Literature DB >> 27112416

Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques.

Brian J Goodacre1, Charles J Goodacre2, Nadim Z Baba3, Mathew T Kattadiyil4.   

Abstract

STATEMENT OF PROBLEM: Currently no data comparing the denture base adaptation of CAD-CAM and conventional denture processing techniques have been reported.
PURPOSE: The purpose of this in vitro study was to compare the denture base adaptation of pack and press, pour, injection, and CAD-CAM techniques for fabricating dentures to determine which process produces the most accurate and reproducible adaptation.
MATERIAL AND METHODS: A definitive cast was duplicated to create 40 gypsum casts that were laser scanned before any fabrication procedures were initiated. A master denture was made using the CAD-CAM process and was then used to create a putty mold for the fabrication of 30 standardized wax festooned dentures, 10 for each of the conventional processing techniques (pack and press, pour, injection). Scan files from 10 casts were sent to Global Dental Science, LLC for fabrication of the CAD-CAM test specimens. After specimens for each of the 4 techniques had been fabricated, they were hydrated for 24 hours and the intaglio surface laser scanned. The scan file of each denture was superimposed on the scan file of the corresponding preprocessing cast using surface matching software. Measurements were made at 60 locations, providing evaluation of fit discrepancies at the following areas: apex of the denture border, 6 mm from the denture border, crest of the ridge, palate, and posterior palatal seal. The use of median and interquartile range was used to assess accuracy and reproducibility. The Levine and Kruskal-Wallis analysis of variance was used to evaluate differences between processing techniques at the 5 specified locations (α=.05).
RESULTS: The ranking of results based on median and interquartile range determined that the accuracy and reproducibility of the CAD-CAM technique was more consistently localized around zero at 3 of the 5 locations. Therefore, the CAD-CAM technique showed the best combination of accuracy and reproducibility among the tested fabrication techniques. The pack and press technique was more accurate at 2 of the 5 locations; however, its interquartile range (reproducibility) was the greatest of the 4 tested processing techniques. The pour technique was the most reproducible at 2 of the 5 locations; however, its accuracy was the lowest of the tested techniques.
CONCLUSIONS: The CAD-CAM fabrication process was the most accurate and reproducible denture fabrication technique when compared with pack and press, pour, and injection denture base processing techniques.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27112416     DOI: 10.1016/j.prosdent.2016.02.017

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  25 in total

1.  CAD/CAM milled removable complete dentures: an in vitro evaluation of trueness.

Authors:  Murali Srinivasan; Yoann Cantin; Albert Mehl; Harald Gjengedal; Frauke Müller; Martin Schimmel
Journal:  Clin Oral Investig       Date:  2016-11-08       Impact factor: 3.573

2.  CAD/CAM produces dentures with improved fit.

Authors:  Otto Steinmassl; Herbert Dumfahrt; Ingrid Grunert; Patricia-Anca Steinmassl
Journal:  Clin Oral Investig       Date:  2018-02-22       Impact factor: 3.573

Review 3.  Mechanical Properties of the Modified Denture Base Materials and Polymerization Methods: A Systematic Review.

Authors:  Aftab Ahmed Khan; Muhammad Amber Fareed; Abdulkarim Hussain Alshehri; Alhanoof Aldegheishem; Rasha Alharthi; Selma A Saadaldin; Muhammad Sohail Zafar
Journal:  Int J Mol Sci       Date:  2022-05-20       Impact factor: 6.208

4.  Tissue Surface Adaptation and Clinical Performance of CAD-CAM Milled versus Conventional Implant-Assisted Mandibular Overdenture.

Authors:  Noha H El-Shaheed; Hanadi A Lamfon; Rabab I Salama; Amira Mohammed Gomaa Faramawy; Aisha Zakaria Hashem Mostafa
Journal:  Int J Dent       Date:  2022-06-16

Review 5.  Physical and Mechanical Properties of 3D-Printed Provisional Crowns and Fixed Dental Prosthesis Resins Compared to CAD/CAM Milled and Conventional Provisional Resins: A Systematic Review and Meta-Analysis.

Authors:  Saurabh Jain; Mohammed E Sayed; Mallika Shetty; Saeed M Alqahtani; Mohammed Hussain Dafer Al Wadei; Shilpi Gilra Gupta; Ahlam Abdulsalam Ahmed Othman; Abdulkarim Hussain Alshehri; Hatem Alqarni; Abdulaziz Hussain Mobarki; Khalid Motlaq; Haifa F Bakmani; Asma A Zain; Abdullah J Hakami; Moayad F Sheayria
Journal:  Polymers (Basel)       Date:  2022-06-30       Impact factor: 4.967

6.  Comparison of cooling methods on denture base adaptation of rapid heat-cured acrylic using a three-dimensional superimposition technique.

Authors:  Lee Wei May; Jacob John; Lim Ghee Seong; Zubaidah Zanul Abidin; Norliza Ibrahim; Mahmoud Danaee; Noorhayati Raja Mohd
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

7.  Accuracy of Digitally Fabricated Wax Denture Bases and Conventional Completed Complete Dentures.

Authors:  Bogna Stawarczyk; Nina Lümkemann; Marlis Eichberger; Timea Wimmer
Journal:  Dent J (Basel)       Date:  2017-12-19

Review 8.  Clinical Performance of CAD/CAM All-Ceramic Tooth-Supported Fixed Dental Prostheses: A Systematic Review and Meta-Analysis.

Authors:  Babak Saravi; Andreas Vollmer; Maja Hartmann; Gernot Lang; Ralf-Joachim Kohal; Martin Boeker; Sebastian B M Patzelt
Journal:  Materials (Basel)       Date:  2021-05-20       Impact factor: 3.623

9.  Impact of Surface Changes and Microbial Adhesion on Mucosal Surface Finishing of Resin Denture Bases by Shot Blast Polishing Using Viscoelastic Media.

Authors:  Yusuke Yamashita; Yasuhiro Nishi; Mamoru Murakami; Kae Harada; Masahiro Nishimura
Journal:  Materials (Basel)       Date:  2022-03-19       Impact factor: 3.623

10.  Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method.

Authors:  Nadica Janeva; Gordana Kovacevska; Edvard Janev
Journal:  Open Access Maced J Med Sci       Date:  2017-10-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.