Literature DB >> 28891594

Effect of telescopic distal extension removable partial dentures on oral health related quality of life and maximum bite force: A preliminary cross over study.

Moustafa Abdou Elsyad1, Aisha Zakaria Mostafa1.   

Abstract

OBJECTIVES: This cross over study aimed to evaluate the effect of telescopic distal extension removable partial dentures on oral health related quality of life and maximum bite force
MATERIALS AND METHODS: Twenty patients with complete maxillary edentulism and partially edentulous mandibles with anterior teeth only remaining were selected for this cross over study. All patients received complete maxillary dentures and mandibular partial removable dental prosthesis (PRDP, control). After 3 months of adaptation, PRDP was replaced with conventional telescopic partial dentures (TPD) or telescopic partial dentures with cantilevered extensions (TCPD) in a quasi-random method. Oral health related quality of life (OHRQoL) was measured using OHIP-14 questionnaire and Maximum bite force (MBF) was measured using a bite force transducer. Measurements were performed 3 months after using each of the following prostheses; PRDP, TPD, and TCPD.
RESULTS: TCPD showed the OHIP-14 lowest scores (i.e., the highest patient satisfaction with their OHRQoL), followed by TPD, and PRDP showed the highest OHIP-14 scores (i.e., the lowest patient satisfaction with OHRQoL). TCPD showed the highest MBF (70.7 ± 3.71), followed by TPD (57.4 ± 3.43) and the lowest MBF (40.2 ± 2.20) was noted with PRDP.
CONCLUSION: WITHIN The Limitations of This Study, Mandibular Telescopic Distal Extension Removable Partial Dentures with Cantilevered Extensions Were Associated with Improved Oral Health Related Quality of Life and Maximum Bite Force Compared to Telescopic or Conventional PRDP. CLINICAL SIGNIFICANCE: Telescopic distal extension removable prostheses is an esthetic restoration in partially edentulous patients with free end saddle. This article describes the addition of cantilevered extensions of this prosthesis. The results showed that telescopic distal extension removable prostheses with cantilevered extensions were associated with improved oral health related quality of life and maximum bite force compared to telescopic or conventional RPDs.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  OHRQoL; RPD; cantilever; maximum bite force; telescopic

Mesh:

Year:  2017        PMID: 28891594     DOI: 10.1111/jerd.12325

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  3 in total

1.  Tissue Surface Adaptation and Clinical Performance of CAD-CAM Milled versus Conventional Implant-Assisted Mandibular Overdenture.

Authors:  Noha H El-Shaheed; Hanadi A Lamfon; Rabab I Salama; Amira Mohammed Gomaa Faramawy; Aisha Zakaria Hashem Mostafa
Journal:  Int J Dent       Date:  2022-06-16

2.  Bite Force Evaluation in Complete Denture Wearer with Different Denture Base Materials: A Randomized Controlled Clinical Trial.

Authors:  Mostafa I Fayad; Hussam Hakem T Alruwaili; Muhammad Sartaj Khan; Muhammad Nadeem Baig
Journal:  J Int Soc Prev Community Dent       Date:  2018-10-08

Review 3.  Telescopic Denture.

Authors:  Mohammad Ayham Hakkoum; Ghassan Wazir
Journal:  Open Dent J       Date:  2018-03-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.