Purpose: To evaluate the surface adaptation and maximal biting force of CAD-CAM milled mandibular overdenture (CAD-CAM MOD) compared to conventional compression mold mandibular overdenture (CC MOD). Materials andEntities:
Year: 2022 PMID: 35756959 PMCID: PMC9225844 DOI: 10.1155/2022/8220233
Source DB: PubMed Journal: Int J Dent ISSN: 1687-8728
Figure 1Subjects' selection, treatment procedures, and subjects' evaluation.
Figure 2The processing caps and metal housings were inserted on the implant abutments.
Figure 3The virtual master cast (a) and virtual trial denture (b).
Figure 4Denture base was fabricated from gingival-coloured prepolymerized PMMA blocks (a). The denture teeth were milled from tooth-colored prepolymerized PMMA blocks (b).
Figure 5(a) Fitting surface of CAD-CAM milled mandibular overdentures with picked up attachments. (b) Fitting surface of conventional, compressed mold technique, constructed mandibular overdentures with picked up attachments.
Figure 6Patient exerts a maximum biting force on the bite force transducer.
Descriptive analysis of measured surface deviations between scanned master casts and scanned overdenture bases fabricated by conventional and CAD/CAM milled techniques.
| Positive average values | Negative average values | |||||
|---|---|---|---|---|---|---|
| CC MOD | CAD-CAM MOD | t value ( | CC MOD | CAD-CAM MOD | t value ( | |
| M | 0.099 | 0.034 | 20.77 (0.0001) | −0.081 | −0.055 | 10.22 (0.0001) |
| ±SD | 0.01 | 0.003 | 0.009 | 0.004 | ||
Statistically significant difference. M, mean; SD, standard deviation; CC MOD, conventional compression mold overdenture; CAD-CAM MOD:CAD-CAM mandibular overdenture; (-) average, negative average values; (+) average, positive average values.
Descriptive analysis of maximum biting force (MBF) values andP values of conventional PMMA and CAD/CAM PMMA implant overdenture prostheses along the various follow-up periods.
| Time of measurement | Processing technique (denture type) | |||
|---|---|---|---|---|
| CC MOD | CAD-CAM MOD | t value |
| |
| M ± SD | M ± SD | |||
| 3 months | 166 ± 4.19 | 208 ± 3.17 | 30.96 | (0.0001) |
| 6 months | 170 ± 4.30 | 225 ± 3.45 | 31.54 | (0.0001) |
| t value | 2.16 | 11.47 | ||
|
| (0.05) | (0.0001) | ||
Statistically significant difference. M,mean; SD, standard deviation; CC MOD, conventional compression mold overdenture CAD-CAM MOD:CAD-CAM mandibular overdenture.