Objective: The present study aims to compare the detection rates of different diagnostic methods for primary peripheral lung cancer (PPLC).Entities:
Keywords: CT-guided; clinical research; fiberoptic bronchoscope; methods of sampling; peripheral lung cancer
Year: 2022 PMID: 35371969 PMCID: PMC8968742 DOI: 10.3389/fonc.2021.696239
Source DB: PubMed Journal: Front Oncol ISSN: 2234-943X Impact factor: 6.244
Comparison of different sampling methods for different lesions of different sizes under fiberoptic bronchoscopy.
| Diameter of focus (cm) | n | Brush inspection | Flush | TBLB | Brush inspection +Flush +TBLB | χ2 |
|
|---|---|---|---|---|---|---|---|
| detection rate (%) | detection rate (%) | detection rate (%) | detection rate (%) | ||||
| 0.8 -2 | 38 | 5/38 (13%) | 3/38 (8%) | 6/38 (16%) | 13/38 (34%) | 10.223 | 0.016 |
| 2-5 | 86 | 17/86 (20%) | 15/86 (17%) | 38/86 (44%) | 59/86 (69%) | 63.442 | <0.001 |
| >5 | 62 | 22/62 (35%) | 18/62 (29%) | 44/62 (71%) | 52/62 (84%) | 53.664 | <0.001 |
| Total | 186 | 44/186 (24%) | 36/186 (19%) | 88/186 (47%) | 124/186 (67%) | 113.553 | <0.001 |
There was a statistical difference of P < 0.05. TBLB, transbronchial lung biopsy.
Comparison of joint sampling method under fiberoptic bronchoscopy and CT-PNB sampling method.
| Group | n | Diameter of focus 0.8-2cm | Diameter of focus 2-5cm | Diameter of focus >5cm |
|---|---|---|---|---|
| number of positive cases/cases | number of positive cases/cases | number of positive cases/cases | ||
| Brush inspection +flush +TBLB | 186 | 13/38 (34%) | 59/86 (69%) | 52/62 (84%) |
| CT-PNB | 173 | 47/57 (82%) | 61/65 (94%) | 49/51 (96%) |
| χ2 | 22.808 | 12.457 | 4.393 | |
|
| <0.001 | <0.001 | 0.036 |
There was a statistical difference of P < 0.05. CT, PNB. CT-guided percutaneous lung puncture biopsy; TBLB, transbronchial lung biopsy.
Comparison of clinical features between the two groups.
| Characteristics | Brush inspection +flush +TBLB | CT-PNB | |
|---|---|---|---|
| N = 186 | N = 173 | ||
| Age (years) | |||
| ≤55 | 78 | 67 | |
| >55 | 108 | 106 | |
| Gender | |||
| Male | 115 | 122 | |
| Female | 71 | 51 | |
| Histological type | |||
| Squamous cell | 53 | 46 | |
| carcinoma | |||
| Adenocarcinoma | 94 | 96 | |
| Small cell carcinoma | 39 | 31 | |
| TNM Classification | |||
| I-IIIa | 63 | 70 | |
| IIIb-IV | 84 | 72 |
CT-PNB, CT-guided percutaneous lung puncture biopsy; TBLB, transbronchial lung biopsy.
Figure 1A case of tracheoscopic operation.
Figure 2Two case of CT-guided lung puncture. (A) Lesion diameter of 2-5 cm; (B) Lesion diameter >5cmssssss.
Comparison of different sampling methods for different lesions of different sizes under fiberoptic bronchoscopy.
| Diameter of focus (cm) | n | Brush inspection | Flush | TBLB | χ2 |
|
|---|---|---|---|---|---|---|
| detection rate (%) | detection rate (%) | detection rate (%) | ||||
| 0.8 -2 | 38 | 5/38 (13%) | 3/38 (8%) | 6/38 (16%) | 1.14 | 0.565 |
| 2-5 | 86 | 17/86 (20%) | 15/86 (17%) | 38/86 (44%) | 19.095 | <0.001 |
| >5 | 62 | 22/62 (35%) | 18/62 (29%) | 44/62 (71%) | 25.529 | <0.001 |
| Total | 186 | 44/186 (24%) | 36/186 (19%) | 88/186 (47%) | 40.062 | <0.001 |
There was a statistical difference of P < 0.05. TBLB, taransbronchial lung biopsy.