Literature DB >> 3571306

Kinematic rotating-hinge total knee arthroplasty.

J A Rand, E Y Chao, R N Stauffer.   

Abstract

The first fifty kinematic rotating-hinge total knee arthroplasties that were done at the Mayo Clinic were reviewed. The indication for use of this prosthesis was either ligamentous instability or loss of bone, or both. At a mean length of follow-up of fifty months (range, twenty-nine to seventy-nine months), the clinical results of thirty-eight knees in thirty-six patients were evaluated. Fifteen of the thirty-eight knees had had a primary arthroplasty and twenty-three had had a revision arthroplasty using the kinematic rotating-hinge prosthesis. Using the knee-rating score of The Hospital for Special Surgery, there were fourteen excellent, twelve good, five fair, and five poor results. For two knees there was inadequate information to calculate a knee-rating score. Lucent lines that were more than one millimeter in width were seen with 25 per cent of the femoral and 50 per cent of the tibial components. Progression of lucent lines was observed in thirteen knees, and five knees showed probable radiographic loosening. The high incidence of complications was distressing, with a 16 per cent rate of sepsis, a 22 per cent rate of patellar instability, and a 6 per cent rate of breakage of the implant. In our opinion, this implant should be used only in knees in which there is functional absence of a collateral ligament that cannot be managed by soft-tissue reconstruction.

Entities:  

Mesh:

Year:  1987        PMID: 3571306

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  16 in total

1.  Custom-made rotating hinge total knee replacement in a patient with congenital tibial deficiency avoids the need for amputation.

Authors:  A McGrath; M D Sewell; G Datta; G W Blunn; T W R Briggs; S R Cannon
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-02-15       Impact factor: 4.342

2.  Durable infection control and function with the PROSTALAC spacer in two-stage revision for infected knee arthroplasty.

Authors:  Christopher R Gooding; Bassam A Masri; Clive P Duncan; Nelson V Greidanus; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

3.  Case report: Failure of rotating-hinge total knee prosthesis by disengagement of the hinge-post extension.

Authors:  Debdut Biswas; Bryan Haughom; Robert E Mayle; Craig J Della Valle
Journal:  Clin Orthop Relat Res       Date:  2012-12-11       Impact factor: 4.176

Review 4.  Failure rate of a rotating hinge knee design due to yoke fracture of the hinged tibial insert: a retrospective data analysis and review of the literature.

Authors:  Joerg Friesenbichler; Ran Schwarzkopf; Patrick Sadoghi; Scott E Marwin; Mathias Glehr; Werner Maurer-Ertl; Andreas Leithner
Journal:  Int Orthop       Date:  2011-12-28       Impact factor: 3.075

5.  Primary total knee arthroplasty using rotating-hinge prosthesis in severely affected knees.

Authors:  Jae-Hyuk Yang; Jung-Ro Yoon; Chi-Hun Oh; Taik-Sun Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-20       Impact factor: 4.342

6.  Hinged total knee arthroplasty in the presence of ligamentous deficiency.

Authors:  Daniel Hernández-Vaquero; Manuel A Sandoval-García
Journal:  Clin Orthop Relat Res       Date:  2010-05       Impact factor: 4.176

7.  Distal femoral replacement in nontumor cases with severe bone loss and instability.

Authors:  Keith R Berend; Adolph V Lombardi
Journal:  Clin Orthop Relat Res       Date:  2008-06-04       Impact factor: 4.176

8.  Revision knee arthroplasty with a rotating-hinge design in elderly patients with instability following total knee arthroplasty.

Authors:  E Carlos Rodríguez-Merchán; Primitivo Gómez-Cardero; Ángel Martínez-Lloreda
Journal:  J Clin Orthop Trauma       Date:  2014-11-20

Review 9.  Rotating hinge prosthesis for complex revision total knee arthroplasty: A review of the literature.

Authors:  Shalen Kouk; Parthiv A Rathod; Aditya V Maheshwari; Ajit J Deshmukh
Journal:  J Clin Orthop Trauma       Date:  2017-12-05

10.  Finn/Orthopaedic Salvage System Distal Femoral Rotating-Hinge Megaprostheses in Oncologic Patients: Long-Term Complications, Reoperations, and Amputations.

Authors:  Koichi Ogura; Mohamed A Yakoub; Patrick J Boland; John H Healey
Journal:  J Bone Joint Surg Am       Date:  2021-04-21       Impact factor: 5.284

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.