| Literature DB >> 35268527 |
Juan Ramón González Rueda1, Irene García Ávila1, Víctor Manuel de Paz Hermoso2, Elena Riad Deglow1, Álvaro Zubizarreta-Macho1,3, Jesús Pato Mourelo4, Javier Montero Martín3, Sofía Hernández Montero1.
Abstract
The objective of this in vitro study was to evaluate and compare the accuracy of zygomatic dental implant (ZI) placement carried out using a dynamic navigation system.Entities:
Keywords: computer-aided surgery; image-guided surgery; implantology; navigation system; zygomatic implants
Year: 2022 PMID: 35268527 PMCID: PMC8910948 DOI: 10.3390/jcm11051436
Source DB: PubMed Journal: J Clin Med ISSN: 2077-0383 Impact factor: 4.241
Figure 1Preoperative planning of ZI placement based on the CBCT scan taken of the patient. Detail of the coronal, sagittal, and axial views, and three-dimensional reconstruction.
Figure 2(A) Polyurethane model fixed onto an artificial head and (B) drilling procedure.
Figure 3(A) Preoperative planning of placement of ZIs with the dynamic navigation appliance using treatment-planning software, and (B) tracking procedure during ZI placement.
Figure 4(A) CBCT images of the coronal, sagittal, and axial views; and (B) front and (C) bottom views of the three-dimensional reconstruction of the measurement procedure contrasted against the preoperative planning (green cylinders) and postoperative ZI placement (blue cylinders) of the ZIs placed on the experimental model.
Descriptive values of deviations at the coronal entry point (mm), apical end point (mm), and angular (°) deviations of the computer-aided dynamic navigation technique (NI) and the free-hand approach.
|
| Mean | Median | SD | Lower 95% CL for Mean | Upper 95% CL for Mean | Minimum | Maximum | ||
|---|---|---|---|---|---|---|---|---|---|
| CORONAL | NI | 19 | 5.43 a | 5.70 | 2.13 | 4.41 | 6.46 | 1.60 | 10.50 |
| FHI | 20 | 4.75 a | 4.35 | 1.58 | 4.01 | 5.48 | 2.20 | 7.80 | |
| APICAL | NI | 19 | 4.92 a | 4.70 | 1.89 | 4.00 | 5.83 | 1.70 | 9.10 |
| FHI | 20 | 3.20 b | 3.30 | 1.45 | 2.52 | 3.88 | 0.60 | 5.40 | |
| ANGULAR | NI | 19 | 7.36 a | 6.20 | 4.12 | 5.37 | 9.34 | 0.90 | 16.10 |
| FHI | 20 | 8.47 b | 7.05 | 4.40 | 6.41 | 10.53 | 3.50 | 17.20 |
a,b Statistically significant differences (p < 0.05) found between groups. NI: navigation implants; and FHI: free-hand implants.
Figure 5Box plot of deviations at the coronal entry point observed in the study groups and ZI positions. Median values are represented by the horizontal lines within each box. The symbols represent extreme values.
Figure 6Box plot of apical end-point deviations recorded in the study groups and ZI positions. Median values are represented by the horizontal lines within each box. The symbols represent extreme values.
Figure 7Box plot of angular deviations found in the study groups and ZI positions. Median values are represented by the horizontal lines within each box. The symbols represent extreme values.