Literature DB >> 28566392

Mid-term results of the BIOLOX delta ceramic-on-ceramic total hip arthroplasty.

Y K Lee1, Y C Ha2, J-I Yoo3, W L Jo4, K-C Kim5, K H Koo1.   

Abstract

AIMS: We conducted a prospective study of a delta ceramic total hip arthroplasty (THA) to determine the rate of ceramic fracture, to characterise post-operative noise, and to evaluate the mid-term results and survivorship. PATIENTS AND METHODS: Between March 2009 and March 2011, 274 patients (310 hips) underwent cementless THA using a delta ceramic femoral head and liner. At each follow-up, clinical and radiological outcomes were recorded. A Kaplan-Meier analysis was undertaken to estimate survival.
RESULTS: Four patients (four hips) died and 18 patients (20 hips) were lost to follow-up within five years. The remaining 252 patients (286 hips) were followed for a mean of 66.5 months (60 to 84). There were 144 men (166 hips) and 108 women (120 hips) with a mean age of 49.7 years (16 to 83) at surgery. The mean pre-operative Harris Hip Score of 47.1 points improved to 93.8 points at final follow-up. Six patients reported squeaking in seven hips; however, none were audible. Radiolucent lines involving Gruen zones one and/or seven were seen in 52 hips (18.2%). No hip had detectable wear, focal osteolysis or signs of loosening. One hip was revised because of fracture of the ceramic liner, which occurred due to an undetected malseating of the ceramic liner at the time of surgery. One hip was revised for a periprosthetic fracture of the femur, and one hip was treated for periprosthetic joint infection. The six-year survivorship with re-operation for any reason as the endpoint was 99.0% (95% confidence interval 97.8% to 100%). DISCUSSION: The rate of delta ceramic fracture was 0.3% (one of 286). While ceramic head fracture was dominant in previous ceramic-on-ceramic THA, fracture of the delta ceramic liner due to malseating is a concern. Cite this article: Bone Joint J 2017;99-B:741-8. ©2017 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  BIOLOX delta; Ceramic-on-ceramic; Implant fracture; Total hip arthroplasty

Mesh:

Year:  2017        PMID: 28566392     DOI: 10.1302/0301-620X.99B6.BJJ-2016-0486.R3

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  11 in total

1.  Third generation delta ceramic-on-ceramic bearing for total hip arthroplasty at mid-term follow-up.

Authors:  Alessandro Bistolfi; Riccardo Ferracini; Alessandro Aprato; Alessandro Massè; Walter Daghino; Sara Lea; Stefano Artiaco; Gwo-Chin Lee
Journal:  J Orthop       Date:  2020-08-28

2.  Third and fourth generation ceramic-on-ceramic total hip arthroplasty at a minimum of ten years.

Authors:  Cathal J McCarthy; John Mahon; Gerard A Sheridan; Adanna Welch-Phillips; John M O'Byrne; Paddy J Kenny
Journal:  J Clin Orthop Trauma       Date:  2022-07-06

3.  Surgeons' Awareness and Impaction Technique of a Ceramic Liner into a Metal Shell.

Authors:  Hong Seok Kim; Jung-Wee Park; Young-Kyun Lee; Alessandro Alan Porporati; Yong-Chan Ha; Kyung-Hoi Koo
Journal:  Clin Orthop Surg       Date:  2022-05-13

4.  Third-generation pure alumina and alumina matrix composites in total hip arthroplasty: What is the evidence?

Authors:  Didier Hannouche; Matthieu Zingg; Hermes Miozzari; Remy Nizard; Anne Lübbeke
Journal:  EFORT Open Rev       Date:  2018-01-10

5.  Squeaking in fourth-generation ceramic-on-ceramic total hip replacement and the relationship with prosthesis brands: meta-analysis and systematic review.

Authors:  Chen-Chen Zhao; Guo-Xin Qu; Shi-Gui Yan; Xun-Zi Cai
Journal:  J Orthop Surg Res       Date:  2018-06-01       Impact factor: 2.359

6.  Total Hip Arthroplasty Using Hybrid Ceramic Bearing: A Minimum 10-Year Followup Study.

Authors:  Jun-Il Yoo; Yong-Chan Ha; Dong-Hyun Kim; Young-Kyun Lee; Kyung-Hoi Koo
Journal:  Indian J Orthop       Date:  2019 Sep-Oct       Impact factor: 1.251

7.  Fourth-Generation Ceramic-on-Ceramic THA in Patients with Ankylosing Spondylitis: A Minimum 10-Year Follow-Up.

Authors:  Liangliang Li; Jun Fu; Chi Xu; Ming Ni; Wei Chai; Libo Hao; Yonggang Zhou; Jiying Chen
Journal:  Orthop Surg       Date:  2022-04-18       Impact factor: 2.279

Review 8.  Osteonecrosis of the Femoral Head: an Updated Review of ARCO on Pathogenesis, Staging and Treatment.

Authors:  Jeremy T Hines; Woo Lam Jo; Quanjun Cui; Michael A Mont; Kyung Hoi Koo; Edward Y Cheng; Stuart B Goodman; Yong Chan Ha; Phillippe Hernigou; Lynne C Jones; Shin Yoon Kim; Takashi Sakai; Nobuhiko Sugano; Takuaki Yamamoto; Mel S Lee; Dewei Zhao; Wolf Drescher; Tae Young Kim; Young Kyun Lee; Byung Ho Yoon; Seung Hoon Baek; Wataru Ando; Hong Seok Kim; Jung Wee Park
Journal:  J Korean Med Sci       Date:  2021-06-21       Impact factor: 2.153

9.  Ceramic Liner Fracture Caused by an Impingement between the Stem Shoulder and the Ceramic Liner.

Authors:  Sunhyung Lee; Seung Won Jeon; Jeong Joon Yoo; Hee Joong Kim
Journal:  Hip Pelvis       Date:  2020-09-02

10.  The reasons for ceramic-on-ceramic revisions between the third- and fourth-generation bearings in total hip arthroplasty from multicentric registry data.

Authors:  Sang-Min Kim; Kee Hyung Rhyu; Jeong Joon Yoo; Seung-Jae Lim; Je Hyun Yoo; Suc Hyun Kweon; Kyung-Jae Lee; Seung-Beom Han
Journal:  Sci Rep       Date:  2021-03-10       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.