Literature DB >> 26631300

Cone-beam Computed Tomography for Detecting Vertical Root Fractures in Endodontically Treated Teeth: A Systematic Review.

Edwin Chang1, Ernest Lam1, Prakesh Shah2, Amir Azarpazhooh3.   

Abstract

INTRODUCTION: A vertical root fracture (VRF), commonly found in teeth with endodontic treatment, is challenging to diagnose and has poor treatment outcomes. Cone-beam computed tomography (CBCT) has become an increasingly popular imaging modality in endodontics, but image artifacts arising from root-filling materials may hinder VRF detection. The aim of this investigation was to conduct a systematic review to assess the diagnostic ability of CBCT for detecting VRFs in endodontically treated teeth.
METHODS: A systematic review of in vivo clinical diagnostic literature (initial search December 2014, updated August 2015) was conducted. Assessment of methodological quality was performed by using the modified Quality Assessment of Diagnostic Accuracy Studies tool.
RESULTS: Four studies with a total of 130 patients were included. The reported ranges of values were 40%-90% for VRF prevalence, 84% (0.64-0.95) to 100% (0.83-1.00) for sensitivity, 64% (0.35-0.87) to 100% (0.03-1.00) for specificity, 71% (0.51-0.87) to 100% (0.63-1.00) for positive predictive value, and 50% (0.01-0.99) to 100% (0.84-1.00) for negative predictive value. All 4 studies revealed multiple items at high risk or unclear risk of bias.
CONCLUSIONS: Because of the significant imprecision in the range of reported estimates and the biases observed in the included studies, there is currently insufficient evidence to suggest that CBCT is a reliable test in detecting VRFs in endodontically treated teeth.
Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cone beam computed tomography; diagnosis; review literature as topic; tooth fractures

Mesh:

Year:  2015        PMID: 26631300     DOI: 10.1016/j.joen.2015.10.005

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  25 in total

1.  Application of image processing techniques to aid in the detection of vertical root fractures in digital periapical radiography.

Authors:  Lucas Exposto Soares; Deborah Queiroz Freitas; Kaique Leite de Lima; Lorena Rosa Silva; Fernanda Paula Yamamoto-Silva; Marcelo Andrade da Costa Vieira
Journal:  Clin Oral Investig       Date:  2021-02-05       Impact factor: 3.573

Review 2.  Radiation dose in non-dental cone beam CT applications: a systematic review.

Authors:  Cosimo Nardi; Sergio Salerno; Roberto Molteni; Mariaelena Occhipinti; Giulia Grazzini; Niccolò Norberti; Cesare Cordopatri; Stefano Colagrande
Journal:  Radiol Med       Date:  2018-06-05       Impact factor: 3.469

3.  Metallic materials in the exomass impair cone beam CT voxel values.

Authors:  Amanda P Candemil; Benjamin Salmon; Deborah Q Freitas; Glaucia Mb Ambrosano; Francisco Haiter-Neto; Matheus L Oliveira
Journal:  Dentomaxillofac Radiol       Date:  2018-03-27       Impact factor: 2.419

4.  Microsurgical re-treatment of an endodontically treated tooth with an apically located incomplete vertical root fracture: a clinical case report.

Authors:  Silvio Taschieri; Massimo Del Fabbro; Ahmed El Kabbaney; Igor Tsesis; Eyal Rosen; Stefano Corbella
Journal:  Restor Dent Endod       Date:  2016-06-21

5.  Are metal artefact reduction algorithms effective to correct cone beam CT artefacts arising from the exomass?

Authors:  Amanda Pelegrin Candemil; Benjamin Salmon; Deborah Queiroz Freitas; Glaucia Maria Bovi Ambrosano; Francisco Haiter-Neto; Matheus Lima Oliveira
Journal:  Dentomaxillofac Radiol       Date:  2019-01-28       Impact factor: 2.419

Review 6.  Radiographic diagnosis of root fractures: a systematic review, meta-analyses and sources of heterogeneity.

Authors:  Fernanda Cristina Sales Salineiro; Solange Kobayashi-Velasco; Mariana Minatel Braga; Marcelo Gusmão Paraiso Cavalcanti
Journal:  Dentomaxillofac Radiol       Date:  2017-11-02       Impact factor: 2.419

7.  Influence of the exomass on the detection of simulated root fracture in cone-beam CT - an ex-vivo study.

Authors:  Amanda Pelegrin Candemil; Francesca Mangione; Karla Farias Vasconcelos; Anne Caroline Oenning; Reinhilde Jacobs; Deborah Queiroz Freitas; Francisco Haiter-Neto; Benjamin Salmon; Matheus Lima Oliveira
Journal:  Dentomaxillofac Radiol       Date:  2020-12-11       Impact factor: 2.419

8.  CBCT image artefacts generated by implants located inside the field of view or in the exomass.

Authors:  Husniye Demirturk Kocasarac; Lisa J Koenig; Gulbahar Ustaoglu; Matheus Lima Oliveira; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2021-07-29       Impact factor: 2.419

Review 9.  Two decades of research on CBCT imaging in DMFR - an appraisal of scientific evidence.

Authors:  Hugo Gaêta-Araujo; André Ferreira Leite; Karla de Faria Vasconcelos; Reinhilde Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2021-02-15       Impact factor: 2.419

10.  In vivo detection of vertical root fractures in endodontically treated teeth: Accuracy of cone-beam computed tomography and assessment of potential predictor variables.

Authors:  Marcela Quintero-Álvarez; Leslie-Melissa Bolaños-Alzate; Paula-Andrea Villa-Machado; Felipe-Augusto Restrepo-Restrepo; Sergio-Iván Tobón-Arroyave
Journal:  J Clin Exp Dent       Date:  2021-02-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.