| Literature DB >> 35221359 |
Jaya Choudhary1, Arijit Kumar Barai1, Sandip Das1, Nirjhar Mukherjee1.
Abstract
BACKGROUND AND AIMS: The role of King Vision videolaryngoscope (KVL) is well known in the anticipated difficult airway. However, its performance in patients with unanticipated restricted view of the glottis has never been investigated. The aim of this study was to evaluate the performance of KVL in patients with limited glottic view (POGO score <50%).Entities:
Keywords: Airway management; endotracheal intubation; laryngoscope
Year: 2021 PMID: 35221359 PMCID: PMC8820336 DOI: 10.4103/ija.ija_905_21
Source DB: PubMed Journal: Indian J Anaesth ISSN: 0019-5049
Patient characteristics
| Age (years) | 44.68±11.338 |
| Height (metres) | 1.67±0.087 |
| Weight (kg) | 71.81±9.421 |
| Gender (M/F) | 33/52 |
| ASA (I/II/III) | 40/44/1 |
Data expressed as mean±standard deviationor numbers; ASA: American Society of Anesthesiologists; M:Male; F:Female
Laryngoscopy pararameters
| MAC | KVL |
| ||||
|---|---|---|---|---|---|---|
| POGO | 20 (0,40) | 90 (40,100) | <0.001* | |||
| CL | II | III | IV | I | II | <0.001* |
| 63 (74.1%) | 17 (20.0%) | 5 (5.9%) | 46 (54.1%) | 39 (45.9%) | ||
| Time taken to obtain the best glottic view | 11.22±3.93 | 15.4±3.61 | <0.001* | |||
Data expressed as median (min, max) or numbers (%), *Statistically significant, MAC: Macintosh Laryngoscope, KVL: King vision videolaryngoscope; CL: Cormack Lehane
Figure 1Boxplot comparing median POGO scores obtained with Macintosh vs KVL. The inner horizontal line within the box represents the median values and the outer horizontal lines represent the minimum and maximum values
Figure 2Comparison of Cormack Lehane grades with Macintosh (II/III/IV: 63/17/5) vs King Vision videolaryngoscope (I/II: 46/39)
Intubation Parameters with KVL
| Time taken to Intubate(s) | 23.04±5.16 | ||
| Time taken for Placement of Endotracheal Tube(s) | 7.67±2.68 | ||
| Intubation Difficulty Score | 0 | 1 | 2 |
| 46 (54.12) | 31 (36.47) | 8 (9.41) | |
Data expressed as mean±standard deviation or numbers (%); KVL: King vision videolaryngoscope