Literature DB >> 33432995

Distribution of Pupil Offset and Angle Kappa in a Refractive Surgery Preoperative Population of 750 Myopic, Emmetropic, and Hyperopic Eyes.

Dan Z Reinstein, Timothy J Archer, Elizabeth L Rowe, Marine Gobbe, Ryan S Vida.   

Abstract

PURPOSE: To report the distribution of pupil offset and angle kappa in 750 myopic, emmetropic, and hyperopic eyes presenting for refractive surgery.
METHODS: A retrospective study included 750 consecutive eyes screened for corneal refractive surgery between January 2006 and February 2013. The eyes were divided into three equal groups based on manifest refraction spherical equivalent (SEQ): emmetropic group between -0.25 and +0.50 diopters (D) and cylinder up to 1.00 D, myopic group greater than -0.50 D, and hyperopic group greater than +0.50 D. Angle kappa was measured with the Orbscan II software (Bausch & Lomb, Inc) and pupil offset defined as the distance at the corneal plane between the corneal vertex and the pupil center. Correlations with SEQ, cylinder, scotopic pupil diameter, average keratometry, and age were performed.
RESULTS: All results are reported for myopic, emmetropic, and hyperopic groups, respectively. Mean SEQ was -4.84 ± 2.89 D (range: -0.88 to -14.00 D), +0.21 ± 0.23 D (range: -0.25 to +0.50 D), and +2.44 ± 1.58 D (range: +0.63 to +7.75 D). Mean pupil offset magnitude was 0.27 ± 0.14 mm (range: 0.00 to 0.68 mm), 0.34 ± 0.14 mm (range: 0.02 to 0.78 mm), and 0.39 ± 0.13 mm (range: 0.07 to 0.75 mm). Mean pupil offset X-component was -0.18 ± 0.18, -0.28 ± 0.16, and -0.34 ± 0.15 mm (temporally displaced from the corneal vertex). Mean pupil offset Y-component was 0.06 ± 0.15, 0.03 ± 0.16, and 0.01 ± 0.16 mm (superiorly displaced from the corneal vertex). Multivariate linear regression for pupil offset magnitude found statistically significant variables were SEQ, cylinder, scotopic pupil diameter, and average keratometry. For pupil offset X-component, significant variables were SEQ, cylinder, and scotopic pupil diameter. For pupil offset Y-component, significant variables were SEQ and scotopic pupil diameter. Mean angle kappa was 5.28 ± 1.49°, 6.14 ± 1.44°, and 5.77 ± 1.29°.
CONCLUSIONS: Contrary to common belief, a pupil offset is present in the vast majority of eyes regardless of refractive error, with the mean temporal offset of at least 0.18 mm. Confirming previous studies, the largest pupil offset was found in the hyperopic group. However, there was also a wide range of pupil offset in myopic and emmetropic eyes. Correlations with SEQ and keratometry support the theory that pupil offset is also correlated with axial length. [J Refract Surg. 2021;37(1):49-58.]. Copyright 2021, SLACK Incorporated.

Entities:  

Year:  2021        PMID: 33432995     DOI: 10.3928/1081597X-20201109-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  1 in total

1.  Characteristics of Pupil Offset in Young Asian Adults With Mild-Moderate and High Myopia.

Authors:  Shengshu Sun; Zhanglin Liu; Yuan Wu; Xiaowen Sun; Shaozhen Zhao; Yue Huang
Journal:  Transl Vis Sci Technol       Date:  2022-06-01       Impact factor: 3.048

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.