Literature DB >> 31262484

Analysis of excimer laser treatment outcomes and corresponding angle κ in hyperopic astigmatism.

Andreas Frings1, Vasyl Druchkiv2, Lumi Pose3, Stephan J Linke4, Johannes Steinberg4, Toam Katz5.   

Abstract

PURPOSE: To investigate the prevalence of preoperative, intraoperative, and postoperative angle κ in hyperopic eyes and its effect on the refractive outcomes of excimer laser vision correction.
SETTING: University Hospital Hamburg and Care Vision Refractive Centers, Germany.
DESIGN: Retrospective multicenter study.
METHODS: Hyperopic patients after laser in situ keratomileusis and before retreatment because of hyperopic regression were included. Three treatment groups were defined based on the magnitude of preoperative angle κ defined as low (<0.25 mm), moderate (0.25 to 0.50 mm), or high (>0.50 mm).
RESULTS: The study analyzed 170 hyperopic eyes of 112 patients (mean age 29.8 years ± 10.04 [SD], range 21 to 62 years). The preoperative angle κ was low, moderate, or high in 23, 49, and 98 cases, respectively. In eyes with a preoperative angle κ of 0.25 mm or more, changes in the x-axes and y-axes of angle κ and its magnitude were statistically significant (P < .05) between preoperative and intraoperative measurements. In these eyes, intraoperative angle κ (offset) was statistically significantly smaller (P < .05), and Purkinje images were statistically significantly more caudal (P < .001). Treatment predictability was independent from using preoperative or intraoperative angle κ, and there were no statistically significant differences in efficacy or safety.
CONCLUSIONS: A preoperative magnitude of angle κ as high as 0.50 mm or higher was present in more than 50% of regressed hyperopic eyes. Measuring angle κ preoperatively did not reflect its real-time intraoperative magnitude. Using the preoperatively larger angle κ as an intraoperative offset might result in a too nasally centered ablation that causes topographic and optical drawbacks; therefore, centering the ablation based on the intraoperative measured offset is recommended.
Copyright © 2019 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2019        PMID: 31262484     DOI: 10.1016/j.jcrs.2019.01.030

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  3 in total

1.  Characteristics of Pupil Offset in Young Asian Adults With Mild-Moderate and High Myopia.

Authors:  Shengshu Sun; Zhanglin Liu; Yuan Wu; Xiaowen Sun; Shaozhen Zhao; Yue Huang
Journal:  Transl Vis Sci Technol       Date:  2022-06-01       Impact factor: 3.048

Review 2.  Recurring themes during cataract assessment and surgery.

Authors:  Shruti Chandra; Sobha Sivaprasad; Paul G Ursell; Khayam Naderi; David O'Brart; Amar Alwitry; Mayank A Nanavaty
Journal:  Eye (Lond)       Date:  2021-04-29       Impact factor: 4.456

3.  Treatment of High Astigmatism with WaveLight Allegretto Eye-Q Excimer Laser Platform.

Authors:  Alma Biscevic; Maja Bohac; Melisa Ahmedbegovic Pjano; Senad Grisevic; Sudi Patel; Ajla Pidro
Journal:  Acta Inform Med       Date:  2019-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.