Literature DB >> 20798436

Photographic measurement of the inclination of the acetabular component in total hip replacement using the posterior approach.

J C Hill1, D P Gibson, R Pagoti, D E Beverland.   

Abstract

The angle of inclination of the acetabular component in total hip replacement is a recognised contributing factor in dislocation and early wear. During non-navigated surgery, insertion of the acetabular component has traditionally been performed at an angle of 45 degrees relative to the sagittal plane as judged by the surgeon's eye, the operative inclination. Typically, the method used to assess inclination is the measurement made on the postoperative anteroposterior radiograph, the radiological inclination. The aim of this study was to measure the intra-operative angle of inclination of the acetabular component on 60 consecutive patients in the lateral decubitus position when using a posterior approach during total hip replacement. This was achieved by taking intra-operative photographs of the acetabular inserter, representing the acetabular axis, and a horizontal reference. The results were compared with the post-operative radiological inclination. The mean post-operative radiological inclination was 13 degrees greater than the photographed operative inclination, which was unexpectedly high. It appears that in the lateral decubitus position with a posterior approach, the uppermost hemipelvis adducts, thus reducing the apparent operative inclination. Surgeons using the posterior approach in lateral decubitus need to aim for a lower operative inclination than when operating with the patient supine in order to achieve an acceptable radiological inclination.

Entities:  

Mesh:

Year:  2010        PMID: 20798436     DOI: 10.1302/0301-620X.92B9.24476

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  7 in total

1.  Validation of use of transverse acetabular ligament and mechanical angle guide device to orient the acetabular cup.

Authors:  Archit Agarwal; Inder Pawar; Sandeep Singh; Deepti Randev; Hem Chandra Sati
Journal:  J Clin Orthop Trauma       Date:  2020-08-06

2.  Smartphone Application Helps Improve the Accuracy of Cup Placement by Young, Less-Experienced Surgeons during Primary Total Hip Arthroplasty.

Authors:  Ahmed A Khalifa; Mohammad K Abdelnasser; Ahmed M Ahmed; Gautam M Shetty; Ahmed M Abdelaal
Journal:  Arch Bone Jt Surg       Date:  2022-03

3.  Current Concepts in Acetabular Positioning in Total Hip Arthroplasty.

Authors:  Deepu Bhaskar; Asim Rajpura; Tim Board
Journal:  Indian J Orthop       Date:  2017 Jul-Aug       Impact factor: 1.251

4.  Positioning of the acetabular component in cemented prostheses - radiographic calculation.

Authors:  Pedro José Labronici; Ramon Louro Motta; Bruno Bandeira Esteves; José Sergio Franco; Rolix Hoffmann; Luiz Aurélio Costa Ferreira; Marcos Giordano; Sergio Delmonte Alves
Journal:  Rev Bras Ortop       Date:  2013-06-11

Review 5.  Can the use of an inclinometer improve acetabular cup inclination in total hip arthroplasty? A review of the literature.

Authors:  Bernard H van Duren; Joseph M Royeca; Conor M Cunningham; Jonathan N Lamb; Chris J Brew; Hemant Pandit
Journal:  Hip Int       Date:  2020-08-04       Impact factor: 2.135

6.  Mechanical and Anatomical Alignment Guide Techniques Are Superior to Freehand in Achieving Target Orientation of an Acetabular Component.

Authors:  Robert Bruce-Brand; Paul Magill; Christopher O'Neill; Paul Karayiannis; Janet Hill; David Beverland
Journal:  Arthroplast Today       Date:  2021-10-08

Review 7.  Cup placement in primary total hip arthroplasty: how to get it right without navigation or robotics.

Authors:  Geert Meermans; George Grammatopoulos; Moritz Innmann; David Beverland
Journal:  EFORT Open Rev       Date:  2022-05-31
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.