| Literature DB >> 29679608 |
Eleni Kamilari1, Konstantinos Farsalinos2, Konstantinos Poulas3, Christos G Kontoyannis4, Malvina G Orkoula5.
Abstract
Electronic cigarettes are considered healthier alternatives to conventional cigarettes containing tobacco. They produce vapor through heating of the refill liquids (e-liquids) which consist of propylene glycol, vegetable glycerin, nicotine (in various concentrations), water and flavoring agents. Heavy metals may enter the refill liquid during the production, posing a risk for consumer's health due to their toxicity. The objective of the present study was the development of a methodology for the detection and quantitative analysis of cadmium (Cd), lead (Pb), nickel (Ni), copper (Cu), arsenic (As) and chromium (Cr), employing Total Reflection X-Ray Fluorescence Spectroscopy (TXRF) as an alternative technique to ICP-MS or ICP-OES commonly used for this type of analysis. TXRF was chosen due to its advantages, which include short analysis time, promptness, simultaneous multi-element analysis capability and minimum sample preparation, low purchase and operational cost. The proposed methodology was applied to a large number of electronic cigarette liquids commercially available, as well as their constituents, in order to evaluate their safety. TXRF may be a valuable tool for probing heavy metals in electronic cigarette refill liquids to serve for the protection of human health.Entities:
Keywords: Electronic cigarette; Heavy metals; Refill liquid; Total Reflection X-ray Fluorescence Spectroscopy
Mesh:
Substances:
Year: 2018 PMID: 29679608 DOI: 10.1016/j.fct.2018.04.035
Source DB: PubMed Journal: Food Chem Toxicol ISSN: 0278-6915 Impact factor: 6.023