| Literature DB >> 35621609 |
Louis Hardan1, Davide Mancino2,3, Rim Bourgi1, Alejandra Alvarado-Orozco4, Laura Emma Rodríguez-Vilchis4, Abigailt Flores-Ledesma5, Carlos Enrique Cuevas-Suárez6, Monika Lukomska-Szymanska7, Ammar Eid8, Maya-Line Danhache9, Maryline Minoux3,10, Youssef Haïkel2,3, Naji Kharouf2,3.
Abstract
Since the adhesion of resin composites to calcium silicate-based cement is considered challenging. Therefore, the best adhesion strategy should be indicated. This review aimed to assess the effect of different adhesive systems on the bond strength of resin composite to calcium silicate-based cement through a systematic review and meta-analysis. The subsequent PICOS framework used was: population, calcium silicate-based cement; intervention, use of self-etch adhesive systems; control, use of total-etch adhesive systems; outcome, bond strength; study design, in vitro studies. The literature search was conducted independently by two reviewers up to 18 February 2021. Electronic databases (PubMed, ISI Web of Science, SciELO, Scopus, and Embase) were searched for applicable articles. In vitro manuscripts studying the effect of adhesive systems on the bond strength of calcium silicate-based cement were considered. The meta-analyses were performed using Review Manager Software version 5.3.5 (The Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark). Bond strength comparisons were made considering the type of calcium silicate-based cement (Mineral Trioxide Aggregate (MTA), Biodentine™, or TheraCal LC®). A p-value < 0.05 was considered statistically significant. A total of 7321 studies were retrieved in databases searched. After full-text evaluation, 37 eligible papers were assessed for qualitative analysis, leaving a total of 22 papers for the quantitative analysis. According to the meta-analysis, the bond strength values of resin composite materials to MTA and TheraCal LC® cement were favored when a total-etch adhesive system was used (p ≤ 0.02). On the other hand, the meta-analysis of the bond strength of resin-based materials to Biodentine™ calcium silicate-based cement was similar between both approaches (p = 0.12). The in vitro evidence suggests that the bond strength of resin-based materials to both MTA and TheraCal LC® cement was preferred by using the total-etch adhesive strategy. However, when bonding to Biodentine™, the use of self-etch or total-etch strategies displayed promising results. Given the lack of evidence related to the chemical interaction of self-etch adhesive materials with the bioceramics, if self-etch adhesives are used for bonding resin-based restorations to calcium silicate-based cement, a pretreatment with phosphoric acid could be recommended.Entities:
Keywords: adhesive systems; bond strength; calcium silicate-based cement; composite
Year: 2022 PMID: 35621609 PMCID: PMC9141246 DOI: 10.3390/gels8050311
Source DB: PubMed Journal: Gels ISSN: 2310-2861
Figure 1Search flowchart according to the PRISMA Statement.
Demographic data.
| Author | Bioceramic Used as Substrate | Bioceramic Setting Conditions | Bonding Systems Used | Composite Resin | Storing Conditions | Bond Strength Test | Secondary Outcome |
|---|---|---|---|---|---|---|---|
| Ajami, | CEM (Bionique Dent; Tehran, Iran). NAMTA (produced by dr. Lotfi in Tabriz Dental Faculty, Tabriz, Iran). | 37 °C with 100% humidity relative for 24 h. | Total-etch adhesive (Adper TM Single Bond; 3M ESPE, St. Paul, MN, USA) | Filtek TM Z250 (3M ESPE Dental Products, St. Paul, MN, USA) | 100% relative | Shear bond strength (SBS) | Fracture analysis |
| Ajami, | MTA | 37 °C in 100% humidity for 2.45 h and 3 days. | Total-etch adhesive (Adper Single Bond II™; 3M ESPE, St Paul, MN, USA) | Valux Plus composite resin (3M ESPE, St Paul, MN, USA) | 37 °C in 100% humidity for | SBS | - |
| Altunsoy, | MTA (Angelus, Londrina, PR, Brazil) | 100% humidity at 37 °C for 72 h. | Self-adhesive restorative (Vertise Flow | X-tra base | 100% relative humidity at 37 °C for 24 h. | SBS | Fracture surface analysis |
| Alzraikat, | ProRoot | 100% humidity and 37 °C for 48 h | Total-etch adhesive (AdperTM Single bond 2; | Filtek™ Z250 | 100% relative humidity at 37 °C for 24 h. | SBS | Fracture surface analysis |
| Atabek, | WMTA | 37 °C with 100% humidity for 4, 24, 48, 72, and 96 h. | Total-etch adhesive (One-Step Plus and All-Bond 3; Bisco Inc, Schaumburg, IL, USA) | Composite Aelite (Bisco Inc, Schaumburg, IL, USA) | 100% relative humidity | SBS | Fracture Analysis |
| Bayrak, | White MTA | 37 °C with 100% humidity for 48 h. | Total-etch adhesive (Prime & Bond NT; Caulk/Dentsply International Inc., Milford, DE, USA) | Dyract AP | 100% | SBS | Fracture analysis |
| Cantekin, | Biodentine™ (Septodont, Saint Maur des Fosses, France) | 37 °C in 100% humidity for 15 min | Total-etch adhesive | Aelite All Purpose Body (Bisco Inc, | 37 °C in | SBS | - |
| Cantekin, | TheraCal (Bisco, Inc., Schamburg, IL, USA). | light-cured with an LED | Total-etch adhesive (One-Step Plus; Bisco Inc, Schamburg, | AELITE (Bisco, Inc. Schamburg, IL, USA) | 100% relative humidity at 37 °C for 24 h. | SBS | Fracture surface analysis |
| Carretero, | Biodentine™ (Septodont, Saint Maur des Fosses, France) | 37 °C and 100% humidity for 12 min and 24 h. | Total-etch adhesive (Optibond FL; Kerr Corp, Orange, CA, | Grandio® | 37 °C in 100% humidity for | SBS | Fracture surface analysis |
| Cengiz, | TheraCal | Light cured for 20 s | Universal Adhesive (Single bond Universal, 3M ESPE; St Paul, MN, USA) | Filtek Bulk | 100% relative humidity at 37 °C for 24 h. | SBS | Fracture surface analysis |
| Colak, | Biodentine™ (Septodont, Saint Maur des | 37 °C in 100% humidity for 9 min, and 48 h. | Self-etch adhesive (Clearfil S3 Bond; Kuraray Medical, Osaka, Japan. Adper Prompt L-Pop; 3M/ESPE, St. Paul, MN, | Filtek Z250, (3M/ESPE, St. Paul, MN, USA) | 37 °C in 100% humidity for | SBS | Fracture surface analysis |
| Doozaneh, | RootMTA (Tabriz, Iran) | 37 °C in 100% humidity for 72 h. | Total-etch adhesive (OptiBond all-in-one; Kerr Dental, Orange CA, USA) | Vertise Flow (Kerr, Orange, CA, USA) | 37 °C in 100% humidity for | SBS | Fracture surface analysis |
| Elmi, | CEM cement (Yektazist Dandan, Tehran, Iran) | 37 °C and 100% humidity for 48 h. | Total-etch adhesive (Single bond 2;3M, St. Paul, MN, USA) | Z250 (3M ESPE, St. Paul, MN, USA) | 37 °C in 100% humidity for | SBS | Fracture surface analysis |
| Ha, | GC Fuji IX GP Capsule | 37 °C and 100% humidity for 12 min, 72 h and 2 weeks. | Total-etch adhesive (Optibond FL; Kerr Dental, Orange, USA) | G-aenial Universal Flow (GC CORPORATION, | 37 °C in 100% humidity for 90 min. | SBS | Fracture surface analysis |
| Hursh, | White ProRoot mineral trioxide aggregate (MTA) (Dentsply Tulsa Dental, Tulsa, OK) | 37 °C | Self-etch adhesive (Clearfil SE Bond; Kuraray America, Inc., New | Clearfil DC Core Plus (Kuraray America, Inc.) | 37 °C in 100% humidity for 7 days. | SBS | Fracture surface analysis |
| Karadas, | TheraCal LC® (Bisco; Schaumburg, IL, USA) | Light-curing | Total-etch adhesive (Adper Scotchbond | Filtek Z250 (3M ESPE; Saint Paul, MN, USA) | 37 °C in 100% humidity for | SBS | Fracture surface analysis |
| Krawczyk-Stuss, | Biodentine™ (Septodent, Saint-Maur-des-Fosses Cedex, France) | 12 min in 0.9% NaCl. | Total-etch adhesive (Adper Single Bond; 3M ESPE, | Filtek Z250 (3M ESPE, St. Paul, MN, | - | SBS | - |
| Murat, | Biodentine™ (Septodent, Saint-Maur-des-Fosses Cedex, France) | 37 °C with 100% humidity during for 12 min, 24 h and 2 weeks | Universal Adhesive (Single Bond Universal; 3M Espe, St. Paul, MN, USA) | Tetric EvoCeram Bulk Fill (Ivoclar Vivadent, Schaan, Lichtenstein) | 37 °C in 100% humidity for | SBS | Fracture surface analysis |
| Mustafa, 2020 | Biodentine™ (Septodent, Saint-Maur-des-Fosses Cedex, France) | 37 °C in artificial | Total-etch adhesive (AdperTM Single; 3M Oral Care, St. Paul, MN, USA) | Tetric EvoCeram (Ivoclar | 37 °C in artificial | SBS | Fracture surface analysis |
| Nagi, | MTA Angelus (Angelus, Londrina, PR, Brazil) | 37 °C with 100% humidity during for 72 h. | Universal adhesive (Single bond universal; 3M ESPE. St. Paul, MN, USA) | Filtek Z250 | 37 °C in 100% humidity for | SBS | Failure analysis |
| Neelakantan, | WMTA | Immediate, 45 min and 24 h. | Total-etch adhesive | Filtek Z350 (3M ESPE, St. Paul, MN, USA.) | 100% relative | SBS | Fracture analysis |
| Nekoofar, | Biodentine™ (Septodont, Saint Maur des Fosses, France) | 37 °C and 100% humidity for 12 min, one week, and one month. | Total-etch adhesive | Filtek Z350 XT (3M/ESPE, St. Paul, MN, USA) | 37 °C in 100% humidity for | SBS | - |
| Odabas, | Biodentine™ | 37 °C with 100% humidity for 12 min and 24 h. | Total-etch adhesive | Clearfil | 100% relative humidity at 37 °C for 24 h. | SBS | Fracture Analysis |
| Palma, | ProRoot MTA (Dentsply Tulsa Dental) | 37 °C in 100% humidity for | Universal Adhesive | SDR (Dentsply | 37 °C in 100% humidity for | SBS | Fracture surface analysis |
| Palma, | Biodentine™ (Septodont, | 37 °C and 100% relative humidity for 12 min and 7 days. | Self-etch adhesive (Clearfil SE Bond; Kuraray Medical, | SDR Bulk fill flowable composite | 37 °C with 100% humidity for 48 h. | SBS | Fracture surface analysis |
| Priya, | White MTA (ANGELUS) | 37 °C with 100% | Total-etch adhesive (Adper Single Bond 2; 3M ESPE, St.Paul, MN, USA) | Filtek Z250 Z250 (3M ESPE; Saint Paul, MN, USA) | 37 °C with 100% | SBS | - |
| Raina, | Dycal (Dentsply Caulk, Milford, DE, USA) | 37 °C and 100% relative humidity for 72 h. | Self-etch adhesive (OptiBond; Kerr Dental, Orange, USA) | SDR (Dentsply DeTrey GmbH, Konstanz, | 37 °C and 100% relative humidity for 24 h. | SBS | Scanning electron microscopy (SEM). |
| Samimi, | ProRoot MTA (Dentsply, Tulsa, OK, USA) | 37 °C in 100% humidity for | Total-etch adhesive (OptiBond Solo Plus; Kerr, Karlsruhe, Germany) | Point 4 (3M ESPE, St. Louis, MN, USA) | 37 °C in 100% humidity for | SBS | SEM analysis |
| Savadi, 2014 | Calcium Enriched Mixture (BioniqueDent Tehran, Iran). | 37 °C with 100% humidity for 50 min. | Total-etch adhesive | Gradia Direct (GC Corporation, Tokyo, Japan) | 100% relative humidity at 37 °C for 24 h. | SBS | - |
| Schmidt, |
| 3 min | Self-etch adhesive | Ionoseal (VOCO, Cuxhaven, Germany) | 37 °C in 100% humidity for | SBS | Fracture surface analysis |
| Shin, | ProRoot MTA (WMTA) (Dentsply, | 100% humidity at 37 °C for a week. | Total-etch adhesive (Scotchbond Multipurpose; 3M ESPE, St Paul, MN, USA. Single Bond 2; 3M ESPE, St Paul, MN, USA.). | Filtek Flow (3M ESPE, St Paul, MN, USA) | 100% relative humidity at 37 °C for 24 h. | SBS | Scanning Electron Microscopic Analysis |
| Sulwinska, | Pro Root MTA | Directly after | Universal adhesive (Single Bond Universal; 3M ESPE, St. Paul, MN, USA) | Filtek Ultimate (3M ESPE, St. Paul, MN, USA) | 37 °C with > 95% relative humidity. | SBS | Fracture surface analysis |
| Tulumbaci, | Pro Root MTA | 37 °C in 100% humidity for | Total-etch adhesive (Prime and Bond NT; Dentsply, Tulsa, OK, USA ) | Filtek Z250 (3M ESPE, USA) | 37 °C in 100% humidity for | SBS | Fracture surface analysis |
| Tunc, | WMTA (Dentsply, Tulsa Dental) | 37 °C with 100% humidity for 48 h. | Total-etch adhesive (3M/ESPE, St | Filtrek Z250 (3M/ESPE, St Paul, MN, USA) | 100% relative humidity | SBS | - |
| Yelamali, 2016 | White MTA (Angelus, Londrina, Brazil) | 37 °C with 100% humidity in an incubator for 24 h. | Total-etch adhesive (Adper Single Bond 2; 3M/ESPE, St. Paul, MN, USA) | Filtek Z350 (3M ESPE, St Paul, MN, USA) | 100% relative humidity at | SBS | - |
| Yesilyurt, | BioAggregate | 100% humidity at 37 °C for 24 and 72 h. | Self-etch adhesive | Ultimate Flow (UF; Kerr, Orange, | 100% relative humidity at 37 °C for 24 h. | SBS | Fracture surface analysis |
| Zarean, | Mineral trioxide aggregate (ProRoot® MTA; | 37 °C | Total-etch adhesive (Solobond M; VOCO GmbH, Cuxhaven, Germany) | Grandio Flow composite resin (VOCO GmbH, Cuxhaven, Germany) | 37 °C and 100% relative humidity for 24 h. | SBS | Fracture surface analysis |
Figure 2Findings of the meta-analysis of the bond strength of resin-based materials to MTA calcium silicate-based cement. Bond strength was higher when a total-etch adhesive was used (p < 0.01).
Figure 3Findings of the meta-analysis of the bond strength of resin-based materials to Biodentine™ calcium silicate-based cement. Bond strength was similar between both strategies (p = 0.12).
Figure 4Findings of the meta-analysis of the bond strength of resin-based materials to TheraCal LC® calcium silicate-based cement. Bond strength was higher for the total-etch technique (p = 0.02).
Risk of bias assessment. (Red Code = High risk; Black code = Medium risk).
| Author | Sample Randomization | Single Operator | Blinded Operator | Sample Dimensions | Sample Size Calculation | Control Group (without Pretreatment) | Manufacturer Instructions | Risk of Bias |
|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
| Ajami, | YES | NO | NO | YES | YES | NO | YES | Medium |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Atabek, | YES | NO | NO | YES | NO | YES | YES | Medium |
|
|
|
|
|
|
|
|
|
|
| Buldur, | YES | NO | NO | YES | NO | NO | YES | Medium |
| Cantekin, | YES | YES | NO | YES | NO | NO | YES | Medium |
| Cantekin, | YES | NO | NO | YES | NO | NO | YES | Medium |
|
|
|
|
|
|
|
|
|
|
| Cengiz, | YES | NO | NO | YES | NO | NO | YES | Medium |
| Colak, | YES | YES | NO | YES | NO | NO | YES | Medium |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Krawczyk-Stuss, | NO | YES | NO | YES | NO | YES | YES | Medium |
| Mustafa, | YES | NO | NO | YES | YES | NO | YES | Medium |
|
|
|
|
|
|
|
|
|
|
| Neelakantan, | YES | YES | YES | YES | NO | NO | YES | Medium |
| Nekoofar, | YES | NO | NO | YES | NO | YES | YES | Medium |
| Odabas, | YES | NO | NO | YES | NO | YES | YES | Medium |
| Palma, | YES | NO | NO | YES | NO | NO | YES | Medium |
| Palma, | YES | NO | NO | YES | YES | NO | YES | Medium |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Samimi, | NO | NO | NO | YES | NO | YES | YES | Medium |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Shin, | YES | NO | NO | YES | NO | NO | YES | Medium |
| Sulwinska, | NO | YES | NO | YES | NO | YES | YES | Medium |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Yelamali, 2016 | YES | NO | NO | YES | NO | NO | YES | Medium |
| Yesilyurt, | NO | NO | NO | YES | NO | YES | YES | Medium |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Keywords used in search strategy.
| #1 | Calcium silicate-based cements, calcium-silicate cement, tri-calcium based cements, mineral trioxide aggregate (MTA), ProRoot MTA, MTA-Angelus, Biodentine, TheraCal LC, silicate cement, tricalcium silicatecalcium based |
| #2 | Universal bonding agent, composite, restorative materials, resin composite, universal adhesive, flowable composite, adhesive systems, total-etch adhesive, self-etch adhesive |
| #3 | Bond, bonding, shear bond strength, bonding performance, bonding effectiveness, bonding properties, microtensile bond strength, microshear bond strength, shear bond strength test |