Manuel Hein1, Philipp Breitbart1, Jan Minners1, Philipp Blanke2, Simon Schoechlin1, Christopher Schlett3, Tobias Krauss3, Martin Soschynski3, Franz-Josef Neumann1, Philipp Ruile1.
Abstract
(1) Background: Early hypo-attenuated leaflet thickening (HALT) is diagnosed by computed tomography angiography (CTA) in approximately 15% of patients undergoing transcatheter aortic valve replacement (TAVR). We sought to investigate the diagnostic performance of CTA for the diagnosis of HALT, focusing on timing data assessment within the cardiac cycle. (2)Entities:
Keywords: TAVI; TAVR; computed tomography; hypo-attenuated leaflet thickening; leaflet thrombosis; post-TAVR-CTA
Year: 2022 PMID: 35407425 PMCID: PMC8999481 DOI: 10.3390/jcm11071817
Source DB: PubMed Journal: J Clin Med ISSN: 2077-0383 Impact factor: 4.241
Baseline characteristics of patients without and with HALT.
| All Patients | Without HALT ( | With HALT ( | |||
|---|---|---|---|---|---|
| Age | 81.5 ± 5.5 | 80.1 ± 5.4 | 82.2 ± 5.5 | 0.185 | |
| Gender | |||||
| Male | 37 (37.0) | 16 (32.0) | 21 (42.0) | 0.400 | |
| Female | 63 (63.0) | 34 (68.0) | 29 (58.0) | ||
| BMI | (kg/m²) | 27.1 ± 4.3 | 27.3 ± 4.7 | 27.0 ± 3.8 | 0.809 |
| Creatinine-Clearance | (mL/min) | 54.7 ± 17.3 | 55.5 ± 18.6 | 53.9 ± 16.1 | 0.648 |
| LV-EF | (%) | 50.0 (8.3) | 51.5(8.1) | 49.1 (8.4) | 0.162 |
| Atrial fibrillation | 31 (31.0) | 20 (40.0) | 11 (22.0) | 0.083 | |
| Mitral regurgitation | None/mild | 76 (76.0) | 37 (74.0) | 39 (78.0) | 0.591 |
| Moderate | 20 (20.0) | 10 (20.0) | 10 (20.0) | ||
| Severe | 4 (4.0) | 3 (6.0) | 1 (2.0) | ||
| Tricuspid regurgitation | None/mild | 90 (90) | 42 (84) | 48 (96) | 0.092 |
| Moderate | 10 (10) | 8(16) | 2(4) | ||
| Heart rate at the time of CT | 54.7 ± 17.3 | 55.8 ± 18.6 | 53.9 ± 16.1 | 0.440 | |
| Tube voltage (kV) | 102.8 ± 9.9 | 103.2 ± 10.2 | 100.0 ± 9.9 | 0.835 | |
| Tube current (mAs) | 307.7 ± 51.1 | 302.0 ± 49.4 | 307.7 ± 52.9 | 0.605 | |
| Effective Dose (mSv) | 9.8 ± 5.1 | 10.2 ± 10.2 | 9.5 ± 5.1 | 0.336 | |
| Prosthesis size | Small (23 mm) | 33 (34.7) | 18 (36.0) | 15 (33.3) | 0.867 |
| Medium (25–27 mm) | 39 (41.1) | 21 (42.0) | 18 (40.0) | ||
| Large (29–31 mm) | 23 (24.2) | 11 (22.0) | 12 (26.7) | ||
| Prosthesis type | S3/XT | 86 (86.0) | 43 (86.0) | 43(86.0) | 1.000 |
| CoreValve/EvoluteR | 14 (14.0) | 7 (14.0) | 7 (14.0) | ||
| PVL at time of CTA (TTE) | None/Trace | 81 (81.0) | 40 (80.0) | 41 (81.0) | 1.000 |
| Mild | 19 (19.0) | 10 (20.0) | 9 (18.0) | ||
| Moderate | 0 | 0 | 0 | ||
| Visual Image Quality | 0 | 1 (1.0) | 1 (2.0) | 0 (0.0) | 0.010 |
| 1 | 10 (10.0) | 6 (12.0) | 4 (8.0) | ||
| 2 | 51 (51.0) | 32 (64.0) | 19 (38.0) | ||
| 3 | 38 (38.0) | 11 (22.0) | 27 (54.0) | ||
HALT: hypo-attenuated leaflet thickening. Values are mean ± SD, median [interquartile range], or n (%). BMI= body mass index. LV-EF: Left ventricular ejection fraction. PVL: Paravalvular leakage. TTE: Transthoracic echocardiogram. mAs: milliampere-second. kV: kilovoltage. Image quality was graded in consensus as follows: 0 = very poor image quality, 1 = poor, 2 = good, 3 = very good.
Comparison of single observer diagnosis of HALT in different phases of the cardiac cycle with full cardiac cycle consensus reading.
| Diastole | Systole | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Observer A | Observer B | Observer A | Observer B | |||||||||
| Mid-Diastole | Entire Diastole | Mid-Diastole | Entire Diastole | Consensus | Consensus | End-Systole | Entire Systole | End-Systole | Entire Systole | Consensus | Consensus Entire Systole | |
| True positive | 38 | 42 | 32 | 42 | 38 | 43 | 36 | 42 | 32 | 38 | 36 | 41 |
| True negative | 46 | 45 | 47 | 47 | 49 | 47 | 47 | 46 | 49 | 47 | 49 | 46 |
| False positive | 4 | 5 | 3 | 3 | 1 | 3 | 3 | 4 | 1 | 3 | 1 | 4 |
| False negative | 12 | 8 | 18 | 8 | 12 | 12 | 14 | 8 | 18 | 12 | 14 | 9 |
| % Accuracy | 0.84 | 0.87 | 0.79 | 0.89 | 0.87 | 0.90 | 0.83 | 0.88 | 0.81 | 0.85 | 0.85 | 0.87 |
| % Sensitivity | 0.76 | 0.84 | 0.64 | 0.84 | 0.80 | 0.87 | 0.72 | 0.84 | 0.64 | 0.76 | 0.78 | 0.84 |
| % Specificity | 0.92 | 0.90 | 0.94 | 0.94 | 0.94 | 0.92 | 0.94 | 0.28 | 0.98 | 0.94 | 0.95 | 0.94 |
| PPV | 0.64 | 0.61 | 0.67 | 0.73 | 0.71 | 0.67 | 0.69 | 0.66 | 0.86 | 0.71 | 0.88 | 0.66 |
| NPV | 0.63 | 0.59 | 0.67 | 0.65 | 0.65 | 0.61 | 0.66 | 0.62 | 0.73 | 0.66 | 0.73 | 0.62 |
| PLR | 9.5 | 8.2 | 10.7 | 14.0 | 13.3 | 10.7 | 12.0 | 10.2 | 32 | 12.7 | 36 | 10.3 |
| NLR | 0.26 | 0.18 | 0.38 | 0.17 | 0.21 | 0.14 | 0.30 | 0.18 | 0.37 | 0.26 | 0.24 | 0.17 |
HALT = hypo-attenuated leaflet thickening, PPV = positive predictive value, NPV = negative predictive value, PLR = positive likelihood ratio, NLR = negative likelihood ratio.
Figure 1Examples of prostheses with Hypoattenuated Leaflet Thickening (HALT). (A) HALT (white arrows) depicted in systole (left) and diastole (right) (B) HALT (black arrows) missed in systole (left), but depicted in diastole (right).
Linear regression of factors influencing image quality.
| Heartrate | Ejection Fraction | Mitral Regurgitation | Tricuspid Regurgitation | |||||
|---|---|---|---|---|---|---|---|---|
| Standardized Beta |
| Standardized Beta |
| Standardized Beta |
| Standardized Beta |
| |
| Mid-diastole | −0.40 | <0.001 | −0.12 | 0.22 | 0.13 | 0.194 | 0.11 | 0.28 |
| entire diastole | −0.32 | 0.002 | −0.10 | 0.32 | 0.14 | 0.164 | 0.075 | 0.47 |
| end-systole | −0.07 | 0.54 | −0.127 | 0.21 | 0.043 | 0.67 | 0.08 | 0.44 |
| entire systole | −0.06 | 0.55 | 0.73 | 0.47 | 0.02 | 0.81 | 0.07 | 0.49 |