Literature DB >> 16117776

Accuracy of image-guided implantology.

Jakob Brief1, Dieter Edinger, Stefan Hassfeld, Georg Eggers.   

Abstract

OBJECTIVES: The accuracy of two commercially available systems for image-guided dental implant insertion based on infrared tracking cameras was compared with manual implantation.
MATERIAL AND METHODS: Phantoms of partially edentulous mandibles were used. In a master phantom, pilot boreholes for dental implants were placed. These boreholes were reproduced in slave phantoms using either of the two image-guided systems and manual implantation. The resulting positions were determined using a coordinate measurement machine and compared with the master model.
RESULTS: In comparison with manual implantation, the difference of borehole positions to the master phantom was significantly lower using either of the systems for image-guided implant insertion.
CONCLUSION: Image-guided insertion of dental implants is significantly more accurate than manual insertion. However, the accuracy that can be achieved with manual implantation is sufficient for most clinical situations.

Mesh:

Year:  2005        PMID: 16117776     DOI: 10.1111/j.1600-0501.2005.01133.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  22 in total

1.  Oral Implant Imaging: A Review.

Authors:  Sarika Gupta; Neelkant Patil; Jitender Solanki; Ravinder Singh; Sanjeev Laller
Journal:  Malays J Med Sci       Date:  2015 May-Jun

Review 2.  Flapless dental implant surgery and use of cone beam computer tomography guided surgery.

Authors:  D P Laverty; J Buglass; A Patel
Journal:  Br Dent J       Date:  2018-04-06       Impact factor: 1.626

3.  Evaluation of accuracy in implant site preparation performed in single- or multi-step drilling procedures.

Authors:  Nadine Marheineke; Uta Scherer; Martin Rücker; Constantin von See; Björn Rahlf; Nils-Claudius Gellrich; Marcus Stoetzer
Journal:  Clin Oral Investig       Date:  2017-12-17       Impact factor: 3.573

4.  Challenges in image-guided therapy system design.

Authors:  Simon Dimaio; Tina Kapur; Kevin Cleary; Stephen Aylward; Peter Kazanzides; Kirby Vosburgh; Randy Ellis; James Duncan; Keyvan Farahani; Heinz Lemke; Terry Peters; William Bill Lorensen; David Gobbi; John Haller; Laurence Larry Clarke; Stephen Pizer; Russell Taylor; Robert Galloway; Gabor Fichtinger; Nobuhiko Hata; Kimberly Lawson; Clare Tempany; Ron Kikinis; Ferenc Jolesz
Journal:  Neuroimage       Date:  2007-04-24       Impact factor: 6.556

5.  Accuracy of Computer-Assisted Dynamic Navigation in Implant Placement with a Fully Digital Approach: A Prospective Clinical Trial.

Authors:  Cornelia Edelmann; Martin Wetzel; Anne Knipper; Ralph G Luthardt; Sigmar Schnutenhaus
Journal:  J Clin Med       Date:  2021-04-21       Impact factor: 4.241

6.  Image-guided surgery and medical robotics in the cranial area.

Authors:  G Widmann
Journal:  Biomed Imaging Interv J       Date:  2007-01-01

Review 7.  Surgical templates for dental implant positioning; current knowledge and clinical perspectives.

Authors:  Mohammed Zaheer Kola; Altaf H Shah; Hesham S Khalil; Ahmed Mahmoud Rabah; Nehad Mohammed H Harby; Seham Ali Sabra; Deepti Raghav
Journal:  Niger J Surg       Date:  2015 Jan-Jun

Review 8.  Computerized implant-dentistry: Advances toward automation.

Authors:  Minkle Gulati; Vishal Anand; Sanjeev Kumar Salaria; Nikil Jain; Shilpi Gupta
Journal:  J Indian Soc Periodontol       Date:  2015 Jan-Feb

9.  In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants.

Authors:  Young-June Huh; Bo-Ram Choi; Kyung-Hoe Huh; Won-Jin Yi; Min-Suk Heo; Sam-Sun Lee; Soon-Chul Choi
Journal:  Imaging Sci Dent       Date:  2012-09-21

10.  Implant surgical guides: From the past to the present.

Authors:  Manikandan Ramasamy; Ramesh Raja; Rachuri Narendrakumar
Journal:  J Pharm Bioallied Sci       Date:  2013-06
View more