| Literature DB >> 35324751 |
Alexandra Jităreanu1, Irina Gabriela Cara2, Alexandru Sava3, Ioana Mârțu4, Ioana-Cezara Caba1, Luminița Agoroaei1.
Abstract
The growing popularity of electronic cigarettes has raised several public health concerns, including the risks associated with heavy metals exposure via e-liquids and vapors. The purpose of this study was to determine, using atomic absorption spectrometry, the concentrations of Pb, Ni, Zn, and Co in some commercially available e-liquid samples from Romania immediately after purchase and after storage in clearomizers. Lead and zinc were found in all investigated samples before storage. The initial concentrations of Pb ranged from 0.13 to 0.26 mg L-1, while Zn concentrations were between 0.04 and 0.07 mg L-1. Traces of nickel appeared in all investigated e-liquids before storage but in very small amounts (0.01-0.02 mg L-1). Co was below the detection limits. We investigated the influence of the storage period (1, 3, and 5 days), storage temperature (22 °C and 40 °C), and type of clearomizer. In most cases, the temperature rise and storage period increase were associated with higher concentrations of heavy metals. This confirms that storage conditions can affect metal transfer and suggests that the temperature of storage is another parameter that can influence this phenomenon.Entities:
Keywords: e-liquids; heavy metals; storage
Year: 2022 PMID: 35324751 PMCID: PMC8950552 DOI: 10.3390/toxics10030126
Source DB: PubMed Journal: Toxics ISSN: 2305-6304
Basic composition of EC liquids selected in this study.
| Sample | Nicotine (mg/mL) | PG:VG Ratio ( | Flavor |
|---|---|---|---|
| A | 0 | 50:50 | Dark tobacco |
| B | 6 | 70:30 | Cherry |
| C | 12 | 50:50 | Apple |
| D | 18 | 70:30 | Tobacco |
| E | 18 | 50:50 | Cuban cigar |
Data presented were available on the labels of the products.
Figure 1Anatomy of the clearomizers used in the experiment ((A) clearomizer 1; (B) clearomizer 2).
Calibration results for the determination of heavy metals in e-cigarettes.
| Metal | Wavelength | Linear Range | Detection Limit (mg L−1) | Correlation Coefficient (R2) | RSD |
|---|---|---|---|---|---|
| Pb | 217.00 | 0.1–0.5 | 0.04 | 0.998 | 1.9 |
| Zn | 213.85 | 0.05–0.5 | 0.001 | 0.999 | 2.1 |
| Ni | 232.00 | 0.05–0.5 | 0.01 | 0.999 | 1.7 |
| Co | 240.72 | 0.05–0.5 | 0.005 | 0.997 | 3.4 |
The measurements were done in triplicate; RSD, Relative Standard Deviation of the triplicate measurements.
The average recovery (%) and RSD (%) of spiked samples.
| Metal | E-Liquid Sample | PG/VG Mixture | ||||||
|---|---|---|---|---|---|---|---|---|
| 1.0 mg L−1 | 5.0 mg L−1 | 1.0 mg L−1 | 5.0 mg L−1 | |||||
| Recovery (%) | RSD (%) | Recovery (%) | RSD (%) | Recovery (%) | RSD (%) | Recovery (%) | RSD (%) | |
| Pb | 94.1 | 2.5 | 96.2 | 1.9 | 95.7 | 7.8 | 95.9 | 4.1 |
| Zn | 98.3 | 4.5 | 107.3 | 2.1 | 94.8 | 4.6 | 95.5 | 6.9 |
| Ni | 95.4 | 1.7 | 95.7 | 2.3 | 98.1 | 3.9 | 101.3 | 4.8 |
| Co | 96.4 | 5.5 | 104.2 | 3.4 | 95.7 | 4.2 | 98.1 | 2.4 |
RSD, Relative Standard Deviation of the triplicate measurements; PG, propylene glycol; V, vegetable glycerin.
Heavy metals (Pb, Ni, Zn) concentrations in EC liquids under different conditions.
| Sample | Initial Conc. | Clearomizer 1 | Clearomizer 2 | ||
|---|---|---|---|---|---|
| 22 °C | 40 °C | 22 °C | 40 °C | ||
| Pb | |||||
| A(1) | 0.17 ± 0.02 | 0.28 ± 0.01 | 0.53 ± 0.01 | 0.37 ± 0.02 | 0.81 ± 0.01 |
| A(3) | 0.58 ± 0.03 | 0.84 ± 0.02 | 0.74 ± 0.05 | 0.88 ± 0.09 | |
| A(5) | 0.98 ± 0.04 | 1.84 ± 0.04 | 1.84 ± 0.07 | 1.94 ± 0.07 | |
| B(1) | 0.15 ± 0.03 | 0.47 ± 0.01 | 0.67 ± 0.03 | 0.50 ± 0.06 | 0.86 ± 0.02 |
| B(3) | 0.78 ± 0.02 | 1.15 ± 0.11 | 0.78 ± 0.03 | 1.30 ± 0.06 | |
| B(5) | 2.99 ± 0.15 | 3.22 ± 0.21 | 1.97 ± 0.7 | 1.98 ± 0.8 | |
| C(1) | 0.26 ± 0.06 | 0.58 ± 0.11 | 1.02 ± 0.16 | 0.49 ± 0.08 | 1.12 ± 0.21 |
| C(3) | 0.78 ± 0.16 | 1.45 ± 0.18 | 0.85 ± 0.10 | 1.73 ± 0.36 | |
| C(5) | 0.98 ± 0.20 | 1.86 ± 0.11 | 1.89 ± 0.08 | 2.38 ± 0.31 | |
| D(1) | 0.13 ± 0.01 | 0.20 ± 0.01 | 0.29 ± 0.04 | 0.76 ± 0.14 | 6.63 ± 1.32 |
| D(3) | 0.42 ± 0.03 | 0.90 ± 0.07 | 0.94 ± 0.19 | 8.56 ± 1.78 | |
| D(5) | 0.74 ± 0.04 | 1.77 ± 0.11 | 1.85 ± 0.21 | 10.48 ± 1.91 | |
| E(1) | 0.19 ± 0.01 | 1.20 ± 0.19 | 4.72 ± 0.83 | 1.98 ± 0.73 | 4.48 ± 1.03 |
| E(3) | 2.56 ± 0.53 | 5.36 ± 0.38 | 3.69 ± 1.03 | 7.88 ± 2.11 | |
| E(5) | 2.95 ± 0.74 | 7.27 ± 0.95 | 5.16 ± 1.38 | 9.23 ± 2.18 | |
| Ni | |||||
| A(1) | 0.01 ± 0.01 | 0.11 ± 0.02 | 0.22 ± 0.08 | 0.15 ± 0.01 | 0.25 ± 0.02 |
| A(3) | 0.18 ± 0.01 | 0.31 ± 0.05 | 0.23 ± 0.05 | 0.31 ± 0.06 | |
| A(5) | 0.33 ± 0.05 | 0.46 ± 0.11 | 0.58 ± 0.09 | 2.30 ± 0.29 | |
| B(1) | 0.02 ± 0.01 | 0.09 ± 0.01 | 0.25 ± 0.05 | 1.10 ± 0.11 | 1.02 ± 0.11 |
| B(3) | 0.60 ± 0.09 | 0.89 ± 0.07 | 1.73 ± 0.21 | 1.95 ± 0.18 | |
| B(5) | 1.19 ± 0.12 | 1.59 ± 0.22 | 2.08 ± 0.26 | 2.83 ± 0.13 | |
| C(1) | 0.02 ± 0.01 | 0.03 ± 0.01 | 0.27 ± 0.09 | 0.19 ± 0.03 | 0.15 ± 0.04 |
| C(3) | 0.05 ± 0.01 | 1.02 ± 0.26 | 0.89 ± 0.11 | 0.83 ± 0.09 | |
| C(5) | 0.16 ± 0.03 | 1.61 ± 0.28 | 0.78 ± 0.08 | 0.87 ± 0.17 | |
| D(1) | 0.01 ± 0.01 | 0.18 ± 0.07 | 0.57 ± 0.11 | 0.15 ± 0.06 | 2.56 ± 0.42 |
| D(3) | 0.33 ± 0.1 | 0.66 ± 0.18 | 0.63 ± 0.07 | 3.59 ± 0.38 | |
| D(5) | 0.51 ± 0.11 | 0.87 ± 0.12 | 1.06 ± 0.11 | 4.04 ± 0.96 | |
| E(1) | 0.02 ± 0.01 | 0.18 ± 0.06 | 1.62 ± 0.53 | 1.28 ± 0.52 | 3.60 ± 0.84 |
| E(3) | 0.32 ± 0.09 | 2.45 ± 0.78 | 2.63 ± 0.31 | 4.56 ± 0.91 | |
| E(5) | 0.56 ± 0.15 | 3.96 ± 0.82 | 5.01 ± 0.79 | 8.19 ± 0.78 | |
| Zn | |||||
| A(1) | 0.04 ± 0.01 | 0.17 ± 0.02 | 0.62 ± 0.12 | 0.17 ± 0.01 | 0.31 ± 0.08 |
| A(3) | 0.30 ± 0.09 | 0.79 ± 0.19 | 0.19 ± 0.01 | 0.37 ± 0.11 | |
| A(5) | 0.31 ± 0.07 | 0.85 ± 0.39 | 0.25 ± 0.03 | 0.45 ± 0.18 | |
| B(1) | 0.07 ± 0.01 | 1.36 ± 0.25 | 1.93 ± 0.43 | 0.91 ± 0.09 | 0.51 ± 0.17 |
| B(3) | 4.02 ± 0.72 | 4.95 ± 0.61 | 3.50 ± 0.72 | 2.41 ± 0.77 | |
| B(5) | 5.52 ± 0.73 | 6.98 ± 0.95 | 4.03 ± 0.90 | 3.78 ± 0.85 | |
| C(1) | 0.05 ± 0.01 | 0.78 ± 0.01 | 5.59 ± 0.67 | 0.16 ± 0.08 | 0.20 ± 0.02 |
| C(3) | 1.25 ± 0.82 | 7.14 ± 0.85 | 0.88 ± 0.81 | 0.79 ± 0.14 | |
| C(5) | 4.59 ± 0.91 | 7.84 ± 0.73 | 1.46 ± 0.93 | 1.84 ± 0.20 | |
| D(1) | 0.07 ± 0.01 | 0.69 ± 0.09 | 0.93 ± 0.15 | 1.01 ± 0.12 | 1.54 ± 0.84 |
| D(3) | 2.60 ± 0.55 | 4.33 ± 0.83 | 1.12 ± 0.05 | 4.89 ± 0.66 | |
| D(5) | 3.45 ± 0.86 | 4.56 ± 0.79 | 1.72 ± 0.09 | 5.89 ± 0.90 | |
| E(1) | 0.06 ± 0.01 | 3.35 ± 0.94 | 3.65 ± 0.25 | 2.40 ± 0.38 | 2.53 ± 0.62 |
| E(3) | 7.45 ± 0.92 | 7.52 ± 0.89 | 3.12 ± 0.47 | 5.35 ± 0.88 | |
| E(5) | 8.45 ± 0.85 | 8.20 ± 0.96 | 7.38 ± 0.73 | 8.75 ± 0.97 | |
Data are presented as mean ± SD (standard deviation). Sample code: Sample number (number of storage days in the clearomizer).
Figure 2The influence of storage temperature and of the clearomizer on Pb concentration. Sample code: Sample number (number of storage days in the clearomizer).
The influence of the duration of storage on Pb concentration; p-value for the paired t-test (t-test: Paired Two Sample for Means).
| Storage | I vs. 1 D | I vs. 3 D | I vs. 5 D | 1 D vs. 3 D | 1 D vs. 5 D | 3 D vs. 5 D |
| Clearomizer 1 (22 °C) |
|
|
|
|
| 0.068 |
| Clearomizer 1 (40 °C) | 0.099 | 0.054 |
|
|
|
|
| Clearomizer 2 (22 °C) |
|
|
| 0.055 |
|
|
| Clearomizer 2 (40 °C) |
|
|
|
|
|
|
I, initial; 1 D, storing for 1 day; 3 D, storing for 3 days; 5 D, storing for 5 days. Bold numbers denote the cases in which differences are statistically significant at 95% confidence level. Clearomizer 1, CE4-type clearomizer; Clearomizer 2, T3S-type clearomizer.
Figure 3The influence of storage temperature and of the clearomizer on Ni concentration. Sample code: Sample number (number of storage days in the clearomizer).
The influence of the duration of storage on Ni concentration; p-value for the paired t-test (t-test: Paired Two Sample for Means).
| Storage | I vs. 1 D | I vs. 3 D | I vs. 5 D | 1 D vs. 3 D | 1 D vs. 5 D | 3 D vs. 5 D |
|---|---|---|---|---|---|---|
| Clearomizer 1 (22 °C) |
|
|
| 0.054 |
|
|
| Clearomizer 1 (40 °C) |
|
|
|
|
|
|
| Clearomizer 2 (22 °C) |
|
|
|
|
| 0.096 |
| Clearomizer 2 (40 °C) |
|
|
|
|
|
|
I, initial; 1 D, storing for 1 day; 3 D, storing for 3 days; 5 D, storing for 5 days. Bold numbers denote the cases in which differences are statistically significant at 95% confidence level. Clearomizer 1, CE4-type clearomizer; Clearomizer 2, T3S-type clearomizer.
Figure 4The influence of storage temperature and of the clearomizer on Zn concentration. Sample code: Sample number (number of storage days in the clearomizer).
The influence of the duration of storage on Zn concentration; p-value for the paired t-test (t-test: Paired Two Sample for Means).
| Storage | I vs. 1 D | I vs. 3 D | I vs. 5 D | 1 D vs. 3 D | 1 D vs. 5 D | 3 D vs. 5 D |
|---|---|---|---|---|---|---|
| Clearomizer 1 (22 °C) |
|
|
|
|
|
|
| Clearomizer 1 (40 °C) |
|
|
|
|
|
|
| Clearomizer 2 (22 °C) | 0.064 |
|
| 0.053 |
| 0.070 |
| Clearomizer 2 (40 °C) |
|
|
|
|
| 0.051 |
I, initial;1 D, storing for 1 day; 3 D, storing for 3 days; 5 D, storing for 5 days. Bold numbers denote the cases in which differences are statistically significant at 95% confidence level. Clearomizer 1, CE4-type clearomizer; Clearomizer 2, T3S-type clearomizer.