| Literature DB >> 35321306 |
Anjali Kapoor1, A Rizwan Ali1, Neha Saini1, Kompal Gautam2, Akansha Goyal1, Vasundhara Prakash1.
Abstract
Context: Status of bone-implant interface or osseointegration can be assessed by using resonance frequency analysis (RFA), which measures implant stability. A modified implant surface can significantly enhance osseointegration and reduce healing period. Platelet-rich fibrin (PRF) consists of fibrin mesh with entrapped platelets and leukocytes that release a huge number of growth factors which contribute to wound healing and tissue regeneration. Aims: The present study aims to evaluate the effect of PRF on osseointegration in terms of implant stability. Settings and Design: This was a split-mouth randomized clinical trial. Materials andEntities:
Keywords: Dental implants; implant stability; osseointegration; platelet-rich fibrin; resonance frequency analysis
Year: 2022 PMID: 35321306 PMCID: PMC8936022 DOI: 10.4103/jisp.jisp_74_21
Source DB: PubMed Journal: J Indian Soc Periodontol ISSN: 0972-124X
Intergroup comparison of implant stability quotient values
| Group |
| Mean±SD | Median | Mann-Whitney U value |
| ||
|---|---|---|---|---|---|---|---|
| ISQ baseline | 1 | 30 | 25.135333±1.260891 | 25.230000 | 425.500 | −4.085 | 0.717# |
| 2 | 30 | 25.059333±2.611289 | 25.305000 | ||||
| ISQ 1 week | 1 | 30 | 50.287000±5.418054 | 51.140000 | 288.000 | −2.398 | 0.016* |
| 2 | 30 | 46.847000±6.437912 | 47.415000 | ||||
| ISQ 1 month | 1 | 30 | 59.564667±4.510371 | 59.675000 | 296.00 | −2.278 | 0.023* |
| 2 | 30 | 57.127667±3.829209 | 56.500000 | ||||
| ISQ 3 months | 1 | 30 | 67.784000±6.106217 | 69.140000 | 414.000 | −0.533 | 0.594# |
| 2 | 30 | 69.926900±3.566833 | 70.065000 |
#Nonsignificant difference (P>0.05); *Statistically significant difference (P<0.05). Z – Z value for nonparametric test utilizing Mann-Whitney U-test of intergroup comparison; ISQ – Implant stability quotient; n – Number of surgical sites; P – Probability value; SD – Standard deviation
Intragroup comparison in Group 1 using Friedman’s test
|
| Mean±SD | Minimum | Maximum | Median | Mean rank |
| ||
|---|---|---|---|---|---|---|---|---|
| ISQ baseline | 30 | 25.13533±1.260891 | 23.2200 | 27.1200 | 25.23000 | 1.00 | 87.760 | 0.000** |
| ISQ 1 week | 30 | 50.28700±5.418054 | 40.0000 | 59.2300 | 51.14000 | 2.00 | ||
| ISQ 1 month | 30 | 59.56466±4.510371 | 48.5000 | 67.7300 | 59.67500 | 3.07 | ||
| ISQ 3 months | 30 | 67.78400±6.106217 | 57.9000 | 77.2300 | 69.14000 | 3.93 |
**Statistically highly significant difference (P<0.01). ISQ – Implant stability quotient; n – Number of surgical sites; P – Probability value; SD – Standard deviation; χ2 – Chi Square
Intragroup comparison in Group 2 using Friedman’s test
|
| Mean±SD | Minimum | Maximum | Median | Mean rank |
| ||
|---|---|---|---|---|---|---|---|---|
| ISQ baseline | 30 | 25.05933±2.6112897 | 20.1100 | 29.8700 | 25.3050 | 1.00 | 90.000 | 0.000** |
| ISQ 1 week | 30 | 46.84700±6.4379126 | 34.7000 | 58.7300 | 47.4150 | 2.00 | ||
| ISQ 1 month | 30 | 57.12766±3.8292096 | 52.2300 | 68.2300 | 56.5000 | 3.00 | ||
| ISQ 3 months | 30 | 69.92690±3.5668332 | 63.3500 | 77.1300 | 70.0650 | 4.00 |
**Statistically highly significant difference (P<0.01). ISQ – Implant stability quotient; P – Probability value; SD – Standard deviation; χ2 – Chi Square; n – Number of surgical sites
Pairwise intragroup comparison in Group 1 using Wilcoxon signed-rank test
| Time pairs |
| |
|---|---|---|
| ISQ 1 week-ISQ baseline | −4.786 | 0.000** |
| ISQ 1 month-ISQ baseline | −4.786 | 0.000** |
| ISQ 3 month-ISQ baseline | −4.786 | 0.000** |
| ISQ 1 month-ISQ 1 week | −5.150 | 0.000** |
| ISQ 3 months-ISQ 1 week | −5.260 | 0.000** |
| ISQ 3 months-ISQ 1 month | −5.083 | 0.000** |
**Statistically highly significant difference (P<0.01). Z – Z value for nonparametric test utilizing Wilcoxon signed-rank test of pairwise comparison; ISQ – Implant stability quotient; P – Probability value
Pairwise intragroup comparison in Group 2 using Wilcoxon signed-rank test
| Time pairs |
| |
|---|---|---|
| ISQ 1 week-ISQ baseline | −4.782 | 0.000** |
| ISQ 1 month-ISQ baseline | −4.782 | 0.000** |
| ISQ 3 month-ISQ baseline | −4.782 | 0.000** |
| ISQ 1 month-ISQ 1 week | −4.810 | 0.000** |
| ISQ 3 months-ISQ 1 week | −4.787 | 0.000** |
| ISQ 3 months-ISQ 1 month | −4.784 | 0.000** |
**Statistically highly significant difference (P<0.01). Z – Z value for nonparametric test utilizing Wilcoxon signed-rank test of pairwise comparison; ISQ – Implant stability quotient; P – Probability value