Sina Mohammadi Sadr1, Elham Ahmadi1,2, Masoumeh Hasani Tabatabaei1, Saba Mohammadi3, Faezeh Atri2,4.
Abstract
OBJECTIVES: Restoration fit is one of the prerequisites of clinical durability. It is controversial as to whether computer-assisted design/computer-aided milling (CAD/CAM) or lost-wax fabrication methods result in more fit metal-ceramic crowns. This in-vitro study was conducted to examine the internal fit of porcelain fused to metal crowns fabricated using CAD/CAM and lost-wax techniques during fabrication stages (framework, porcelain, cementation) through digital triple scanning, replica weighting, and observation with electron microscopy.Entities:
Keywords: CAD/CAM; internal fit; lost wax; metal ceramic alloys
Mesh:
Substances:
Year: 2022 PMID: 35187813 PMCID: PMC9209789 DOI: 10.1002/cre2.529
Source DB: PubMed Journal: Clin Exp Dent Res ISSN: 2057-4347
Figure 1Sample prepared for study
Figure 2Triple scanning method for internal fit evaluation
Figure 3Measurement points in triple scanning method; tip of four occlusal surface cusps and midpoints of axial walls
Figure 4Replica weighting method: (a) prepared replica and (b) digital scale
Figure 5Scanning electron microscope analyzing: (a) a sectioned sample and measurement points, (b) internal space in occlusal surface, (c) internal space in axial surface
Mean internal gap of CAD/CAM and lost wax crowns in framework step
| Evaluation method | Study groups | Mean internal gap | Standard deviation |
|
|---|---|---|---|---|
| Replica weighting | CAD/CAM | 0.036 g | 0.012 | .10 |
| Lost wax | 0.044 g | 0.008 | ||
| Triple scanning | CAD/CAM | 44.04 μm | 12.99 | .65 |
| Lost wax | 58.48 μm | 18.18 |
Abbreviation: CAD/CAM, computer‐assisted design/computer‐aided milling.
Mean internal gap of CAD/CAM and Lost wax crowns in porcelain step
| Evaluation method | Study groups | Mean internal gap | Standard deviation |
|
|---|---|---|---|---|
| Replica weighting | CAD/CAM | 0.024 g | 0.005 | <.001 |
| Lost wax | 0.039 g | 0.006 | ||
| Triple scanning | CAD/CAM | 58.27 μm | 29.44 | .44 |
| Lost wax | 49.76 μm | 16.91 |
Abbreviation: CAD/CAM, computer‐assisted design/computer‐aided milling.
Mean internal gap of CAD/CAM and lost wax crowns after cementation
| Evaluation method | Study groups | Mean internal gap | Standard deviation |
|
|---|---|---|---|---|
| Triple scanning | CAD/CAM | 42.75 μm | 4.80 | .28 |
| Lost wax | 40.73 μm | 3.11 | ||
| Scanning electron microscopes | CAD/CAM | 83.88 μm | 55.39 | .67 |
| Lost wax | 74.97 μm | 28.32 |
Abbreviation: CAD/CAM, computer‐assisted design/computer‐aided milling.