Comparison of Motion Artifacts on CT Images Obtained in the Ultrafast Scan Mode and Conventional Scan Mode for Unconscious Patients in the Emergency Department.

Tomko Takayanagi1,2, Shigeru Suzuki1, Yoshiaki Katada1, Takuya Ishikawa1, Rika Fukui1, Yuzo Yamamoto1, Osamu Abe2.   

Abstract

OBJECTIVE. The purpose of this study was to investigate whether, in the evaluation of unconscious patients in the emergency department, a new-generation CT scanner that acquires images in ultrafast scan mode (large coverage, fast rotation, high helical pitch) would reduce motion artifacts on whole-body CT images in comparison with those on images obtained with a conventional CT scanner. MATERIALS AND METHODS. Images of a total of 60 unconscious patients presenting to the emergency department were evaluated retrospectively. Of the 60 patients, 30 underwent CT with a new-generation scanner that acquires images in the ultrafast mode, and 30 underwent CT with a conventional scanner. Two radiologists independently evaluated motion artifacts in the aorta, lung, diaphragm, liver, and kidneys. The motion artifacts were graded in severity on a 4-point scale. A value of p < 0.05 was considered to indicate a statistically significant difference. RESULTS. Interobserver agreement on motion artifact ratings was good (κ = 0.80-0.93). Images obtained with the new-generation CT scanner showed a significant reduction in motion artifacts in the aortic root (p = 0.0003), lower lungs (p = 0.011), diaphragm (p = 0.0047), liver (p = 0.0026), and kidneys (p = 0.019). However, there were no significant differences between the two groups with respect to motion artifacts of the aortic arch, thoracic descending aorta, abdominal aorta, and upper lungs. CONCLUSION. CT images obtained in the ultrafast scan mode in the evaluation of unconscious patients had a significant reduction in motion artifacts. The ultrafast technique is expected to be useful for diagnostic CT in the emergency department.

Entities:  

Keywords:  CT; emergency radiology; motion artifact; ultrafast scan; whole-body CT

Year:  2019        PMID: 31166767     DOI: 10.2214/AJR.19.21456

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  2 in total

1.  The ultrafast, high-pitch turbo FLASH mode of third-generation dual-source CT: Effect of different pitch and corresponding SFOV on image quality in a phantom study.

Authors:  Yang Zhou; Lei Hu; Silin Du; Rui Jin; Wangjia Li; Fajin Lv; Zhiwei Zhang
Journal:  J Appl Clin Med Phys       Date:  2021-11-09       Impact factor: 2.102

2.  Reduction of Peristalsis-Related Streak Artifacts on the Liver with Dual-Layer Spectral CT.

Authors:  Sergio Grosu; Zhen J Wang; Markus M Obmann; Mark D Sugi; Yuxin Sun; Benjamin M Yeh
Journal:  Diagnostics (Basel)       Date:  2022-03-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.