Literature DB >> 35925545

Clinical implementation of kVCT-guided tomotherapy with ClearRT.

Bin Yang1, Hui Geng2, Tien Yee Amy Chang3, Mei Yan Tse2, Wai Wang Lam2, Chen-Yu Huang2, Tungho Wu4, Ka Ki Lau2, Kin Yin Cheung2, George Chiu5, Siu Ki Yu2.   

Abstract

A helical fan-beam kilovoltage computed tomography (kVCT) was recently introduced into Tomotherapy units. This study aims to share the initial experience of kVCT in clinical workflow, compare its performance with that of the existing megavoltage computed tomography (MVCT), and explore its potential in adaptive planning. We retrospectively enrolled 23 patients who underwent both MVCT and kVCT scans. The clinical performance data regarding image acquisition time, nominal dose length product (DLP), registration time and registration corrections were extracted and compared. Image quality was scored by six experienced radiation therapists and quantified based on phantom measurements. CT number stability and the implementation of adaptive radiotherapy were dosimetrically evaluated by performing the dose recalculation on kVCT. Compared to MVCT, kVCT significantly reduced DLP (except the highest kVp protocol), image acquisition and registration time. KVCT obtained higher scores than MVCT on all criteria except artifacts. Phantom measurements also revealed a better image performance characterization of kVCT except for image uniformity. The CT number variation could lead to a dose difference of 0.5% for D95% of target and Dmean of organ-at-risk. For the treatment planning with kVCT, a systematic dose difference (> 1%) in PTV dose metrics was observed at regions with large longitudinal density discontinuities compared to the reference plans. The new kVCT imaging provides enhanced soft-tissue visualization. The improved efficiency with kVCT-guided treatment will allow more patients to be treated each day. In most cases, the dose calculation accuracy of kVCT images is acceptable except for regions with severe artifacts.
© 2022. Australasian College of Physical Scientists and Engineers in Medicine.

Entities:  

Keywords:  ClearRT; Dosimetric evaluation; Image quality; Radixact; Tomotherapy; kVCT

Mesh:

Year:  2022        PMID: 35925545     DOI: 10.1007/s13246-022-01162-y

Source DB:  PubMed          Journal:  Phys Eng Sci Med        ISSN: 2662-4729


  9 in total

1.  Tomotherapy.

Authors:  T R Mackie; J Balog; K Ruchala; D Shepard; S Aldridge; E Fitchard; P Reckwerdt; G Olivera; T McNutt; M Mehta
Journal:  Semin Radiat Oncol       Date:  1999-01       Impact factor: 5.934

2.  Tolerance levels for quality assurance of electron density values generated from CT in radiotherapy treatment planning.

Authors:  Warren Kilby; John Sage; Vicki Rabett
Journal:  Phys Med Biol       Date:  2002-05-07       Impact factor: 3.609

Review 3.  Helical tomotherapy: an innovative technology and approach to radiation therapy.

Authors:  James S Welsh; Rakesh R Patel; Mark A Ritter; Paul M Harari; T Rockwell Mackie; Minesh P Mehta
Journal:  Technol Cancer Res Treat       Date:  2002-08

4.  Delineation of moving targets with slow MVCT scans: implications for adaptive non-gated lung tomotherapy.

Authors:  Christopher Smeenk; Stewart Gaede; Jerry J Battista
Journal:  Phys Med Biol       Date:  2007-01-25       Impact factor: 3.609

Review 5.  Artefacts in CBCT: a review.

Authors:  R Schulze; U Heil; D Gross; D D Bruellmann; E Dranischnikow; U Schwanecke; E Schoemer
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

6.  Image quality and dose evaluation of MVCT TomoTherapy acquisitions: A phantom study.

Authors:  P De Marco; I Abdi Osman; F Castellini; R Ricotti; M C Leonardi; E Miglietta; R Cambria; D Origgi; B A Jereczek-Fossa; C Garibaldi; F Cattani
Journal:  Phys Med       Date:  2019-01-15       Impact factor: 2.685

Review 7.  Megavoltage CT images of helical tomotherapy unit for radiation treatment simulation: impact on feasibility of treatment planning in a prostate cancer patient with bilateral femoral prostheses.

Authors:  Filippo Alongi; Andrei Fodor; Angelo Maggio; Cesare Cozzarini; Claudio Fiorino; Sara Broggi; Pierpaolo Alongi; Riccardo Calandrino; Nadia Di Muzio
Journal:  Tumori       Date:  2011 Mar-Apr

8.  Utility of megavoltage fan-beam CT for treatment planning in a head-and-neck cancer patient with extensive dental fillings undergoing helical tomotherapy.

Authors:  Claus Yang; Tianxiao Liu; Richard L Jennelle; Janice K Ryu; Srinivasan Vijayakumar; James A Purdy; Allen M Chen
Journal:  Med Dosim       Date:  2009-04-22       Impact factor: 1.482

9.  Clinical Assessment of a Novel Ring Gantry Linear Accelerator-Mounted Helical Fan-Beam kVCT System.

Authors:  Christian Velten; Lee Goddard; Kyoungkeun Jeong; Madhur K Garg; Wolfgang A Tomé
Journal:  Adv Radiat Oncol       Date:  2021-12-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.