Literature DB >> 3522637

Comparison of radiometric and gas capture system for blood cultures.

A King, G Bone, I Phillips.   

Abstract

A single bottle blood culture system that detects the gas produced by micro-organisms from substrates in a specially formulated medium was compared with the Bactec radiometric system. A total of 725 blood samples collected from patients with suspected bacteraemia yielded 75 clinically important isolates. Fifty five (73%) of these cultures were detected by both methods, 16 (21%) by only the Bactec system, and four (5%) by only the Oxoid system. No significant differences were found between the two systems after allowance was made for the different volume of sample inoculated into each system.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3522637      PMCID: PMC499986          DOI: 10.1136/jcp.39.6.661

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  1 in total

1.  Automated radiometric detection of bacteria in 2,967 blood cultures.

Authors:  H J DeBlanc; F DeLand; H N Wagner
Journal:  Appl Microbiol       Date:  1971-11
  1 in total
  9 in total

1.  Detection of bacteria in blood by centrifugation and filtration.

Authors:  M Bernhardt; D R Pennell; L S Almer; R F Schell
Journal:  J Clin Microbiol       Date:  1991-03       Impact factor: 5.948

Review 2.  Blood cultures: where do we stand?

Authors:  R C Spencer
Journal:  J Clin Pathol       Date:  1988-06       Impact factor: 3.411

3.  Evaluation of use of Signal system of blood culture in paediatrics.

Authors:  H Fox; D E Healing; R H George
Journal:  J Clin Pathol       Date:  1988-06       Impact factor: 3.411

4.  Comparison of conventional and single bottle system for blood cultures.

Authors:  J A Wilson; A J Barratt; J Gray; G B Statham
Journal:  J Clin Pathol       Date:  1988-06       Impact factor: 3.411

5.  Rapid identification of bacterial antigen in blood cultures and cerebrospinal fluid.

Authors:  R G Williams; C A Hart
Journal:  J Clin Pathol       Date:  1988-06       Impact factor: 3.411

6.  Comparison of five tests used in diagnosis of neonatal bacteraemia.

Authors:  P Kite; M R Millar; P Gorham; P Congdon
Journal:  Arch Dis Child       Date:  1988-06       Impact factor: 3.791

7.  Comparison of radiometric and gas capture systems for blood cultures.

Authors:  E A Harper; A S Jones
Journal:  J Clin Pathol       Date:  1987-02       Impact factor: 3.411

8.  SIGNAL blood culture system for detection of bacteremia in neonates.

Authors:  C Trombley; J D Anderson
Journal:  J Clin Microbiol       Date:  1987-11       Impact factor: 5.948

9.  Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia.

Authors:  M P Weinstein; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1988-05       Impact factor: 5.948

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.