Literature DB >> 29896904

A Comparison of the Flexural and Impact Strengths and Flexural Modulus of CAD/CAM and Conventional Heat-Cured Polymethyl Methacrylate (PMMA).

Ziad N Al-Dwairi1, Kawkab Y Tahboub1, Nadim Z Baba2, Charles J Goodacre2.   

Abstract

PURPOSE: The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology to the field of removable prosthodontics has recently made it possible to fabricate complete dentures of prepolymerized polymethyl methacrylate (PMMA) blocks, which are claimed to be of better mechanical properties; however, no published reports that have evaluated mechanical properties of CAD/CAM PMMA. The purpose of this study was to compare flexural strength, impact strength, and flexural modulus of two brands of CAD/CAM PMMA and a conventional heat-cured PMMA.
MATERIALS AND METHODS: 45 rectangular specimens (65 mm × 10 mm × 3 mm) were fabricated (15 CAD/CAM AvaDent PMMA specimens from AvaDent, 15 CAD/CAM Tizian PMMA specimens from Shütz Dental, 15 conventional Meliodent PMMA specimens from Heraeus Kulzer) and stored in distilled water at (37  ± 1°C) for 7 days. Specimens (N = 15) in each group were subjected to the three-point bending test and impact strength test, employing the Charpy configuration on unnotched specimens. The morphology of the fractured specimens was studied under a scanning electron microscope (SEM). Statistical analysis was performed using one-way ANOVA and Tukey pairwise multiple comparisons with 95% confidence interval.
RESULTS: The Schütz Dental specimens showed the highest mean flexural strength (130.67 MPa) and impact strength (29.56 kg/m2 ). The highest mean flexural modulus was recorded in the AvaDent group (2519.6 MPa). The conventional heat-cured group showed the lowest mean flexural strength (93.33 MPa), impact strength (14.756 kg/m2 ), and flexural modulus (2117.2 MPa). Differences in means of flexural properties between AvaDent and Schütz Dental specimens were not statistically significant (p > 0.05).
CONCLUSIONS: As CAD/CAM PMMA specimens exhibited improved flexural strength, flexural modulus, and impact strength in comparison to the conventional heat-cured groups, CAD/CAM dentures are expected to be more durable. Different brands of CAD/CAM PMMA may have inherent variations in mechanical properties.
© 2018 by the American College of Prosthodontists.

Entities:  

Keywords:  CAD/CAM; flexural strength; impact strength

Year:  2018        PMID: 29896904     DOI: 10.1111/jopr.12926

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  9 in total

1.  Comparative analysis of leaching residual monomer and biological effects of four types of conventional and CAD/CAM dental polymers: an in vitro study.

Authors:  Xia Wei; Yu Pan; Mingjun Wang; Yinghui Wang; Honglei Lin; Lei Jiang; Donghong Lin; Hui Cheng
Journal:  Clin Oral Investig       Date:  2022-01-27       Impact factor: 3.573

2.  Flexural strength and impact strength of heat-cured acrylic and 3D printed denture base resins- A comparative in vitro study.

Authors:  Mayank Chhabra; M Nanditha Kumar; K N RaghavendraSwamy; H M Thippeswamy
Journal:  J Oral Biol Craniofac Res       Date:  2021-10-01

3.  In vitro study of surface properties and microbial adhesion of various dental polymers fabricated by different manufacturing techniques after thermocycling.

Authors:  Xia Wei; Linjuan Gao; Kun Wu; Yu Pan; Lei Jiang; Honglei Lin; Yinghui Wang; Hui Cheng
Journal:  Clin Oral Investig       Date:  2022-08-17       Impact factor: 3.606

4.  Tissue Surface Adaptation and Clinical Performance of CAD-CAM Milled versus Conventional Implant-Assisted Mandibular Overdenture.

Authors:  Noha H El-Shaheed; Hanadi A Lamfon; Rabab I Salama; Amira Mohammed Gomaa Faramawy; Aisha Zakaria Hashem Mostafa
Journal:  Int J Dent       Date:  2022-06-16

5.  Effect of Candida albicans Suspension on the Mechanical Properties of Denture Base Acrylic Resin.

Authors:  Grzegorz Chladek; Michał Nowak; Wojciech Pakieła; Anna Mertas
Journal:  Materials (Basel)       Date:  2022-05-27       Impact factor: 3.748

6.  Microbial Adhesion to Dental Polymers for Conventional, Computer-Aided Subtractive and Additive Manufacturing: A Comparative In Vitro Study.

Authors:  Sergey Arutyunov; Levon Kirakosyan; Lubov Dubova; Yaser Kharakh; Nikolay Malginov; Gadzhi Akhmedov; Viktor Tsarev
Journal:  J Funct Biomater       Date:  2022-04-11

Review 7.  Flexural Strength of CAD/CAM Denture Base Materials: Systematic Review and Meta-analysis of In-vitro Studies.

Authors:  Reem Abualsaud; Mohammed M Gad
Journal:  J Int Soc Prev Community Dent       Date:  2022-04-08

8.  Comparison of Mechanical Properties of PMMA Disks for Digitally Designed Dentures.

Authors:  Tamaki Hada; Manabu Kanazawa; Maiko Iwaki; Awutsadaporn Katheng; Shunsuke Minakuchi
Journal:  Polymers (Basel)       Date:  2021-05-26       Impact factor: 4.329

9.  Effect of Antibacterial Silver-Releasing Filler on the Physicochemical Properties of Poly(Methyl Methacrylate) Denture Base Material.

Authors:  Grzegorz Chladek; Katarzyna Pakieła; Wojciech Pakieła; Jarosław Żmudzki; Marcin Adamiak; Cezary Krawczyk
Journal:  Materials (Basel)       Date:  2019-12-11       Impact factor: 3.623

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.