Literature DB >> 3290273

Comparison of conventional and single bottle system for blood cultures.

J A Wilson1, A J Barratt, J Gray, G B Statham.   

Abstract

A single bottle blood culture system (Oxoid Signal system) was compared with a conventional two bottle subculturing system. A total of 2016 routine blood samples yielded 186 (9%) clinically important isolates. Of these, 40 (21%) were isolated only in the Oxoid system and 30 (17%) only in the conventional system. One hundred and sixteen (62%) were isolated from both systems. Volume of blood was not significantly associated with the rate of detection but was significantly associated with the speed of detection. A continuation of the study with a Signal bottle and single conventional bottle confirmed initial results of the increased isolation rate using two systems. The Oxoid single bottle blood culture system was at least comparable with a conventional system in terms of rate of detection of organisms and was superior in terms of speed of detection.

Entities:  

Mesh:

Year:  1988        PMID: 3290273      PMCID: PMC1141551          DOI: 10.1136/jcp.41.6.679

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  4 in total

1.  Novel method for detecting micro-organisms in blood cultures.

Authors:  D Sawhney; S Hinder; D Swaine; E Y Bridson
Journal:  J Clin Pathol       Date:  1986-11       Impact factor: 3.411

2.  Effect of volume of blood cultured on detection of bacteremia.

Authors:  M M Hall; D M Ilstrup; J A Washington
Journal:  J Clin Microbiol       Date:  1976-06       Impact factor: 5.948

3.  Comparison of radiometric and gas capture system for blood cultures.

Authors:  A King; G Bone; I Phillips
Journal:  J Clin Pathol       Date:  1986-06       Impact factor: 3.411

4.  Controlled evaluation of the volume of blood cultured in detection of bacteremia and fungemia.

Authors:  J H Tenney; L B Reller; S Mirrett; W L Wang; M P Weinstein
Journal:  J Clin Microbiol       Date:  1982-04       Impact factor: 5.948

  4 in total
  2 in total

Review 1.  Contamination of blood cultures during venepuncture: fact or myth?

Authors:  E Shahar; B S Wohl-Gottesman; L Shenkman
Journal:  Postgrad Med J       Date:  1990-12       Impact factor: 2.401

Review 2.  Detection of bloodstream infections in children.

Authors:  J M Campos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.