| Literature DB >> 35909991 |
Tugba Çetinkaya1, Muhammed Mustafa Kurt2.
Abstract
Background: We aimed to compare optical biometric measurements using optical biometry in patients with previously received COVID-19 treatment and a control group.Entities:
Keywords: ACE‑2 receptor; Biometry; Cornea; Favipiravir; SARS-CoV‑2
Year: 2022 PMID: 35909991 PMCID: PMC9315324 DOI: 10.1007/s00717-022-00526-9
Source DB: PubMed Journal: Spektrum Augenheilkd ISSN: 0930-4282
Optical biometric results for the patients in the COVID-19 group and the healthy control group
| Parameters | COVID-19 group | Control group | |
|---|---|---|---|
| K_2.4 mm (D) | 43.18 ± 1.45 | 43.09 ± 1.69 | 0.79 |
| K_3.3 mm (D) | 43.14 ± 1.44 | 43.04 ± 1.68 | 0.77 |
| Corneal astigmatism_2.4 mm (D) | 0.78 ± 0.44 | 0.70 ± 0.37 | 0.41 |
| Corneal astigmatism_3.3 mm (D) | 0.72 ± 0.41 | 0.71 ± 0.36 | 0.95 |
| AL (mm) | 23.37 ± 0.77 | 23.36 ± 0.73 | 0.96 |
| ACD (mm) | 3.36 ± 0.33 | 3.32 ± 0.22 | 0.59 |
| CCT (μm) | 552.80 ± 36.77 | 559.25 ± 26.83 | 0.37 |
K_2.4 keratometric measurements obtained from central 2.4 mm of the cornea, K_3.3 keratometric measurements obtained from central 3.3 mm of the cornea, COVID-19 Coronavirus disease 19, AL axial length, ACD anterior chamber depth, CCT central corneal thickness, D diopter
Fig. 1Distribution of optical biometrical measurements between COVID-19 group and healthy control group
Chi-square correlation test between COVID-19 and healthy individuals for keratometric measurements obtained from 2.4 mm of the cornea
| The type of astigmatism_2.4 | Total | χ2 | SD | ||||||
|---|---|---|---|---|---|---|---|---|---|
| With the rule | Against the rule | Oblique | |||||||
| 99 | 31 | 63 | 193 | 7.449 | 2 | 0.024 | |||
| % | 44.9 | 100 | 51.9 | 51.8 | |||||
| 130 | 0 | 63 | 193 | ||||||
| % | 55.1 | 0 | 48.1 | 48.2 | |||||
| 229 | 31 | 126 | 386 | ||||||
| % | 100 | 100 | 100 | 100 | |||||
COVID-19 Coronavirus disease 19, SD standard deviation
Chi-square correlation test between COVID-19 and healthy individuals for keratometric measurements obtained from 3.3 mm of the cornea
| The type of astigmatism_3.3 | Total | χ2 | SD | ||||||
|---|---|---|---|---|---|---|---|---|---|
| With the rule | Against the rule | Oblique | |||||||
| 103 | 18 | 72 | 193 | 4.528 | 2 | 0.104 | |||
| % | 46 | 100 | 55.2 | 51.8 | |||||
| 130 | 0 | 63 | 193 | ||||||
| % | 54 | 0 | 44.8 | 48.2 | |||||
| 233 | 18 | 135 | 193 | ||||||
| % | 100 | 100 | 100 | 100 | |||||
COVID-19 Coronavirus disease 19, SD standard deviation
Fig. 2Distribution of optical biometrical measurements with male and female gender in patients with COVID-19
Subgroup analysis by gender for all measured values in patients with COVID-19
| Parameters | Mean ± SD | ||
|---|---|---|---|
| Female | Male | ||
| K_2.4 (D) | 43.38 ± 1.53 | 42.74 ± 1.37 | 0.33 |
| C_ast_2.4 (D) | 0.71 ± 0.43 | 0.69 ± 0.54 | 0.93 |
| K_3.3 (D) | 43.31 ± 1.56 | 42.75 ± 1.41 | 0.39 |
| C_ast_3.3 (D) | 0.77 ± 0.36 | 0.60 ± 0.50 | 0.39 |
| AL (mm) | 23.01 ± 0.79 | 24.12 ± 0.67 | 0.02 |
| ACD (mm) | 3.18 ± 0.28 | 3.54 ± 0.31 | 0.001 |
| CCT (μm) | 540.70 ± 27.20 | 571.40 ± 32.00 | 0.02 |
K_2.4 keratometric measurements obtained from central 2.4 mm of the cornea, C_ast_2.4 corneal astigmatism obtained from central 2.4 mm of the cornea, K_3.3 keratometric measurements obtained from central 3.3 mm of the cornea, C_ast_3.3 corneal astigmatism obtained from central 3.3 mm of the cornea, COVID-19 Coronavirus disease 19, AL axial length, ACD anterior chamber depth, CCT central corneal thickness, D diopter
Subgroup analysis by gender for all measured values in the healthy individuals
| Parameters | Mean ± SD | ||
|---|---|---|---|
| Female | Male | ||
| K_2.4 (D) | 43.65 ± 1.89 | 42.24 ± 0.98 | 0.07 |
| C_ast_2.4 (D) | 0.80 ± 0.36 | 0.83 ± 0.16 | 0.08 |
| K_3.3 (D) | 43.59 ± 1.83 | 42.18 ± 1.00 | 0.06 |
| C_ast_3.3 (D) | 0.83 ± 0.38 | 0.82 ± 0.20 | 0.76 |
| AL (mm) | 23.05 ± 0.63 | 23.21 ± 0.64 | 0.46 |
| ACD (mm) | 3.30 ± 0.18 | 3.37 ± 0.29 | 0.55 |
| CCT (μm) | 560.25 ± 20.99 | 556.37 ± 35.54 | 0.76 |
K_2.4 keratometric measurements obtained from central 2.4 mm of the cornea, C_ast_2.4 corneal astigmatism obtained from central 2.4 mm of the cornea, K_3.3 keratometric measurements obtained from central 3.3 mm of the cornea, C_ast_3.3 corneal astigmatism obtained from central 3.3 mm of the cornea, AL axial length, ACD anterior chamber depth, CCT central corneal thickness, D diopter
Fig. 3Distribution of optical biometrical measurements with male and female gender in the healthy control group