| Literature DB >> 35683995 |
Caren Biddulph1, Mark Holmes1, Anna Kuballa1, Roger J Carter2, Judith Maher1.
Abstract
The assessment of body composition during lactation is an important indicator of maternal nutritional status, which is central to the overall health of the mother and child. The lactating woman's nutritional status potentially impacts on breastmilk composition and the process of lactation itself. The purpose of this scoping review was to synthesize comparative studies that sought to validate various body composition assessment techniques for use in lactating women in the postpartum period. Using the PRISMA-ScR guidelines, a comprehensive, systematic literature search was conducted using Scopus, Web of Science, and PubMed. Eight comparative studies were included in the review, with data from 320 postpartum women. The design methodologies varied substantially across studies, and included a range of simple techniques to advanced multi-compartment models for assessing body composition. The validity and reliability of measurement tools must be considered alongside issues of safety, practicality, and appropriateness to guide the research design when applied to lactating women.Entities:
Keywords: anthropometry; breastfeeding; lactation; maternal body composition; maternal nutrition
Mesh:
Year: 2022 PMID: 35683995 PMCID: PMC9182963 DOI: 10.3390/nu14112197
Source DB: PubMed Journal: Nutrients ISSN: 2072-6643 Impact factor: 6.706
Figure 1Preferred Reporting Items for Scoping Reviews and Meta-Analyses (PRISMA) flowchart describing study selection process.
Body composition assessment techniques used in the included studies.
| Reference | Body Composition (BC) Assessment Methods (Maternal) |
|---|---|
| Butte, N.F., et al. (1997) [ | Two-component (TBW, UWW, SF, TBK, DXA/TOBEC), three-component (TBW and UWW -Fuller 3, Siri 3), four-component models (TBW, UWW, and BMC-Fuller 4). TBW by deuterium oxide dilution. |
| Ellegård, L., et al. (2016) [ | BW, height, BIS, MFBIA, DXA, and TBW via DLW. |
| Hopkinson, J.M., et al. (1997) [ | TBW, TBK, body density, BMC by deuterium dilution, whole-body potassium counting, hydrodensitometry, and DXA (postpartum only). |
| Lof, M., et al. (2004) [ | BIS (supine), reference isotope, and bromide dilution (only 2H2O was given at the postpartum measurement). |
| Medoua, G.N., et al. (2011) [ | Anthropometry (triceps, biceps, subscapular, suprailiac sites), BIA (supine), reference method: deuterium oxide dilution. |
| Papathakis, P.C., et al. (2005) [ | TBW using BIS and 2H2O to measure FFM and FM. Anthropometric measurements: BW, height, BMI, MUAC and four skinfold thicknesses (triceps, biceps, subscapular, and suprailiac). |
| Sohlström, A., et al. (1997) [ | TBW by isotope dilution, MRI (30 transaxial images over the complete body except the head, hands, and feet), biceps, triceps, subscapular, and suprailiac SKF thicknesses. |
| Wong, W.W., et al. (1989) [ | Anthropometry (triceps, biceps, and subscapular SKF) and deuterium dilution (HM, urine, saliva, breath). |
BF, body fat; FFM, fat-free mass; FM, fat mass; BC, body composition; TBW, total body water; UWW, underwater weighing; SF/SKF, skinfold; TBK, total body potassium (whole body potassium scanning); DXA/DEXA, dual X-ray absorptiometry; TOBEC, total body electrical conductivity; BIA, bioimpedance analysis; BIS, bioimpedance spectroscopy; MF-BIA, multifrequency bioimpedance analysis; DLW, doubly-labelled water; MRI, magnetic resonance imaging.
Comparison studies assessing the validity of body composition assessment methods in lactating women.
| Reference | Study Objective(s) | Study Population | Study Design | 2C Body Composition (BC) Assessment Methods (Maternal) | 3C Body Composition (BC) Assessment Methods (Maternal) | 4C or Organ/Tissue Models for Body Composition (BC) Assessment Methods (Maternal) | Timing of BC Measurements | Method Comparison | Comparative Validity, Reliability, and/or Appropriateness | Relevant Findings | Strengths | Limitations |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Butte, N.F., et al. (1997) [ | To compare postpartum changes in BC by two-, three-, and four-compartment models and test for an effect of pregnancy or lactation on hydration, density, or potassium content of FFM. | N = 35 healthy postpartum women, lactating and nonlactating women (29 Caucasian, 2 African American, 4 Hispanic), USA. | FFM and FM estimated by nine BC models at three time points (3, 6 and 12 months postpartum) were compared using repeated measures ANOVA, as were changes in FFM and FM at two time intervals (3–6 months and 6–12 months postpartum). | TBW, UWW, SF, TBK, DXA/TOBEC. | TBW and UWW –Fuller 3, Siri 3. | TBW, UWW and BMC –Fuller 4; TBW by deuterium dilution. | 3, 6 and 12 months postpartum. | Noted systematic differences among BC models in FFM and FM measures, but not in terms of longitudinal changes in FFM and FM. | No effect of pregnancy/lactation on the postpartum composition of FFM by 3 months, so two-component models are acceptable for use in postpartum women. | Pregnancy-induced changes in the hydration, density and potassium content of FFM were not evident by 3 months postpartum. Changes in FFM and FM did not differ significantly between models. The rank order from the highest to lowest estimate of FFM was TOBEC, TBW, Fuller 3, Siri 3, Fuller 4, UWW, SF, TBK, and DXA. | Numerous models and methods used: systematic differences noted between the models. | Not all lactating: breastfeeding prevalence was 27/35, 22/35, and 9/35 at 3, 6 and 12 months, respectively. |
| Ellegård, L., et al. (2016) [ | To validate BIS and MFBIA with the reference methods DXA and DLW, and to assess BC in overweight/obese women postpartum. | Repeated measurements of BC (FM, FFM, skeletal muscle mass, and TBW) using reference methods and simple methodology (both cross-sectional and longitudinal). | BW, height, BIS, MFBIA, and TBW via DLW (isotope dilution of both D2O and H2O). | DXA | N/A | 3 (baseline), 6 (12-week intervention) and 15 months postpartum (1-year follow-up). | Both BIS and, even more so, MFBIA underestimated FM and overestimated FFM and TBW. | Most accurate and precise TBW compared with DLW was obtained using 73% of FFM as assessed by DXA. | BIS underestimates FM, but accurately estimates muscle mass and changes in BC; MFBIA underestimates FM and overestimates TBW. Impedance devices underestimate FM in overweight and obese women. | Used accepted reference methods. Three repeated measures. | Systematic bias introduced via body positioning (impedance increases in supine over time). Bioimpedance devices used are too imprecise for individual evaluation. | |
| Hopkinson, J.M., et al. (1997) [ | To evaluate 2C and 3C models in the early-postpartum period. | Used a four-component model as a criterion for evaluating two- and three-component models. | TBW, hydrodensitometry. | DXA (postpartum only). | TBW, body density, BMC by deuterium dilution, whole-body potassium count (TBK). | Twice, at 36 ± 1 week gestation and 15 ± 2 days postpartum. | FM by TBK may differ by up to 6 kg from 4C model at 2 weeks postpartum. Use of standard 2C models to estimate FM results in significant error both at 2 weeks postpartum. | 3C model compared favorably with 4C Fuller et al.’s model for estimation of mean and individual FM and change in FM. | At 2 wk. postpartum, FFM hydration and density had not returned to nonpregnant values, and differed between lactating (higher) and nonlactating women ( | Used a four-component model as a criterion for evaluating two- and three-component models. | Black women have around 7–8% more bone mineral and 4% more non-osseous mineral than white women, but this sample did not provide sufficient power to address the influence of ethnicity on intermethod differences. | |
| Lof, M., et al. | To evaluate BIS measurements of body water distribution in healthy women before, during, and after pregnancy. | Methodological study comparing BIS measures of ECW, ICW, and TBW, with reference methods, over the reproductive cycle. | BIS (supine), reference isotope and bromide dilution (only 2H2O was given at the postpartum measurement). | N/A | N/A | Before pregnancy, 14, and 32 weeks gestation, 2 weeks postpartum. | Average estimates of ICW by BIS were in good agreement with the corresponding reference data (not individual). | BIS (2C) may be useful for estimating average ICW, as well as changes in ICW, in groups of women during reproduction. | Postpartum average ICW, ECW, and TBW, estimated by BIS, were in agreement with reference data. | Longitudinal measures with reference methods. | Wrist–ankle measurements of resistance in BIS, assumes that the body consist of five cylinders. | |
| Medoua, G.N., et al. (2011) [ | To compare BC estimates using deuterium dilution, MF-BIA, and SKF techniques in lactating women. | Comparison of the results of BC from the deuterium dilution technique with more convenient MFBIA and skinfold thickness methods. | Anthropometry (triceps, biceps, subscapular, suprailiac sites), BIA (supine), reference method: deuterium oxide dilution. | N/A | N/A | 2.63 ± 1.31 months postpartum. | Inappropriate to use anthropometry or BIA equations to predict body composition in a population different from the population in which these equations were developed. | BC was affected ( | Anthropometric and BIA-based predictive equations overestimated BF by 2.7 to 11.7 kg; and underestimated TBW and FFM. Higher biases when using Black-specific equations. | Bland and Altman tests to determine bias and limits of agreement between values predicted by equations and measured by deuterium oxide dilution. | Small sample, no control group of healthy non-lactating women, use of the hydration factor 0.73. | |
| Papathakis, P.C., et al. (2005) [ | To determine the validity of BIS and anthropometric measurements to measure BC compared to the stable isotope dilution method. To describe the BC of HIV-infected lactating women. | Compared the ability of BIS and anthropometry to determine TBW with isotope dilution (2H2O) to determine FM and FFM in HIV+ and HIV- breastfeeding women. | TBW using BIS and 2H2O to measure FFM and FM. Anthropometric measurements: BW, ht, BMI, MUAC, and four skinfold thicknesses (triceps, biceps, subscapular, and suprailiac). | N/A | N/A | Once, at 10 weeks postpartum. | Measurements determined by BIS correlated with 2H2O. BMI, MUAC, and skinfold-thickness measurements correlated strongly with FM measured by 2H2O; FFM only in HIV- mothers. | BIS comparable to reference 2H2O method. BMI and MUAC are useful in predicting FM, but are not valid measures of FFM in HIV+ mothers. | TBW by BIS was 5–6% greater than 2H2O method but FM or FFM did not differ significantly by method. Difference deemed acceptable by the authors. | Used the stable isotope deuterium oxide (2H2O) is a reference technique for measuring TBW. | Only assessed HIV-infected women without severe immune suppression. | |
| Sohlström, A., et al. (1997) [ | To compare changes in total BF assessed by MRI, body water dilution, and skinfold thickness in postpartum women. | Changes in total BF during the human reproductive cycle as assessed by MRI, body water dilution, and SKF thickness: a comparison of methods. | TBW by isotope dilution; biceps, triceps, subscapular, and suprailiac SKF thicknesses. | N/A | MRI (30 transaxial images over the complete body except the head, hands, and feet). | Before pregnancy and at 5–10 days and 2, 6, and 12 months postpartum. | Estimates of changes in BF by isotope dilution may be unreliable and invalid, as the degree of hydration of FFM may change over the course of the postpartum period in women. | Risk for bias when changes in TBF during reproduction are estimated by SKF-thickness technique and isotope dilution. | Changes in the degree of hydration of FFM may occur after delivery. SKF method tended to overestimate fat retention compared with MRI, and underestimate the amount of mobilized fat. | Results of BF from the MRI technique are more valid than changes estimated with use of body water or SKF techniques. | SKF technique: during both pregnancy and lactation, a redistribution of subcutaneous adipose tissue may occur. | |
| Wong, W.W., et al. (1989) [ | To compare estimations of BF, FFM, and TBW of lactating women by anthropometric and deuterium dilution methods. | Comparison of anthropometric equations and deuterium dilution method in calculating postpartum BC. | Anthropometry (triceps, biceps and subscapular SKF) and deuterium dilution (HM, urine, saliva, breath). | N/A | N/A | Once, at 3.4 ± 1.3 months postpartum. | Deuterium dilution method involves certain assumptions and errors, but is more direct and precise. | Difficulty in obtaining accurate and reproducible skinfold thickness measurements in the suprailiac regions of post-partum women, so excluded. | No significant differences in mean BF, FFM, or TBW between anthropometry and deuterium dilution; however, wide 95% CI, so not applicable to individuals. | Technical aspects of the deuterium dilution method also investigated. | Deuterium dilution overestimates TBW to the degree that deuterium exchanges with non-aqueous hydrogens. |
BF, body fat; FFM, fat-free mass; FM, fat mass; BC, body composition; TBW, total body water; UWW, underwater weighing; SF/SKF, skinfold; TBK, total body potassium (whole-body potassium scanning); DXA/DEXA, dual X-ray absorptiometry; TOBEC, total body electrical conductivity; BIA, bioimpedance analysis; BIS, bioimpedance spectroscopy; MF-BIA, multifrequency bioimpedance analysis; DLW, doubly-labelled water; MRI, magnetic resonance imaging.