In the SIGNAL (Oxoid Ltd., Basingstoke, United Kingdom) blood culture system, gas produced by bacterial metabolism displaces medium from the culture bottle into an upper reservoir via a hollow needle. Displacement of media may provide a visual indication of the presence of both aerobic and anaerobic organisms in a single medium. The single-bottle SIGNAL system was compared with paired BACTEC 16B and 7D (Johnston Laboratories, Inc., Towson, Md.) radiometric system bottles by using bacterial inocula and conditions which simulated those found in neonatal and pediatric populations. The single SIGNAL bottle was a good as the combined BACTEC media for Escherichia coli and Staphylococcus aureus, but was slower for Candida spp., Haemophilus influenzae, Pseudomonas aeruginosa, Staphylococcus epidermidis, group B streptococci, alpha-streptococci, and pneumococci. The SIGNAL system failed to detect four of five isolates of Neisseria meningitidis and four of eight anaerobic organisms. The SIGNAL system is not suitable for neonatal blood cultures at its present state of development.

Entities:  

Mesh:

Year:  1987        PMID: 3320080      PMCID: PMC269419          DOI: 10.1128/jcm.25.11.2098-2101.1987

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  9 in total

1.  Novel method for detecting micro-organisms in blood cultures.

Authors:  D Sawhney; S Hinder; D Swaine; E Y Bridson
Journal:  J Clin Pathol       Date:  1986-11       Impact factor: 3.411

2.  Volume of blood submitted for culture from neonates.

Authors:  P R Neal; M B Kleiman; J K Reynolds; S D Allen; J A Lemons; P L Yu
Journal:  J Clin Microbiol       Date:  1986-09       Impact factor: 5.948

3.  Neonatal Escherichia coli septicemia--bacterial counts in blood.

Authors:  D E Dietzman; G W Fischer; F D Schoenknecht
Journal:  J Pediatr       Date:  1974-07       Impact factor: 4.406

4.  Incubation period necessary to detect bacteremia in neonates.

Authors:  A H Rowley; E R Wald
Journal:  Pediatr Infect Dis       Date:  1986 Sep-Oct

Review 5.  Assessment of anemia in newborn infants.

Authors:  V S Blanchette; A Zipursky
Journal:  Clin Perinatol       Date:  1984-06       Impact factor: 3.430

6.  Clinical comparison of the Isolator 1.5 microbial tube and the BACTEC radiometric system for detection of bacteremia in children.

Authors:  R B Carey
Journal:  J Clin Microbiol       Date:  1984-05       Impact factor: 5.948

7.  Comparison of radiometric and gas capture system for blood cultures.

Authors:  A King; G Bone; I Phillips
Journal:  J Clin Pathol       Date:  1986-06       Impact factor: 3.411

8.  Routine quantitative blood cultures in children with Haemophilus influenzae or Streptococcus pneumoniae bacteremia.

Authors:  L M Bell; G Alpert; J M Campos; S A Plotkin
Journal:  Pediatrics       Date:  1985-12       Impact factor: 7.124

9.  Relationship between the magnitude of bacteremia in children and the clinical disease.

Authors:  T D Sullivan; L J LaScolea; E Neter
Journal:  Pediatrics       Date:  1982-06       Impact factor: 7.124

  9 in total
  8 in total

1.  Assessment of the BACTEC NR660 blood culture system for the detection of bacteremia in young children.

Authors:  J D Anderson; C Trombley; N Cimolai
Journal:  J Clin Microbiol       Date:  1989-04       Impact factor: 5.948

2.  SIGNAL blood culture system in clinical practice.

Authors:  E B Kaczmarski; G J Roberts
Journal:  J Clin Microbiol       Date:  1988-07       Impact factor: 5.948

Review 3.  Fungal blood cultures.

Authors:  A Telenti; G D Roberts
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

Review 4.  Detection of bloodstream infections in children.

Authors:  J M Campos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

5.  Comparison of the Oxoid Signal blood culture system with supplemented peptone broth in a pediatric hospital.

Authors:  C A Himmelreich; M F Orlando; G A Storch
Journal:  J Clin Microbiol       Date:  1989-06       Impact factor: 5.948

6.  Comparative evaluation of nonradiometric BACTEC and improved oxoid signal blood culture systems in a clinical laboratory.

Authors:  C Daley; I Lim; J Modra; I Wilkinson
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

Review 7.  Laboratory diagnosis of invasive candidiasis.

Authors:  J M Jones
Journal:  Clin Microbiol Rev       Date:  1990-01       Impact factor: 26.132

8.  Comparative evaluation of the oxoid signal and Roche Septi-Chek blood culture systems.

Authors:  P R Murray; A C Niles; R L Heeren; M M Curren; L E James; J E Hoppe-Bauer
Journal:  J Clin Microbiol       Date:  1988-12       Impact factor: 5.948

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.