enterostomy closure | 8 | 2 | 6 | 0.46b |
| Type of surgery | ||||
| Laparoscopic surgery | 89 | 39 | 50 | 0.26b |
| Open surgery | 8 | 2 | 6 | 0.26b |
| Comorbidities | ||||
| Hypertension | 18 | 8 | 10 | 1.00b |
| Diabetes mellitus | 7 | 3 | 4 | 1.00b |
| Coronary artery disease | 3 | 2 | 1 | 0.57b |
| Baseline SBP, mmHg | 130.9 ± 10.7 | 129.8 ± 12.0 | 131.6 ± 9.8 | 0.42a |
| Baseline DBP, mmHg | 71.0 ± 8.1 | 71 ± 8.6 | 70.9 ± 7.8 | 0.95a |
| Baseline MAP, mmHg | 90.9 ± 7.9 | 90.5 ± 7.8 | 91.2 ± 8.1 | 0.66a |
| Baseline HR, beats/min | 69.2 ± 9.0 | 68.7 ± 10.1 | 69.6 ± 8.3 | 0.65a |
| Baseline carotid FTc, ms | 343.2 ± 10.1 | 337.2 ± 9.1 | 347.6 ± 8.5 | < 0.001a |
| Baseline ΔVpeak, % | 10.7 ± 2.3 | 12.4 ± 1.8 | 9.5 ± 1.8 | < 0.001a |
Data are presented as the mean (standard deviation) or median (interquartile range)
a Independent-sample t test
b χ2 test
c Mann–Whitney U test
BMI Body mass index, ASA PS American Society of Anesthesiologists physical status, SBP systolic blood pressure, DBP diastolic blood pressure, MAP mean arterial pressure, HR heart rate, FTc carotid corrected flow time, ΔVpeak respirophasic variation in carotid artery blood flow peak velocity
Fig. 3Haemodynamic data(MAP,HR) in two groups at T0,T1 and T2.MAP mean arterial pressure,HR heart rate, T0 before general anaesthesia,T1 5 min after tracheal intubation,T2 5 min after completion of the fluid challenge
Haemodynamic variables at T1 and T2
| SVV (%) | 14.7(13–21) | 9.1(4–13) a | 10.5(6–14) b | 6.5(2–11) ab |
| FTc (ms) | 332.6 ± 9.9 | 356.4 ± 8.8a | 344.2 ± 10.4b | 363.6 ± 8.2ab |
| ΔVpeak (%) | 13.1 ± 2.2 | 8.9 ± 1.5a | 10.8 ± 2.2b | 7.2 ± 1.8ab |
Data are presented as the mean (standard deviation) or median (interquartile range)
a P < 0.05 vs. T1
b P < 0.05 vs. responders
T1 5 min after tracheal intubation,T2 5 min after completion of the fluid challenge, SVV stroke volume variation
Fig. 4The relationship between SVV and FTc or ΔVpeak at T1.Trend lines are presented as solid lines.SVV stroke volume variation,FTc carotid corrected flow time,ΔVpeak respirophasic variation in carotid artery blood flow peak velocity,T1 5 min after tracheal intubation
Fig. 5Area under the receiver operating characteristic curve of the carotid FTc and ΔVpeak to predict the ability of SVV ≥ 13%.Shaded area represents 95% confidence interval.FTc carotid corrected flow time,ΔVpeak respirophasic variation in carotid artery blood flow peak velocity,SVV stroke volume variation
Diagnostic performance of carotid FTc and ΔVpeak to predict the ability of SVV ≥ 13%
| Parameter | AUROC | Best Cut-off | grey zone | Patients in grey zone(%) | Sensitivity | Specificity | Youden | |
|---|---|---|---|---|---|---|---|---|
| FTc | 0.811(0.721–0.900) | < 0.01 | 340.74 | 331.44–345.90 | 47.4 | 76.8 | 80.5 | 0.57 |
| ΔVpeak | 0.781(0.686–0.875) | < 0.01 | 11.69 | 9.97–13.42 | 48.5 | 78 | 67.9 | 0.48 |
AUROC Area under the receiver operating characteristic curve, FTc Carotid corrected flow time, ΔVpeak Respirophasic variation in carotid artery blood flow peak velocity