A GPU-accelerated framework for rapid estimation of scanner-specific scatter in CT for virtual imaging trials.

Shobhit Sharma1,2, Ehsan Abadi1,3, Anuj Kapadia1,2,3, W Paul Segars1,3,4, Ehsan Samei1,2,3,4,5.   

Abstract

Virtual imaging trials (VITs), defined as the process of conducting clinical imaging trials using computer simulations, offer a time- and cost-effective alternative to traditional imaging trials for CT. The clinical potential of VITs hinges on the realism of simulations modeling the image acquisition process, where the accurate scanner-specific simulation of scatter in a time-feasible manner poses a particular challenge. To meet this need, this study proposes, develops, and validates a rapid scatter estimation framework, based on GPU-accelerated Monte Carlo (MC) simulations and denoising methods, for estimating scatter in single source, dual-source, and photon-counting CT. A CT simulator was developed to incorporate parametric models for an anti-scatter grid and a curved energy integrating detector with an energy-dependent response. The scatter estimates from the simulator were validated using physical measurements acquired on a clinical CT system using the standard single-blocker method. The MC simulator was further extended to incorporate a pre-validated model for a PCD and an additional source-detector pair to model cross scatter in dual-source configurations. To estimate scatter with desirable levels of statistical noise using a manageable computational load, two denoising methods using a (1) convolutional neural network and an (2) optimized Gaussian filter were further deployed. The viability of this framework for clinical VITs was assessed by integrating it with a scanner-specific ray-tracer program to simulate images for an image quality (Mercury) and an anthropomorphic phantom (XCAT). The simulated scatter-to-primary ratios agreed with physical measurements within 4.4% ± 10.8% across all projection angles and kVs. The differences of ∼121 HU between images with and without scatter, signifying the importance of scatter for simulating clinical images. The denoising methods preserved the magnitudes and trends observed in the reference scatter distributions, with an averaged rRMSE value of 0.91 and 0.97 for the two methods, respectively. The execution time of ∼30 s for simulating scatter in a single projection with a desirable level of statistical noise indicates a major improvement in performance, making our tool an eligible candidate for conducting extensive VITs spanning multiple patients and scan protocols.
© 2021 Institute of Physics and Engineering in Medicine.

Entities:  

Keywords:  Monte Carlo; computed tomography; dual source; photon counting; scatter; virtual imaging trials

Year:  2021        PMID: 33652421     DOI: 10.1088/1361-6560/abeb32

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  A scanner-specific framework for simulating CT images with tube current modulation.

Authors:  Giavanna Jadick; Ehsan Abadi; Brian Harrawood; Shobhit Sharma; W Paul Segars; Ehsan Samei
Journal:  Phys Med Biol       Date:  2021-09-13       Impact factor: 3.609

2.  Development and Clinical Applications of a Virtual Imaging Framework for Optimizing Photon-counting CT.

Authors:  Ehsan Abadi; Cindy McCabe; Brian Harrawood; Saman Sotoudeh-Paima; W Paul Segars; Ehsan Samei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.