| Literature DB >> 35696132 |
Shengshu Sun1, Zhanglin Liu1, Yuan Wu1, Xiaowen Sun1,2, Shaozhen Zhao1, Yue Huang1.
Abstract
Purpose: The purpose of this study was to explore the characteristics of pupil offset in young Asian adults with myopia.Entities:
Mesh:
Year: 2022 PMID: 35696132 PMCID: PMC9202332 DOI: 10.1167/tvst.11.6.13
Source DB: PubMed Journal: Transl Vis Sci Technol ISSN: 2164-2591 Impact factor: 3.048
Figure 1.(A) Schematic sketch of pupil center (PC) and corneal vertex (CV), (B) schematic sketch of angle Kappa; red dot A: ideal position of PC, blue dot B: actual position of PC, (C), (D) X and Y components of pupil offset, PC, and CV measured by Pentacam.
Comparisons of Baseline Characteristics Between the Mild-Moderate and High Myopia Groups (Mean ± SD).
| Group | Mild-Moderate | High |
|
|
|---|---|---|---|---|
| Cases/eyes | 300/600 | 300/600 | ||
| Gender (male/female, n/n) | 145/155 | 136/164 | 0.542 | 0.462 |
| Dominant eye (right/left, n/n) | 192/108 | 186/114 | 0.257 | 0.612 |
| Age/years | 22.2 ± 4.8 | 22.9 ± 4.9 | −1.803 | 0.072 |
Comparisons of UCVA, SEQ, Magnitude of Pupil Offset, and its X and Y Components Between the Mild-Moderate Myopia Group and the High Myopia Group (Mean ± SD)
| Variations | M ± SD | β Value | SE | 95% Wald CI | Wald Chi-Square |
|
|---|---|---|---|---|---|---|
| (intercept) | (LogMAR) | 1.354 | 0.0209 | 1.313−1.395 | 4190.37 | 0 |
| UCVA of mild-moderate group | 0.86 ± 0.36 | −0.395 | 0.0253 | −0.444−0.345 | 244.357 | 0.001 |
| UCVA of high group | 1.31 ± 0.28 | 0 | ||||
| (intercept) | (D) | −7.734 | 0.0744 | −7.88 −7.588 | 10816.453 | 0 |
| SEQ of mild-moderate group | −3.28 ± 1.29 | 3.837 | 0.0877 | 3.665 − 4.008 | 1915.68 | 0.001 |
| SEQ of high group | −7.44 ± 0.96 | 0 | ||||
| (intercept) | (mm) | 0.166 | 0.0059 | 0.155 − 0.178 | 782.582 | 0 |
| Pupil offset of mild-moderate group | 0.15 ± 0.08 | −0.011 | 0.005 | −0.021 −0.002 | 5.197 | 0.023 |
| Pupil offset of high group | 0.18 ± 0.09 | 0 | ||||
| (intercept) | (mm) | 0.094 | 0.0055 | 0.084 − 0.105 | 291.168 | 0 |
| X component of mild-moderate group | 0.10 ± 0.07 | −0.005 | 0.0044 | −0.014 − 0.004 | 1.366 | 0.243 |
| X component of high group | 0.11 ± 0.08 | 0 | ||||
| (intercept) | (mm) | 0.123 | 0.0053 | 0.113 − 0.134 | 544.669 | 0 |
| Y component of mild-moderate group | 0.10 ± 0.07 | −0.011 | 0.0046 | −0.02 −0.002 | 5.722 | 0.017 |
| Y component of high group | 0.12 ± 0.08 | 0 |
Set to 0 due to redundancy of this parameter.
Significant difference, P < 0.05 (The following are the same)
Abbreviations: SE, standard error; CI, confidence interval; LogMAR, logarithm of the minimum angle of resolution; D, diopter.
Figure 2.Pupil offset magnitude of mild-moderate and high myopia group.
Figure 3.Linear correlation analysis between the magnitude of (A) pupil offset, (B) X-component, (C) Y-component and SEQ.
Figure 4.Scatter plots of pupil offset direction of (A) the right eyes and (B) the left eyes in the mild-moderate myopia group. Scatter plots of pupil offset direction of (C) the right eyes and (D) the left eyes in the high myopia group. The blue dots represent the PC of each eye. The red ovals represent the standard deviation ellipses. The black dots represent the vector means. Abbreviations: T, temporal; N, nasal.
Multiple Linear Regression Analysis (Stepwise) of Pupil Offset and its X and Y Components With Partial Ocular Parameters and Age
| Pupil Offset | X-component | Y-component | |||||
|---|---|---|---|---|---|---|---|
| Parameters | Coefficient |
| Coefficient | Coefficient | VIF | ||
| Scotopic pupil diameter | −0.01 | 0.135 | −0.003 | 0.563 | 0.001 | 0.844 | 1.000 |
| CCT | 0.001 | 0.01* | 0.001 | 0.501 | 0.001 | 0.432 | 1.000 |
| IOP | −0.004 | 0.001* | 0.001 | 0.676 | 0.001 | 0.699 | 1.002 |
| Mean corneal curvature | −0.004 | 0.038* | 0.001 | 0.600 | −0.001 | 0.629 | 1.007 |
| Age | 0.001 | 0.560 | 0.001 | 0.682 | −0.001 | 0.175 | 1.000 |
Abbreviations: VIF, variance inflation factor; CCT, central corneal thickness; IOP, intraocular pressure.