Literature DB >> 3290274

Evaluation of use of Signal system of blood culture in paediatrics.

H Fox1, D E Healing, R H George.   

Abstract

A new method of blood culture, the Signal system (Oxoid), was assessed in paediatric practice. Isolation rates of pathogens, frequency of contamination (false positive results), and time taken to detect positive cultures were analysed. Four hundred and seventy nine organisms were isolated from 457 of 3000 cultures collected, of which 283 organisms were considered to be clinically important. The overall rate of positive cultures was 15.2%, and clinically important organisms were isolated from 9.1%, giving an overall contamination rate of 6.1%. The rate of contamination with Gram positive bacilli was 1.1% and coagulase negative staphylococci 4.2%. Over 51.6% of all isolates were detected within 24 hours, 81% within 48 hours, and 86% within three days: 91.1% of clinically important organisms were isolated within three days. Unimportant organisms tended to give a delayed signal, although this sometimes occurred with Candida spp, Klebsiella spp, Pseudomonas spp and a small number of other such organisms. Four hundred and forty nine of the 457 positive cultures gave a visible signal. Six of seven isolates of Haemophilus influenzae failed to give a signal, as did two coagulase negative staphylococci. The Signal system is a convenient and cost effective method of blood culture.

Entities:  

Mesh:

Year:  1988        PMID: 3290274      PMCID: PMC1141552          DOI: 10.1136/jcp.41.6.683

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  16 in total

1.  Novel method for detecting micro-organisms in blood cultures.

Authors:  D Sawhney; S Hinder; D Swaine; E Y Bridson
Journal:  J Clin Pathol       Date:  1986-11       Impact factor: 3.411

2.  Quantitative blood cultures in childhood bacteremia.

Authors:  W A Durbin; E G Szymczak; D A Goldmann
Journal:  J Pediatr       Date:  1978-05       Impact factor: 4.406

3.  Contamination of cultures processed with the isolator lysis-centrifugation blood culture tube.

Authors:  R B Thomson; S J Vanzo; N K Henry; K L Guenther; J A Washington
Journal:  J Clin Microbiol       Date:  1984-02       Impact factor: 5.948

4.  Automated detection of micro-organisms in blood cultures by means of the Malthus Microbiological Growth Analyser.

Authors:  D F Brown; M Warner; C E Taylor; R E Warren
Journal:  J Clin Pathol       Date:  1984-01       Impact factor: 3.411

5.  Symposium report blood culture--current state and future prospects. Abstracts.

Authors: 
Journal:  J Clin Pathol       Date:  1983-09       Impact factor: 3.411

6.  Clinical laboratory comparison of lysis-centrifugation and BACTEC radiometric blood culture techniques.

Authors:  J C McLaughlin; P Hamilton; J V Scholes; R C Bartlett
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

7.  Automated radiometric detection of bacteria in 2,967 blood cultures.

Authors:  H J DeBlanc; F DeLand; H N Wagner
Journal:  Appl Microbiol       Date:  1971-11

8.  Improved blood culture technique based on centrifugation: clinical evaluation.

Authors:  G L Dorn; G A Land; G E Wilson
Journal:  J Clin Microbiol       Date:  1979-03       Impact factor: 5.948

9.  Relationship between the magnitude of bacteremia in children and the clinical disease.

Authors:  T D Sullivan; L J LaScolea; E Neter
Journal:  Pediatrics       Date:  1982-06       Impact factor: 7.124

10.  Comparison of the quantitative direct plating method and the BACTEC procedure for rapid diagnosis of Haemophilus influenzae bacteremia in children.

Authors:  L J La Scolea; D Dryja; E Neter
Journal:  J Clin Microbiol       Date:  1981-12       Impact factor: 5.948

View more
  2 in total

Review 1.  Detection of bloodstream infections in children.

Authors:  J M Campos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

2.  Experience of changing between signal and Bactec 9240 blood culture systems in a children's hospital.

Authors:  J Gray; M Brockwell; I Das
Journal:  J Clin Pathol       Date:  1998-04       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.