Delineation of moving targets with slow MVCT scans: implications for adaptive non-gated lung tomotherapy.

Christopher Smeenk1, Stewart Gaede, Jerry J Battista.   

Abstract

Accurate imaging is a prerequisite for adaptive radiation therapy of mobile tumours. We present an evaluation of the performance of slow computed tomography (CT) for mapping and delineating the excursion boundary of a moving object using a tumour phantom scanned with the helical MVCT scanner of a tomotherapy unit. A spherical test object driven by sinusoidal motion in both the lateral and cranial-caudal directions was used to determine how well MVCT images depict the true envelope of the motion. Such information is useful in interpreting the CT images relative to the static object case when radiotherapy gating is to be used or in determining the internal target volume (ITV) when beam gating is not possible. A computer simulation of the CT imaging process was developed which incorporates the third generation fan beam geometry and helical acquisition technique of the tomotherapy MVCT system. Motion artefacts are mainly characterized by the parameter alpha=Tgantry/Trespiration which is interpreted as the period of the gantry rotation (Tgantry) in units of the respiratory period (Trespiration). Experimental tests were performed using a fixed gantry period of 10 s per full rotation and respiratory period ranging from 4.0 (alpha=2.5) to 1.0 (alpha=10) s. These cases represent typical clinical imaging conditions on the tomotherapy unit, as well as an extreme test case where the gantry period is intentionally set to be much greater than the respiratory period (termed an 'ultra-slow' scan). The accuracy of target (ITV) delineation is evaluated by comparing volumes generated using iso-density contours on the MVCT images to the true motion envelope, known a priori in this phantom study. As expected, motion artefacts are present in clinical MVCT images and they are not averaged over the slow gantry period of rotation. Furthermore, artefacts are not significantly affected by scanning with different helical pitch values. Greater distortions from the true density distribution are observed for lateral motion compared to cranial-caudal motion. Volumes generated by iso-density contours yield better agreement with the motion envelope for scans performed under ultra-slow conditions (alpha=10) compared to typical clinical imaging conditions (alpha=2.5). If the MVCT gantry cannot be rotated very quickly due to engineering constraints in order to achieve ultra-fast CT, we suggest an opposite approach as an interim measure for mapping the ITV. Adjusting MVCT scan conditions to a very slow acquisition (alpha=10) may be a good compromise for determining the ITV for non-gated adaptive tomotherapy of moving lung tumours.

Entities:  

Mesh:

Year:  2007        PMID: 17264374     DOI: 10.1088/0031-9155/52/4/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Treatment outcomes and patterns of radiologic appearance after hypofractionated image-guided radiotherapy delivered with helical tomotherapy (HHT) for lung tumours.

Authors:  Stefano Arcangeli; Lorenzo Falcinelli; Stefano Bracci; Alessandro Greco; Alessia Monaco; Jessica Dognini; Cinzia Chiostrini; Rita Bellavita; Cynthia Aristei; Vittorio Donato
Journal:  Br J Radiol       Date:  2017-03       Impact factor: 3.039

2.  Clinical implementation of kVCT-guided tomotherapy with ClearRT.

Authors:  Bin Yang; Hui Geng; Tien Yee Amy Chang; Mei Yan Tse; Wai Wang Lam; Chen-Yu Huang; Tungho Wu; Ka Ki Lau; Kin Yin Cheung; George Chiu; Siu Ki Yu
Journal:  Phys Eng Sci Med       Date:  2022-08-04

3.  On-line target position localization in the presence of respiration: a comparison of two methods.

Authors:  Geoffrey D Hugo; Jian Liang; Jonathan Campbell; Di Yan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-10-29       Impact factor: 7.038

4.  A comprehensive assessment by tumor site of patient setup using daily MVCT imaging from more than 3,800 helical tomotherapy treatments.

Authors:  Leah K Schubert; David C Westerly; Wolfgang A Tomé; Minesh P Mehta; Emilie T Soisson; Thomas R Mackie; Mark A Ritter; Deepak Khuntia; Paul M Harari; Bhudatt R Paliwal
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-03-15       Impact factor: 7.038

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.