Literature DB >> 27922879

The Changes in Pulse Pressure Variation or Stroke Volume Variation After a "Tidal Volume Challenge" Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation.

Sheila Nainan Myatra1, Natesh R Prabu, Jigeeshu Vasishtha Divatia, Xavier Monnet, Atul Prabhakar Kulkarni, Jean-Louis Teboul.   

Abstract

OBJECTIVES: Stroke volume variation and pulse pressure variation do not reliably predict fluid responsiveness during low tidal volume ventilation. We hypothesized that with transient increase in tidal volume from 6 to 8 mL/kg predicted body weight, that is, "tidal volume challenge," the changes in pulse pressure variation and stroke volume variation will predict fluid responsiveness.
DESIGN: Prospective, single-arm study.
SETTING: Medical-surgical ICU in a university hospital. PATIENTS: Adult patients with acute circulatory failure, having continuous cardiac output monitoring, and receiving controlled low tidal volume ventilation.
INTERVENTIONS: The pulse pressure variation, stroke volume variation, and cardiac index were recorded at tidal volume 6 mL/kg predicted body weight and 1 minute after the "tidal volume challenge." The tidal volume was reduced back to 6 mL/kg predicted body weight, and a fluid bolus was given to identify fluid responders (increase in cardiac index > 15%). The end-expiratory occlusion test was performed at tidal volumes 6 and 8 mL/kg predicted body weight and after reducing tidal volume back to 6 mL/kg predicted body weight.
RESULTS: Thirty measurements were obtained in 20 patients. The absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mL/kg predicted body weight predicted fluid responsiveness with areas under the receiver operating characteristic curves (with 95% CIs) being 0.99 (0.98-1.00) and 0.97 (0.92-1.00), respectively. The best cutoff values of the absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mL/kg predicted body weight were 3.5% and 2.5%, respectively. The pulse pressure variation, stroke volume variation, central venous pressure, and end-expiratory occlusion test obtained during tidal volume 6 mL/kg predicted body weight did not predict fluid responsiveness.
CONCLUSIONS: The changes in pulse pressure variation or stroke volume variation obtained by transiently increasing tidal volume (tidal volume challenge) are superior to pulse pressure variation and stroke volume variation in predicting fluid responsiveness during low tidal volume ventilation.

Entities:  

Mesh:

Year:  2017        PMID: 27922879     DOI: 10.1097/CCM.0000000000002183

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  37 in total

Review 1.  Cardiopulmonary Interactions: Physiologic Basis and Clinical Applications.

Authors:  Michael R Pinsky
Journal:  Ann Am Thorac Soc       Date:  2018-02

2.  Update on the assessment of fluid responsiveness.

Authors:  Koichi Suehiro
Journal:  J Anesth       Date:  2020-01-07       Impact factor: 2.078

3.  Tidal volume challenge to predict preload responsiveness in patients with acute respiratory distress syndrome under prone position.

Authors:  Rui Shi; Soufia Ayed; Francesca Moretto; Danila Azzolina; Nello De Vita; Francesco Gavelli; Simone Carelli; Arthur Pavot; Christopher Lai; Xavier Monnet; Jean-Louis Teboul
Journal:  Crit Care       Date:  2022-07-18       Impact factor: 19.334

Review 4.  Alternatives to the Swan-Ganz catheter.

Authors:  Daniel De Backer; Jan Bakker; Maurizio Cecconi; Ludhmila Hajjar; Da Wei Liu; Suzanna Lobo; Xavier Monnet; Andrea Morelli; Sheila Neinan Myatra; Azriel Perel; Michael R Pinsky; Bernd Saugel; Jean-Louis Teboul; Antoine Vieillard-Baron; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2018-05-03       Impact factor: 17.440

Review 5.  Prediction of fluid responsiveness in ventilated patients.

Authors:  Mathieu Jozwiak; Xavier Monnet; Jean-Louis Teboul
Journal:  Ann Transl Med       Date:  2018-09

Review 6.  Resuscitation fluids.

Authors:  Jonathan D Casey; Ryan M Brown; Matthew W Semler
Journal:  Curr Opin Crit Care       Date:  2018-12       Impact factor: 3.687

7.  A robust Fourier-based method to measure pulse pressure variability.

Authors:  Sebastian Acosta; Mubbasheer Ahmed; Suellen M Yin; Ken M Brady; Daniel J Penny; Craig G Rusin
Journal:  Biomed Signal Process Control       Date:  2020-04-17       Impact factor: 3.880

8.  Change in cardiac output during Trendelenburg maneuver is a reliable predictor of fluid responsiveness in patients with acute respiratory distress syndrome in the prone position under protective ventilation.

Authors:  Hodane Yonis; Laurent Bitker; Mylène Aublanc; Sophie Perinel Ragey; Zakaria Riad; Floriane Lissonde; Aurore Louf-Durier; Sophie Debord; Florent Gobert; Romain Tapponnier; Claude Guérin; Jean-Christophe Richard
Journal:  Crit Care       Date:  2017-12-05       Impact factor: 9.097

9.  The influence of positive end-expiratory pressure (PEEP) in predicting fluid responsiveness in patients undergoing one-lung ventilation.

Authors:  In-Jung Jun; Mi Hwa Chung; Jung Eun Kim; Hye Sun Lee; Jung Mo Son; Eun Mi Choi
Journal:  Int J Med Sci       Date:  2021-04-29       Impact factor: 3.738

Review 10.  Perioperative fluid management: From physiology to improving clinical outcomes.

Authors:  Victoria A Bennett; Maurizio Cecconi
Journal:  Indian J Anaesth       Date:  2017-08
View more